"name" node does not speak any of our protocols
[Dynamic Data Exchange]
No communication can take place with the specified node because that node is not using any of the protocols used by NetDDE.
Load one of the protocols that NetDDE supports on the specified node.
"name" node selected an invalid protocol: name
[Dynamic Data Exchange]
The computer at the specified node tried to use a protocol that is not supported by NetDDE.
Account Deleted
[Services for Macintosh (SFM)]
The security ID (SID) on the permissions for a Macintosh directory belongs to a user or group account that was deleted through User Manager.
Use the MacFile menu in File Manager to assign a new user or group to the directory.
Account Invalid
[Services for Macintosh (SFM)]
The security ID (SID) on the permissions for a Macintosh directory belongs to a user or group account that was deleted through User Manager.
Use the MacFile menu in File Manager to assign a new user or group to the directory.
Account Unknown
[Services for Macintosh (SFM)]
If the security ID (SID) for user or group permissions for a Macintosh directory are left over from a previous installation of Windows NT Advanced Server, this message is displayed.
Use the MacFile Permissions menu in File Manager to reassign the owner or group permissions to a new account.
address is not a valid default gateway. The service could not be started.
[Netevent]
The IP address specified for the default gateway is invalid.
Use the Network option in Control Panel to correct the default gateway parameter for the TCP/IP protocol. Select TCP/IP protocol and then choose Configure. Restart the computer once you have reconfigured the protocol.
application - OS/2 Subsystem Bound Application Load Failure
[OS/2 Subsystem]
You cannot run this application under the OS/2 subsystem, because it uses an OS/2 API that is not supported by the subsystem. However, you might be able to run it using Forcedos.
After the application terminates, try again using Forcedos.
application : ' name ' is a directory!
[TFTP]
When you use the Tftp command to transfer files from a remote computer to your computer, you cannot specify the directory name as the destination on your local computer. You must use a filename.
Retype the Tftp command, specifying a filename for the local destination instead of a directory.
application : Argument missing after / text
[FINDSTR]
In the Findstr command line, if you specify the c:/, f:/, or /g: switches, they must be followed immediately by some text (a literal string, text pattern, or filename, depending on the switch).
Correct your usage of these switches in the Findstr command line and retry the command. To see what item of text to follow these switches with, type HELP followed by the command line (in this case, Findstr).
application : bad argument text
[TCP/IP]
You specified an invalid Internet (IP) address in the Route command.
Make sure the Internet address arguments are typed correctly, and then retry the Route command.
application : Bad command line
[FINDSTR]
You have entered a bad command. For instance, you may not have specified any strings to search for in the Findstr command line.
To see the correct syntax for the command line, type HELP followed by the command name (in this case, Findstr).
application : bad gateway address address
[TCP/IP]
If you used a network name or alias for the destination parameter in the Route command and you get this message, then the Route command was unable to find the name or alias in the HOSTS file on the local computer (the path to the HOSTS file is \systemroot\system32\drivers\etc). If you used an IP address, you specified an invalid format. For example, you may not have used a dotted decimal form, such as 11.1.12.17.
Make sure the gateway is physically attached to the network adapter that is in your computer (is part of the same subnet). Then retry the Route command, using a valid gateway address.
application : bad port number-- number
[FTP Server]
The port number parameter you used in an Ftp command is not valid.
Retry the command using a different port number.
application : can't establish connection
[TCP/IP]
The TCP/IP utility named at the beginning of the message could not establish a connection with the remote host, either because there is no networking software on the remote computer, the corresponding server is not running on the remote computer, or no route can be found between your computer and the remote computer.
Make sure you are using the right remote host. If so, wait, and then retry the remote command. If you still get this message, ask your network administrator to check the condition of the remote computer and the routers between the two computers.
application : can't establish stderr
[TCP/IP]
The TCP/IP utility cannot establish a stderr connection with a remote host. There may be no networking software on the remote computer, the corresponding server may not be running on the remote computer, or no route can be found between your computer and the remote computer.
Make sure you are trying to use the right remote host. If you are, wait, and then retry the remote command. If you still get this message, ask your network administrator to check the condition of the remote computer and the routers between the two computers.
application : can't open local file ' filename ' unable to open file for read text.
[TFTP]
The TCP/IP utility, Tftp, was transferring a file from your computer to a remote computer, but was unable to open the file on your computer.
Make sure you specified the correct path to the file in the Tftp command, and that you did not mistype it. Also, check that you have permission to read the file. Then, retry the Tftp command.
application : can't read from local file ' filename '
[TFTP]
You specified a file to transfer to a remote computer, but you do not have read access to that particular file.
Ask your system administrator to give you the needed access.
application : Cannot read file list from filename
[FINDSTR]
The Findstr utility was unable to open the file that contains the list of files to search.
Check the Findstr command line and make sure that you specified the correct path and that there are no misspellings. You may need to use File Manager to search for the file. Also, check that you have access rights to the file.
application : Cannot read strings from filename
[FINDSTR]
The Findstr utility was unable to open the file that contains the search strings.
Check the Findstr command line and make sure that you specified the correct path and that there are no misspellings. You may need to use File Manager to search for the file. Also, check that you have access rights to the file.
application : don't know host ' name '
[TFTP]
Your computer cannot resolve the host name you used as a parameter in the Tftp command into a remote network hardware address.
Make sure you typed the parameter correctly in the Tftp command. If you did, there may be several reasons why your computer cannot resolve the remote computer name. Contact your network administrator to sort out the problem.
application : Error reading file filename.
[FINDSTR]
There are probably bad sectors in this file.
Restore the file from a backup copy. Then try again.
Application - FROZEN
[Virtual DOS Machine (VDM)]
This is a status message. For instance, NTVDM might display this message in the title bar of the Command Prompt window when the user minimizes an application while it is displaying a full-screen graphic display. This message reminds the user that as long as the application is minimized, it is not running.
application : No search strings
[FINDSTR]
Probably, in using the Findstr command, you specified a file that is to contain the string(s) to search for, but that file is empty. Or you may not have specified strings to search for in the Findstr command line.
Retry the Findstr command, but this time specify the strings to search for.
application : not a plain file. filename
[FTP Server]
Using the Ftp command, you attempted to retrieve the file named in the message, but the file is either a directory or a special device.
