OleUIChangeSource
Invokes the Change Source dialog box, allowing the user to change the source of a link.
UINT OleUIChangeSource(
LPOLEUICHANGESOURCE lpCS //Pointer to the in-out structure
);
Parameter
-
lpCS
-
[in] Pointer to the in-out OLEUICHANGESOURCE structure for this dialog box.
Return Values
Standard Success/Error Definitions
-
OLEUI_FALSE
-
Unknown failure (unused).
-
OLEUI_SUCCESS
-
No error, same as OLEUI_OK.
-
OLEUI_OK
-
The user pressed the OK button.
-
OLEUI_CANCEL
-
The user pressed the Cancel button.
Standard Field Validation Errors
-
OLEUI_ERR_STANDARDMIN
-
Errors common to all dialog boxes lie in the range OLEUI_ERR_STANDARDMIN to OLEUI_ERR_STANDARDMAX. This value allows the application to test for standard messages in order to display error messages to the user.
-
OLEUI_ERR_STRUCTURENULL
-
The pointer to an OLEUIXXX structure passed into the function was NULL.
-
OLEUI_ERR_STRUCTUREINVALID
-
Insufficient permissions for read or write access to an OLEUIXXX structure.
-
OLEUI_ERR_CBSTRUCTINCORRECT
-
The cbstruct value is incorrect.
-
OLEUI_ERR_HWNDOWNERINVALID
-
The hWndOwner value is invalid.
-
OLEUI_ERR_LPSZCAPTIONINVALID
-
The lpszCaption value is invalid.
-
OLEUI_ERR_LPFNHOOKINVALID
-
The lpfnHook value is invalid.
-
OLEUI_ERR_HINSTANCEINVALID
-
The hInstance value is invalid.
-
OLEUI_ERR_LPSZTEMPLATEINVALID
-
The lpszTemplate value is invalid.
-
OLEUI_ERR_HRESOURCEINVALID
-
The hResource value is invalid.
Initialization Errors
-
OLEUI_ERR_FINDTEMPLATEFAILURE
-
Unable to find the dialog box template.
-
OLEUI_ERR_LOADTEMPLATEFAILURE
-
Unable to load the dialog box template.
-
OLEUI_ERR_DIALOGFAILURE
-
Dialog box initialization failed.
-
OLEUI_ERR_LOCALMEMALLOC
-
A call to LocalAlloc or the standard IMalloc allocator failed.
-
OLEUI_ERR_GLOBALMEMALLOC
-
A call to GlobalAlloc or the standard IMalloc allocator failed.
-
OLEUI_ERR_LOADSTRING
-
Unable to LoadString localized resources from the library.
-
OLEUI_ERR_OLEMEMALLOC
-
A call to the standard IMalloc allocator failed.
Function Specific Errors
-
OLEUI_ERR_STANDARDMAX
-
Errors common to all dialog boxes lie in the range OLEUI_ERR_STANDARDMIN to OLEUI_ERR_STANDARDMAX. This value allows the application to test for standard messages in order to display error messages to the user.
-
OLEUI_CSERR_LINKCNTRNULL
-
The lpOleUILinkContainer value is NULL.
-
OLEUI_CSERR_LINKCNTRINVALID
-
The lpOleUILinkContainer value is invalid.
-
OLEUI_CSERR_FROMNOTNULL
-
The lpszFrom value is not NULL.
-
OLEUI_CSERR_TONOTNULL
-
The lpszTo value is not NULL.
-
OLEUI_CSERR_SOURCEINVALID
-
The lpszDisplayName or nFileLength value is invalid, or cannot retrieve the link source.
-
OLEUI_CSERR_SOURCEPARSEERROR
-
The nFilename value is wrong.
Remarks
The link source is not changed by the Change Source dialog box itself. Instead, it is up to the caller to change the link source using the returned file and item strings. The Edit Links dialog box typically does this for the caller.
QuickInfo
Windows NT: Use version 3.1 or later.
Windows: Use Windows 95 or later.
Windows CE: Unsupported.
Header: Declared in oledlg.h.
Import Library: Included as a resource in oledlg.dll.
See Also
OLEUICHANGESOURCE, OleUIEditLinks, IOleUILinkContainer