H2N9112001: H2INC Doesn't Recognize /BATCH Command-Line Switch

ID Number: Q79157

1.00 | 1.00

MS-DOS | OS/2

buglist1.00

Summary:

PROBLEM ID: H2N9112001

SYMPTOMS

It is documented that H2INC version 1.0, which shipped with

Microsoft Macro Assembler (MASM) versions 6.0, 6.0a, and 6.0b,

recognizes but ignores C 6.0 options that aren't specified as an

H2INC option. However, the /BATCH switch produces the following

error:

fatal error HI1800: '/BATCH' : unrecognized option

This is most prevalent while working in the Microsoft Programmer's

WorkBench (PWB) where the /BATCH switch is added by default to the

compiler switches that H2INC uses when it is called.

STATUS

Microsoft has confirmed this to be a problem in H2INC version 1.0.

We are researching this problem and will post new information here

as it becomes available.

Additional reference words: 1.00 6.00 6.00a 6.00b h2inc