Verify the name of the file you want to retrieve and retry the Ftp command, using that name.
application : Out of memory
[FINDSTR]
The Findstr utility has run out of memory.
Quit some unneeded applications, then retry the Findstr command.
application : Read file failed. (Cannot create file mapping.)
[FINDSTR]
You do not have enough Windows NT quota right now to carry out the Findstr command, which uses memory-mapped files.
This is a dynamic situation. Either wait a few seconds and retry the Findstr command, or quit some unneeded applications which may be using up some of your quota. If you still get this message, you may have to ask your system administrator to increase your quota.
application : remote terminal session not supported
[TCP/IP]
You must specify a command parameter with the Rsh command. Initiating a remote login session by using the Rsh command with no parameter is not supported by Windows NT.
Use the TCP/IP utility, Telnet, to initiate a remote login session. Or, if you just forgot to use the command parameter with the Rsh command, retry the Rsh command.
application : text ignored
[FINDSTR]
You used a switch in the Findstr command line that is not recognized by the Findstr utility. The utility ignored the parameter and went ahead with its task. This can happen if you forget the colon (:) suffix required of some Findstr switches.
To avoid this message in the future, stop using the parameter named in the message. To see which switches are recognized by the Findstr utility, and which ones require the trailing colon, type HELP followed by the command name (in this case, Findstr).
application : tftp/udp: unknown service
[TFTP]
To transfer files to or from a remote computer using the TCP/IP Tftp command, the remote computer must have Ftp server running. It does not.
If you can transfer the files to a different computer, try using it. Similarly, if the files you are getting from the remote computer also reside on another computer, try using it. Otherwise, you will have to contact someone at the remote computer, or your network administrator, to get the Ftp server running on the remote computer.
application : transfer aborted
[TFTP]
The process receiving the file transfer has ended before the file transfer was completed.
Retry the file transfer. If you still get this message, contact your network administrator.
application : unexpected M_PROTO type: code
[TCP/IP]
The Netstat utility was gathering statistics about a protocol (TCP, UDP, or IP) and received a reply that had the wrong format (a format not consistent with the protocol).
No direct user action is necessary. The Netstat utility will continue executing. If you get this message often, ask your network administrator to interpret the protocol type code that is displayed at the end of the message, and take appropriate action.
application : Write error
[FINDSTR]
You may have tried to redirect the output of the Findstr command to a file (from the console) and the disk the file is on is full.
If you must redirect the output of the Findstr command to a disk file, either first delete some unneeded files from the disk or use a different disk when you retry the Findstr command.
application :TLI Error code
[FTP Server] [TCP/IP]
The TCP/IP utility named at the start of the message had a data connection fail due to an unexpected TLI error.
Retry the operation. If you get this message again, contact your network administrator to interpret the meaning of the TLI error code displayed at the end of the message and take corrective action.
application :TLOOK returned code
[FTP Server] [TCP/IP]
The TCP/IP utility named at the start of the message had a data connection fail due to an unexpected event.
Retry the operation. If you still get this message, contact your network administrator to interpret the meaning of the event number that is displayed at the end of the message and take corrective action.
application could not copy all files to the Emergency Repair Disk. One or more configuration file was not found.
[Repair Disk]
The Rdisk utility could not find one or more necessary files in your \<systemroot>\repair directory and therefore could not copy the files to your Emergency Repair Disk. If the SETUP.LOG file is missing, the Emergency Repair Disk is unusable. If any other file is missing, the Emergency Repair Disk might be partially usable.
If SETUP.LOG, DEFAULT.*, SECURITY.*, or SAM.* are missing, reinstall Windows NT because the Rdisk utility cannot recreate these files. If the missing files are SYSTEM.* and/or SOFTWARE.*, run Rdisk to update the repair information and recreate the missing files. Then create the Emergency Repair Disk again.
application could not copy all files to the Emergency Repair Disk. The Emergency Repair Disk is full. The configuration files were saved in your hard disk.
[Repair Disk]
The repair disk might not be usable. During the repair process, use the repair information on the hard disk rather than the repair information on the Emergency Repair Disk.
application could not save all configuration files.
[Repair Disk]
Some of the repair information in your \<systemroot>\repair directory could not be saved to an Emergency Repair disk. A repair disk created after you see this message might not be usable unless you are attempting to repair system files.
application is unable to get configuration information for the selected floppy disk drive.
[Repair Disk]
A hardware problem might be preventing the repair disk from detecting the type of floppy drive on your computer.
Check the Hardware Compatibility List to verify that your floppy drive is compatible with Windows NT. If so, contact the hardware manufacturer. You might also want to contact technical support.
application was unable to format the disk.
[Repair Disk]
The disk is probably bad.
Try again, using a different disk.
application was unable to load required floppy disk operation support.
[Repair Disk]
The dynamic link library that operates on the floppy drive could not be loaded. The system may be corrupted.
Run Setup to repair the system files.
code is not a valid Windows NT network message number.
[Network] Net Message ID: 3871
The specified message number does not represent a Windows NT message.
Check that you typed the correct message number. To see more information about system messages, type NET HELPMSG <message>#, where <message># is the message number or error code.
command : bad destination address address
[TCP/IP]
If you used a network name or alias for the destination parameter in the Route command and you get this message, then the Route command was unable to find the name or alias in the NETWORKS file on the local computer (the path to the NETWORKS file is \systemroot\system32\drivers\etc). If you used an IP address, you specified an invalid format. For example, you may not have used a dotted decimal format, such as 127, 284.122.107, or 284.122.108).
Retry the Route command, specifying a valid destination.
command : internal error - unknown remote command service
[TCP/IP]
Retry the remote command. If you still get this message, contact your technical support group.
computer name is a domain controller of domain name. Focus will be set to domain name.
[User Manager]
You specified a domain controller rather than a domain in the Domain text box of the Select Domain dialog. The domain for which that computer is a controller will be selected.
Choose OK.
computer name is not a valid computer name.
[Network] Net Message ID: 3870
The computer name you specified is invalid.
Check the spelling of the computer name.
computer name received an ICMP error packet on a nonexistent connection. Type text, Code code, Source address, Destination address.
[Netevent]
An endpoint that no longer exists received an ICMP error packet.
