The CLUSCTL_NODE_ENUM_PRIVATE_PROPERTIES control code is used to retrieve a list of the private node properties.
Type: | External |
Access: | CLUS_ACCESS_READ |
Input: | None |
Output: | Array of null-terminated Unicode strings with an additional null terminator appended to the last string. |
Global: | CLUS_NOT_GLOBAL |
Modify: | CLUS_NO_MODIFY |
Code: | CLCTL_ENUM_PRIVATE_PROPERTIES |
The properties that are returned in the contents of the lpOutBuffer parameter are of two types: read/write and read-only.
To retrieve values for the read/write properties, call ClusterNodeControl with the CLUSCTL_NODE_GET_PRIVATE_PROPERTIES control code. To update them, use the CLUSCTL_NODE_SET_PRIVATE_PROPERTIES control code. To validate them, use CLUSCTL_NODE_VALIDATE_PRIVATE_PROPERTIES.
The CLUSCTL_NODE_GET_RO_PRIVATE_PROPERTIES control code enables you to retrieve values for the read-only properties.