INF: RECHARGE Entry in UPS Section of LANMAN.INI

ID Number: Q76306

2.00

OS/2

Summary:

The following information is a supplement to the description of the

UPS RECHARGE entry on page 232 of the "Microsoft LAN Manager

Administrator's Reference."

The RECHARGE entry sets the number of minutes of recharge time

required for each minute of battery run time (the time when the

uninterruptible power supply [UPS] is on battery power). This entry is

optional, depending on the SIGNALS that are available from the

battery. This entry should be configured based on the power supply

specifications.

If the UPS service cannot detect a low battery signal from the UPS,

the UPS service will compute a power-up time.

More Information:

To cause the UPS service to perform a shutdown (when a power failure

occurs), do either of the following:

1. Configure the UPS service to perform a shutdown after the time

specified by BATTERYTIME by setting the second digit of the SIGNALS

entry to 0 (zero).

-or-

2. Have the UPS service perform a shutdown when it receives a low

battery signal from the UPS (see the UPS specifications for how

much battery time is available when this signal is generated). To

do this, set the second digit of the SIGNALS entry to 1.

Additional reference words: 2.00 1.21 1.30