No action is needed.
day is not a recognized day of the week.
[Network] Net Message ID: 3760
The day you specified is invalid. Valid days are Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, and Sunday. Valid abbreviations are M, T, W, Th, F, Sa, and Su.
Retype the command using valid names or abbreviations.
drive letter does not contain a tape.
[Backup]
You attempted to back up files to a backup drive that does not contain a tape.
Insert a tape in the specified backup drive, then choose OK.
drive letter has a remembered connection to name. Do you want to overwrite the remembered connection? name : text
[Network]
You have attempted to assign a remote resource to a drive letter or port name that has been used for a different remote resource. The remote resource usually assigned to this driver letter or port name is not currently connected, but there would normally be an attempt to connect to it the next time you log on.
If you want to change the remote resource assigned to this drive letter or port name, choose Yes. To keep the old assignment, choose No, and then assign the new resource to a different drive letter or port name.
drive letter : text failed, error = number
[CD Player]
An internal software error has occurred.
Exit and restart CD Player. If the problem persists, contact your system administrator.
drive letter : text : General Failure!
[CD Player]
A general failure has occurred in CD Player.
Attempt to restart the application. If this message reappears, contact technical support.
drive letter : Device I/O Error!
[CD Player]
An error occurred when CD Player sent a command to the CD-ROM.
Attempt to repeat the operation that you were performing when the message appeared. If the message reappears, restart CD Player.
drive letter : Device Not Ready!
[CD Player]
Your CD-ROM device is not ready.
Make sure that there is a disc in the drive, and that the drive door is closed.
drive letter : Invalid Device Request!
[CD Player]
CD Player does not support your drive. Or CD Player does support the drive, but the CDAUDIO.SYS needs to be enabled. The following are the drives that CD Player supports: NEC®, Denon®, Pioneer®, and Hitachi®.
If your drive is a supported drive, use the Services option in Control Panel to enable CDAUDIO.SYS.
drive letter : No Media in Drive!
[CD Player]
You attempted to use CD Player to read an empty drive.
Insert a valid disc.
drive letter : Sector Not Found!
[CD Player]
CD Player attempted to play something that does not exist on the disc that is currently in the CD-ROM. For example, if you remove a disc, its titles may still appear in the CD Player window. If you insert another disc, then select a title from the first disc and choose Play, CD Player will generate this message.
Exit and restart CD Player.
drive letter : Unrecognized Media!
[CD Player]
You attempted to use CD Player to read a drive that is empty, or that contains damaged disc, or a disk that is not an audio disk.
Insert a valid audio disc, then try again.
file system is not a valid file system
[Convert]
The Convert utility does not support the target file system you specified in the second parameter of the Convert command. In version 1.0 of Windows NT, the only valid target file system for the Convert utility is NTFS.
If you want to convert the drive to the NTFS file system, retype the Convert command and specify NTFS as the target file system. To check the syntax of the Convert command, type HELP CONVERT at the command prompt.
file system is not available for drive letter drives.
[Utilities]
For example, the HPFS file system is not available on floppy disk drives.
Use a different file system.
filename filename Could not expand second filename so as to match first
[File Compare]
The Fc command expanded the wild cards in the second file you specified, but was unable to find a file on the path you specified to use. In other words, no filenames on the path satisfied the wild cards. Therefore, the Fc command did not compare any files.
Retry the command, either using a different path or a different set of wild cards in the second file specification parameter.
filename Invalid time stamp.
[Chkdsk]
The file allocation table stores the time as year, month, day, hour, minute, and second. The minute and second must be less than 60. The hour must be less than 34. The day must be less than 32. And the month must be less than 13.
Contact technical support.
filename Is cross linked on allocation unit number
[Chkdsk]
Two files (or directories) attempted to access the same disk space.
Run the Chkdsk command with the /f switch to fix the problem.
filename : Read file failed. (Cannot map view of file.)
[FINDSTR]
You must be searching for strings in a huge file.
Split the file you are searching into two parts and use the Findstr command separately on each file.
filename Another file already exists by this name. Use a different file name.
[Paintbrush]
You have attempted to save a file under the name of a file that has been previously saved.
Assign a name to the file that has not already been used.
filename Cannot access this file. Check security privileges over the network drive.
[Common Dialog]
You have specified a file that you do not have access to.
Check the privileges on this file and on the directory in which it resides, or ask the administrator to check it for you. The administrator might need to change the permissions on the file or directory so that you have access to it.
filename Cannot access this file. Please verify security privileges on the network drive.
[Common Dialog]
You cannot access this file, probably because you do not have the necessary permissions on the shared directory in which it resides.
Ask the network administrator to make sure you have the necessary permissions on the shared directory that you have assigned this drive letter to. When that is done, try again.
filename Cannot find this file. Either something has happened to the network or possibly the file has been renamed or moved. Do you want to try again?
[Write]
You attempted to open or to save a file that cannot currently be located.
If this message reappears when you try again, make sure that you have specified the correct location and filename for the file. If the file is located on a network share, and the network connection has gone down, wait until the connection is restored, then try again.
filename Cannot find this file. Make sure that the correct path and file name are given.
[Paintbrush]
You attempted to open a file that does not exist in the path that you have specified.
Specify a valid path to the file and a valid filename.
filename Cannot find this file. Please verify that the correct path and filename are given.
[Common Dialog]
Check that the path is correct and complete, and that you have the right filename. Then try again, making sure the path and filename are typed correctly.
filename Cannot read this file. Either something has happened to the network or possibly the file has been renamed or moved.
[Write]
You have attempted an operation on a file that Write can no longer locate.
Make sure that you have specified the correct location and filename. If the file is located on a network share, and the network connection has gone down, wait, then try again.
filename Cannot rename this file. Either something has happened to the network or possibly the file has been renamed or moved.
[Write]
You attempted to rename a file that cannot currently be located.
Make sure that you have specified the correct location and filename. If the file is located on a network share, and the network connection has gone down, wait, then try again.
filename Cannot save this file.
[Cardfile]
You have attempted to save a file that is read-only protected. Or, if MS-DOS is still on your computer, the temporary file setting in your AUTOEXEC.BAT file may be incorrect.
Use the Properties option in File Manager to determine if the file is read-only. If the file is read-only protected, save the current file under a different name. If the file is not read-only protected, exit File Manager, open MS-DOS, and ensure that your AUTOEXEC.BAT file contains both a TEMP and a TMP setting.
filename does not contain file version information.
No action is needed.
filename exists. You can either replace the existing version or use the Save Contents command to save to a different filename. Do you want to replace the existing version?
In Object Packager, you attempted to assign to a package a name that you have already assigned to a package in the current directory.
Assign a unique filename to the package. Or assign the same filename, but save the package to a different directory.
filename File not found. Please verify that the correct path and filename are given.
[Write]
You directed Write to open a file that does not exist in the path that you have specified.
Specify a valid path to the file.
filename File not found. Please verify the correct file name was given.
[Common Dialog]
You specified a file that does not exist. This could be a result of mistyping the filename, or you might have the wrong name for the file, or the file might have been deleted.
Make sure that you have the correct filename and that the file exists. Then try again, making sure you type the name correctly.
filename has been changed. Save this file before closing?
[Backup]
When you change a file, and then attempt to exit the application, Backup presents you with this message.
If you want to save the changed file, choose Yes. If not, choose No.
filename is an invalid font file
[Program Manager]
You must remove the old version of this font before you can install the new version.
Reinstall the font from the disk supplied by the vendor.
filename is an invalid font file.
[Program Manager]
The file you specified does not contain fonts. The file is missing or corrupt.
filename is an invalid TrueType font file
[Program Manager]
You must remove the old version of this font before you can install the new version.
Reinstall the font from the disk supplied by the vendor.
filename is not a program and cannot be associated with a file extension.
[File Manager]
Choose the filename of an application. It will have a file type of .exe, .pif, .com, or .bat.
filename Not able to open this file because the format is not recognized. Create a new file or open a valid bitmap image file.
[Paintbrush]
Paintbrush supports the following formats: PCX, BMP, Monochrome, 16-color, 256-color, and 24-bit. The bitmap that you have attempted to open in Paintbrush is in a format that Paintbrush does not support.
Follow the action specified in the message.
filename Not able to open this file. Make sure that the correct path and file name are given.
[Paintbrush]
You have attempted to open a file that does not exist in the path that you have indicated.
Specify a valid path to the file and a valid filename.
filename Not able to open this file. Make sure that the path and file name are correct.
[Paintbrush]
You have attempted to open a file that does not exist in the path that you have indicated.
Specify a valid path to the file and a valid filename.
filename Not able to save this file. Close one or more files in other applications, and then try again.
[Paintbrush]
There is not enough disk space to save this file.
Delete some files from the disk and try again. Or, save the file to a different disk.
filename Paintbrush cannot load this file because it was created using a version of Windows earlier than 3.0.
[Paintbrush]
Some applications were designed for previous versions of Windows and do not work correctly with Windows 3.0 and later. In addition, files created in these older applications may not perform reliably or at all in Windows 3.1 or Windows NT.
No action is needed.
filename The above file name is invalid.
[Common Dialog]
The filename does not meet the criteria for a valid filename.
Try again, using a valid filename. Filenames can contain any uppercase or lowercase characters except the following: ? " / \ < > * | :
filename The image has changed. Do you want to save current changes?
[Paintbrush]
You have changed a Paintbrush image, and have attempted to exit the Paintbrush file before saving it.
If you want to save your changes to the Paintbrush file, select Yes. If not, select No. If you want to return to the Paintbrush image, select Cancel.
filename This document has changed. Save current changes?
[Write]
Any time that you change a Write file, Write displays this confirmation message.
If you want to save the current file, choose Yes. If not, choose No. To return to the document, choose Cancel.
filename This file exists and is read-only. Use a different filename.
[Common Dialog]
Saving the file with this filename would overwrite the existing file. However, since the file has Read Only permissions, you cannot overwrite it.
Try again, specifying a different filename.
filename This file exists with Read Only attributes. Please use a different file name.
[Common Dialog]
Saving the file with this filename would overwrite the existing file. However, since the file has Read Only permissions, you cannot overwrite it.
Try again, specifying a different filename.
filename This file is already in use. Select a new name or close the file in use by another application.
[Common Dialog]
Go to the window that was used to open the file, and close the file from there. Then try again.
filename This file is already in use. Use a new filename or close the file in use by another application.
[Common Dialog]
Go to the window that was used to open the file, and close the file from there. Then try again.
filename This file is in use. Use a new filename or close the file in use by another application.
[Write]
You have attempted to save a Write file that is being used by another application.
Close the application that is using the file, then try again to save the file. Or save the file to a new filename.
filename This file is not in the correct format for use with Paintbrush. Create a new file or open a valid bitmap image file.
[Paintbrush]
The file was created by a different application, or the file is corrupt. It might be that the file was simply renamed to have a .BMP extension, but was not converted to a bitmap image file.
If the file was created by a different application, use that application to work with the file. You might be able to save the file as a bitmap image file from within that application.
filename This file is on a network drive with create but no modify privileges. Ask the administrator of this network to change this condition.
[Common Dialog]
In order to make any changes to files in this shared directory, you must have Change or Full Control permission on the directory. You do not have such permissions on this shared directory.
Ask the administrator to set the permissions to allow you to modify this file.
filename This file name is not valid.
[Paintbrush]
When saving a file to a FAT volume, you are permitted to assign to Paintbrush images filenames no longer than eight characters. In addition, you can only assign a Paintbrush image a .BMP or a .PCX extension.
Double-check the name that you have assigned your Paintbrush image. If the filename is longer than eight letters, shorten it or change it altogether. If the extension is not .BMP or .PCX, assign one of these extensions to it.
filename This filename is not valid.
[Write]
If you are saving a file to a FAT volume, filenames must be no longer than eight characters long with a three character extension. The filename that you typed does not follow these specifications. Or you have typed a filename that contains a space or illegal characters.
Type a valid filename that contains only alphanumeric characters.
filename This filename is not valid.
[Common Dialog]
The filename does not meet the criteria for a valid filename.
Try again, using a valid filename. Filenames can contain any uppercase or lowercase characters except the following: ? " / \ < > * | :
filename.EXE - No Disk
[OS/2 Subsystem]
There is no disk in the drive.
Insert a disk in the drive and try again.
filename.EXE - Write Protect Error
[OS/2 Subsystem]
The disk cannot be written to because it is write protected.
Remove the right protection from the disk and try again.
group is a global group. Global groups cannot be created or edited in Low Speed Connection mode.
[User Manager]
Clear Low Speed Connection in the Options menu and try again. If the physical connection to this computer does not support a high speed connection, you might need to go to that computer to create the global group. Or, edit the individual user accounts to add users to or remove users from this group.
name Directory has non-zero file size.
[Chkdsk]
The specified directory entry is corrupt. The entry claims to be a directory, but has a non-zero file size. This state is not valid for a FAT directory entry.
No action is needed.
name Unrecognized EA handle.
[Chkdsk]
The extended attribute handle in the directory entry is invalid and will be zeroed out.
No action is needed.
name : A required parameter is missing from the Registry.
[Netevent]
The driver parameters are invalid.
Reinstall the driver using the Network option in Control Panel.
name : Could not allocate the resources necessary for operation.
[Netevent]
The network driver could not allocate the necessary resources, usually memory, for operation.
Remove some memory-intensive adapters or install more memory.
name : Could not connect to the interrupt number supplied.
[Netevent]
The network driver tried to connect to an interrupt that is in use by another device or adapter card.
Use Network in Control Panel to change the jumpers of your adapter card or run the configuration utility that was supplied with the adapter. See your system administrator if you need assistance.
name : Could not find an adapter.
[Netevent]
The network driver could not find the adapter.
Contact your system administrator. Check the configuration of the adapter card by selecting Network in Control Panel. Make sure the adapter card is configured according to the manufacturer's specifications and that the adapter card's configuration does not conflict with the configurations of other hardware.
name : Does not support the configuration supplied.
[Netevent]
The parameters given to the driver are invalid.
Use Network in Control Panel to remove and then reinstall the driver. If you continue to see this error message, contact technical support.
name : Has determined that the adapter is not functioning properly.
[Netevent]
The network driver received an invalid response from the adapter.
No action is needed. However, if you see this message frequently, ask your system administrator to make sure that the adapter card is configured properly and that its configuration does not conflict with the configurations of other hardware.
name : Has encountered a conflict in resources and could not load.
[Netevent]
The network driver failed to initialize due to an apparent conflict between the adapter card and some other hardware.
Contact your system administrator. Check the configuration of the adapter card by selecting Network in Control Panel. Make sure the adapter card is configured according to the manufacturer's specifications and that the configuration does not conflict with the configurations of other hardware.
name : Has encountered an internal error and has failed.
[Netevent]
The network driver encountered a fatal error and terminated.
Contact your system administrator. Your administrator should verify that the adapter is configured properly and that the adapter card's configuration does not conflict with the configurations of other hardware. Your administrator may want to replace your adapter card if this error message occurs frequently.
name : Has encountered an invalid network address.
[Netevent]
The network address for the adapter card is not configured properly.
Ask your system administrator to reconfigure your card.
name : The adapter has returned an invalid value to the driver.
[Netevent]
The adapter responded incorrectly to the driver.
Check the configuration of the adapter. If you see this message frequently, the adapter card may need to be replaced.
name : The adapter is configured such that the receive space is smaller than the maximum packet size. Some packets may be lost.
[Netevent]
Due to the space limitations of the adapter, your computer cannot use the full capabilities of the network.
If possible, your system administrator may reconfigure the adapter card either to use more memory or to use memory more effectively. Otherwise, no action is needed.
name : The adapter is disabled. The driver cannot open the adapter.
[Netevent]
The adapter is not enabled.
Contact your system administrator to run the adapter's configuration utility and then enable the adapter. Contact the vendor of the adapter if this does not correct the problem.
name : The I/O base address supplied does not match the jumpers on the adapter.
[Netevent]
The base address supplied in the Network option of Control Panel does not match the adapter card settings.
Contact your system administrator. Your administrator should verify that the adapter card is configured properly and that the card's configuration does not conflict with the configurations of other hardware. Your administrator may want to replace your adapter card if this error message occurs frequently.
name : The version number is incorrect for this driver.
[Netevent]
The network driver version number is incompatible with this operating system.
Contact the vendor to replace the network driver.
name : There is a interrupt conflict at interrupt number number.
[Netevent]
The network driver tried to connect to the specified interrupt which is in use by another device or adapter.
Use the Network option in Control Panel to change the jumpers of your adapter card or to run the configuration utility that was supplied with the adapter. See your system administrator if you need assistance.
name : There is a memory conflict at address 0x address.
[Netevent]
Both the adapter and another device are using the address specified. Each device should have a unique address.
Contact your system administrator. Check the configuration of the adapter card by selecting Network in Control Panel. Make sure the adapter card is configured according to the manufacturer's specifications and that the card's configuration does not conflict with the configurations of other hardware.
name : There is a resource conflict at DMA channel number.
[Netevent]
The adapter and another device are trying to use the specified DMA channel.
Contact your system administrator. Check the configuration of the adapter card by selecting Network in Control Panel. Make sure the adapter card is configured according to the manufacturer's specifications and that the configuration does not conflict with the configurations of other hardware.
name : There is an I/O port conflict.
[Netevent]
The adapter card and another device are configured to use the same I/O port.
Contact your system administrator. Check the configuration of the adapter card by selecting Network in Control Panel. Make sure the adapter card is configured according to the manufacturer's specifications and that the configuration does not conflict with the configurations of other hardware.
name : There is an I/O port or DMA channel conflict.
[Netevent]
The adapter card and another device are configured to use the same I/O port or DMA channel.
Contact your system administrator. Check the configuration of the adapter card by selecting Network in Control Panel. Make sure the adapter card is configured according to the manufacturer's specifications and that the card's configuration does not conflict with the configurations of other hardware.
name : Timed out during an operation.
[Netevent]
The adapter card did not respond to a command.
No action is needed. However, if this occurs frequently, ask your system administrator to check the adapter settings and/or replace the adapter card.
name : Unknown host.
[FTP Server]
You specified a host name in the Ftp command that does not have an entry in the HOSTS file (which is located in \\systemroot\\system32\\drivers\\etc).
Either try again with a different host name, or create an entry for the host name in the HOSTS file. You might need to ask your network administrator to do this for you.
name :TLI Error number
[TCP/IP]
The TCP/IP utility named at the start of the message had a data connection fail due to an unexpected TLI error.
Retry the operation. If you get this message again, contact your network administrator to interpret the meaning of the TLI error code displayed at the end of the message and take corrective action.
name :TLOOK returned number text
[TCP/IP]
The TCP/IP utility named at the start of the message had a data connection fail due to an unexpected event.
Retry the operation. If you still get this message, contact your network administrator to interpret the meaning of the event number that is displayed at the end of the message and take corrective action.
name could not allocate a resource of type number due to a specifically configured limit of number.
[Netevent]
One of the Registry parameters, MaxLinks or MaxConnections, has been changed. The default for these parameters is unlimited.
Ask your system administrator to increase the MaxLinks or MaxConnections parameter in the Registry.
name could not allocate a resource of type number due to its configured size of number.
[Netevent]
Your server has reached the configured limit for NetBIOS.
Ask your system administrator to increase the configured size of the protocol if it is not already configured to its maximum limit. The protocol's size can be changed by choosing Server in Network in Control Panel.
name could not allocate a resource of type number due to system resource problems.
[Netevent]
The resource pool is not available because the server is busy.
Ask your system administrator to restart the server, or you can wait a few minutes and then try the operation again. If you see this message frequently, your system administrator may need to increase the server's memory.
name could not create a link to a remote computer. Your computer has exceeded the number of connections it can make to that remote computer.
[Netevent]
Your computer created too many connections to the network.
Wait a few minutes, then retry the operation.
name could not find adapter name.
[Netevent]
Ask your system administrator to verify that the NDIS driver loaded correctly.
name could not transfer a packet from the adapter. The packet was dropped.
[Netevent]
A hardware problem has occurred.
Check the event log in Event Viewer for related errors that may indicate the hardware problem. If the related errors are serious, you should contact technical support.
name discarded a read IOCTL ACK/NAK message of unknown type text.
[Netevent]
A lower layer of the protocol stack issued an invalid ACK/NAK message.
Contact technical support.
name discarded a read IOCTL message of unknown type text.
[Netevent]
A user-level application generated an invalid read IOCTL message. The application attempted to perform an operation that the protocol does not recognize.
Ask your system administrator to identify the application. The event log in Event Viewer may contain information about related errors which could help to identify the application so the problem can be corrected. Also, contact the vendor of the application.
name discarded a read message of unknown type text.
[Netevent]
An upper or lower layer of the protocol stack issued an invalid read message. This can occur during development of a streams-based transport.
Contact technical support.
name discarded a read PROTO message of unknown type text.
[Netevent]
An upper or lower layer of the protocol stack issued an invalid read PROTO message. This can occur during development of a streams-based transport.
Contact technical support.
name discarded a write IOCTL message of unknown type text.
[Netevent]
A user-level application generated an invalid write IOCTL message. The application attempted to perform an operation that the protocol does not recognize.
Ask your system administrator to identify the application. The event log in Event Viewer may contain information about related errors which could help to identify the application so the problem can be corrected. Also, contact the vendor of the application.
name discarded a write message of unknown type text.
[Netevent]
An upper or lower layer of the protocol stack issued an invalid write message. This can occur during development of a streams-based transport.
Contact technical support.
name discarded a write PROTO message of unknown type text.
[Netevent]
An upper or lower layer of the protocol stack issued an invalid write PROTO message. This can occur during development of a streams-based transport.
Contact technical support.
name failed to bind to adapter name.
[Netevent]
The specified adapter did not load, is out of memory, or is not configured properly.
Ask your system administrator to verify that the NDIS driver loaded correctly. Check the event log with Event Viewer for related errors.
name failed to register itself with the NDIS wrapper.
[Netevent]
The specified device is not the correct version for the NDIS wrapper.
Ask your system administrator to reinstall the correct version of the device from the Setup disks.
name failed while querying OID number on adapter name.
[Netevent]
There is either a hardware or driver problem with the NDIS driver.
Check the event log with Event Viewer for related errors.
name failed while setting OID number on adapter name.
[Netevent]
The NDIS driver has either a hardware or driver problem.
Check the event log with Event Viewer for related errors.
name has received number ICMP error packets on nonexistent connections.
[Netevent]
Multiple ICMP orphans have been received. This message gives the history of the error packets.
No action is needed.
name is already installed. Remove this font and re-install.
[Program Manager]
You must remove the old version of this font before you can install the new version.
name is already installed. Remove this font and re-install.
[Program Manager]
You must remove the old version of this font before you can install the new version.
name is an invalid user or group name.
[Network] Net Message ID: 3742
You typed an invalid user name or group name.
Check the spelling of the user or group name. To see a list of existing users, type NET USER. To see a list of existing local groups, type NET LOCALGROUP. To see a list of existing global groups, type NET GROUP, if you are running Windows NT Advanced Server. If you are running Windows NT, type NET GROUP /domain. The Windows NT workstation must be a member of a domain that is running Windows NT Advanced Server. Otherwise, you will see a message that tells you that NET GROUP is a Windows NT Advanced Server command only.
name is not a user account or group.
[User Manager]
The word you typed is not the name of a user account or group. It might have been mistyped.
Make sure you have the correct name. Then try again, making sure the name is typed correctly.
name is not a user account. Only users can be renamed.
[User Manager]
You cannot rename groups.
No action is needed. If you want, you can create a new group with the different name.
name is not a valid domain or workgroup name.
[Network] Net Message ID: 3932
The name you specified is not a valid domain or workgroup name.
Check the spelling of the name. Retype the command with a valid domain or workgroup name.
name is not a valid workstation name. You must either specify valid workstation names or leave the fields blank.
[User Manager]
The workstation name you entered does not follow the naming conventions for workstation names. The name can be up to 15 characters long and cannot include any of the following special characters: bullet (ALT+ 0149) currency sign (ALT+ 0164) broken vertical bar (ALT+ 0166) section sign (ALT+ 0167) paragraph sign (ALT+ 0182)
Try again, making sure to enter a valid workstation name. Or leave the fields blank.
name received an ICMP error packet of type text, code code.The packet that caused the error was sent from source address to destination address.
[Netevent]
Your local subnet received an invalid ICMP packet.
Ask your system administrator to correct the packets generated by the computer at the specified source IP address.
name received an unexpected text packet from a remote computer.
[Netevent]
Your network is experiencing hardware problems or the software versions on the two computers may conflict.
Contact technical support.
name text : name too long.
[TCP/IP]
This is an internal error in the Rpc utility.
Retry the operation. If you still get this message, contact your technical support group.
name was unable to extract the value of parameter name from the Registry. Setting to the default value of text.
[Netevent]
The device could not find the specified configurable parameter in the Registry so the default value was used.
No action is needed.
name was unexpected at this time.
[Command Prompt]
While processing a batch file, command prompt encountered an unexpected command.
Correct the batch file, then try running it again.
name was unexpected at this time.
[Command]
While processing a batch file, command prompt encountered an unexpected command.
Correct the batch file, then try running it again.
name: command/tcp: unknown service
[TCP/IP]
The service required to process the command named at the beginning of the message is not running on the remote host. The required service is named in the message.
Either run the command on a different server, or ask your network administrator to get the required service running on the remote host. You may need to contact the administrator of the remote host to do this.
number ARP requests received from other networks.
[Netevent]
Several invalid ARP requests were received from other networks and were discarded.
No action is needed.
number corrupt file was backed up.
[Backup]
One of the files that was backed up was corrupt.
No action is needed.
number corrupt files were backed up.
[Backup]
Some of the files that were backed up were corrupt.
No action is needed.
number directories were not found.
[Backup]
Some directories that were in the backup set's catalog were not found while verifying files.
No action is needed. If the verify was done after a backup, the directory may have been removed between the backup and verify operations. If the verify was done after a restore, the restore of the directory could have failed.
number directory was not found.
[Backup]
One directory that was in the backup set's catalog was not found while verifying files.
No action is needed. If the verify was done after a backup, the directory may have been removed between the backup and verify operations. If the verify was done after a restore, the restore of the directory could have failed.
number errors were logged in the last number minutes. Please review the server's error log.
[Network] Net Message ID: 3001
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The server and/or network hardware may need service.
Contact your network administrator.
number file was different.
[Backup]
One file was different in the target directory than on the backup tape. No differences were detected in the other files.
No action is needed.
number file was in use.
[Backup]
One file could not be backed up because it was in use.
No action is needed.
number file was skipped.
[Backup]
One file was not restored. It may have been open on the target disk, or the backup copy may have been corrupt.
No action is needed.
number files were different.
[Backup]
The specified number of files were different in the target directory than on the backup tape. No differences were detected in the other files.
No action is needed.
number files were in use.
[Backup]
Some files could not be backed up because they were in use.
No action is needed.
number files were not found.
[Backup]
The specified number of files were found on the backup tape but not in the target directory.
No action is needed. However you might want to restore the missed files in a separate operation. The missed files are listed in the summary box, and also in the log file for this operation.
number files were skipped.
[Backup]
The specified number of files were not restored. They may have been open on the target disk, or the backup copies may have been corrupt.
No action is needed.
number in-use file was restored.
[Backup]
One file was in use when the backup version of that file was restored. The backup version was restored anyway.
No action is needed.
number in-use files were restored.
[Backup]
Some files were in use when the backup version of those files were restored. The backup versions were restored anyway.
No action is needed.
number is not a recognized hour.
[Network] Net Message ID: 3762
You specified an hour in a format that could not be recognized. The hour can be a number from 0 to 12 in 12-hour format or 0 to 24 in 24-hour format. If you use the 12-hour format, you must specify either AM or PM for each time.
Retype the command with the correct hour format.
number is not a valid entry. Please specify a value between number and number for this field.
[Control Panel]
The value for this entry must be in the range specified; no other values can be used.
Enter a value in the specified range.
number is not a valid specification for minutes.
[Network] Net Message ID: 3763
You specified the minutes in a format that could not be recognized. Typing the minutes is optional, but if included, the format must be :00 (a colon and two zeros).
Retype the command, either omitting the minutes or using the correct format, :00.
number lost allocation units found in number chains.
[Chkdsk]
This is an informational message displayed by Chkdsk. These lost allocation units could be converted to files or to free space.
No action is needed.
number message allocations have failed since initialization.
[Netevent]
No action is needed unless you see this message frequently. Then add more memory.
number network errors occurred in the last number minutes. Please review the server's error log. The server and/or network hardware may need service.
[Network] Net Message ID: 3002
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer.
Contact your network administrator.
number security difference was found.
[Backup]
The data may have been in use when the backup was done or there may have been a problem with the backup or restore operation.
Use the Security menu in File Manager to view the security information on both versions of the data. If the information is not different, try backing up or restoring the data again.
number security differences were found.
[Backup]
The data may have been in use when the backup was done or there may have been a problem with the backup or restore operation.
Use the Security menu in File Manager to view the security information on both versions of the data. If the information is not different, try backing up or restoring the data again.
path Entry has a bad link
[Chkdsk]
The directory specified in the message has an entry with a bad link (the file allocation table chain has been broken).
Run the Chkdsk command with the /f switch to fix the problem.
path Entry has a bad size
[Chkdsk]
The directory specified in the message has an entry with a bad file size.
Run the Chkdsk command with the /f switch to fix the problem.
path has a remembered connection to drive letter.
[Network]
The indicated remote resource is usually assigned to the indicated driver letter or port name. It is not currently connected, but there would normally be an attempt to connect to it the next time you log on.
No action is needed.
path is an invalid path name. Please enter a valid path name.
[User Manager]
In the User Environment Profile dialog box, you specified a command path in the Home Directory or Profile Path option that does not exist in the location that you have specified.
Choose OK, then specify a valid Home Directory or Profile Path.
path is an invalid relative path name. Please enter a valid relative path name.
[User Manager]
In the User Environment Profile dialog box, you specified a command path in the Logon Script Name option that does not meet the criteria for a relative path.
Choose OK, then re-enter the pathname. Make sure to use a backslash (\) between the directory name and filename.
path is not a full path name.
[Utilities]
Enter a fully-qualified path (for example, d:\\winnt\\system32 is a fully-qualified path because it includes the drive letter and all sub directories leading to the target directory).
path Path does not exist. Please verify that the correct path is given.
[Common Dialog]
Check that the path is correct and complete. Then try again, making sure the path is typed correctly.
path Path does not exist. Please verify the correct path was given.
[Common Dialog]
You specified a path that does not exist. This could be a result of mistyping the path, or you might have the wrong name for the path, or some directories in this path might have been deleted.
Make sure that you have the correct path and that the path exists. Then try again, making sure you type the name correctly.
text First allocation unit is invalid, entry truncated
[Chkdsk]
The first allocation unit for the specified directory entry is invalid--since allocation in the FAT is chain-based, this means that the directory entry is useless.
No action is needed.
text : bad argument: text
The command cannot be carried out with this argument.
Try again, making sure to type the command correctly and use only the arguments that are valid for this command.
text : Cannot open filename
[FINDSTR]
The Findstr utility cannot open the file named in the message.
Check the Findstr command line and make sure that you specified the correct path and that there are no misspellings. You may need to use File Manager to search for the file. Also, check that you have access rights to the file.
text : No such device (CdRom number )!
[CD Player]
An error occurred when CD Player attempted to read configuration information from the Registry.
Quit and restart CD Player. Or, in the Registry, make sure that the SCSI ID's are correct.
text : not rerouted
[Utilities]
This is an informational message to notify you that LPTn: is not rerouted.
No action is needed.
text : unknown mode
[FTP Server]
The file transfer mode specified in an Ftp command is invalid or not supported. ASCII and binary/image are the supported modes.
Retry the Ftp command, specifying either ASCII or binary/image as the file transfer mode.
text Contains number non-contiguous blocks.
[Chkdsk]
This is an informational message.
No action is needed.
text FORMAT does not support user selected allocation unit sizes.
[Format]
The /a parameter was used when formatting a volume to a file system which does not support user selected allocation unit sizes. Only NTFS supports the /a parameter.
Do not use the /a parameter when formatting a volume to FAT or HPFS.
text is an invalid Trap Destination.
[TCP/IP]
Trap destinations are the names or IP addresses of hosts to which you want the SNMP service to send traps with the selected community name.
In the Host Name or IP Address text box, enter the name or IP address of a computer in the community you have selected. Then choose Add.
text is not a valid 12-hour suffix.
[Network] Net Message ID: 3766
You tried to use the 12-hour format, but the time was followed by text that was neither AM nor PM. If you use the 12-hour format, you must follow each time with either AM, A.M., PM, or P.M.
Retype the command with the correct forms of AM and PM.
user name has open files. Disconnecting user name may result in loss of data. Are you sure you want to disconnect this user from the Macintosh-Accessible volume name ?
[Services for Macintosh (SFM)]
Use Server Manager or File Manager to send a disconnect message to the specified user. In using either manager, select the MacFile menu. In Server Manager, select Send Message. In File Manager, select View/Modify Volumes and then select Send Message.
username has a Logon Hours setting which is not specified as days-per-week or hours-per-week. You may edit this setting, but it will be initially reset. Do you wish to reset and edit the Logon Hours setting for username?
[User Manager]
You changed a user's logon hours setting directly through the API.
If you wish to reset and edit the logon hours setting, choose OK.
username has a Logon Hours setting which is specified as days-per-week. Is it OK to convert username's setting to hours-per-week?
[User Manager]
You changed a user's logon hours setting directly through the API.
If you wish to convert the logon hours setting, choose OK.
' name ' is an invalid port name.
[Print Manager]
You attempted to configure a port, and specified the name of a file that does not exist or a network resource to which you are not currently connected. Or you typed a name that contains invalid characters.
Specify a valid port name.
',' expected
[Help]
This error is from the Macro Language Editor for on-line help, and should not appear while using the Help file. Report this error to the provider of the Help file.
(Error occurred in environment variable)
[Command]
The error displayed with this message occurred in the DIRCMD environment variable, rather than on the command line.
Use the Set command to view the current settings for the DIRCMD environment variable. Then type HELP DIR at the command prompt to see the correct syntax for the command.
(Setup is unable to access this disk.) name
[Setup]
The disk might not be accessible through the network. It might be off line. Setup cannot install Windows NT on the disk. This message is part of a larger message that contains more information about the error.
Install Windows NT on another disk.
*** NAME TOO LONG! ***
[PORTUAS]
Try again, using a shorter name.
**** Aborting ... Completing backup of file ****
[Backup]
The backup process will be stopped as soon as the application finishes backing up the file it is copying now.
No action is needed.
**** Aborting ... Completing restore of file ****
[Backup]
The restore process will be stopped as soon as the application finishes restoring the file it is copying now.
No action is needed.
**** Process Aborted ****
[Backup]
Either the process was canceled or it encountered an error that would not let it continue.
No action is needed. You can start restoring files again.
-- Error in conversion.
[Convert]
This access control entry could not be converted.
Apply permissions manually.
-- superfluous Access Control Entry dropped.
[Convert]
A LAN Manager access control entry which grants no permissions to a group has no effect, which is why the entry is superfluous. Such access control entries are dropped during conversion.
-- User or group ID not found.
[Convert]
This access control entry was not converted because the referenced user or group ID does not exist in this Windows NT system.
Create the appropriate user or group and manually apply the permissions.
Computer name is a member of domain name. Focus will be set to domain name.
[User Manager]
You are focusing User Manager on an Advanced Server that is not the domain controller.
No action is needed.
NetDDE Agent Not enough memory.
[Dynamic Data Exchange]
Close some applications and try again.
?Ambiguous command
[FTP Server]
During either a Telnet or Ftp session, you used a shortened version of a command that has more than one interpretation. For instance, at the ftp> prompt, you could type "qu," but that would be an ambiguous command because both "quit" and "quote" are valid commands in an Ftp session.
Retry the command, using a longer version, for example, spelling the command name all the way out. To see a list of all the valid commands in a Telnet or Ftp session, type "?" or "HELP" at the session command prompt.
?Ambiguous help command command
[FTP Server]
During either a Telnet or Ftp session, you used a shortened version of a command in a Help request, and that shortened version has more than one interpretation. For instance, at the ftp> prompt, you could type "help c," but that would be an ambiguous request for help because "connect," "close," and "crmod" are all valid commands in a Telnet session.
Change the form of the Help command to clear up the ambiguity, and retry the command.
?Invalid command
[FTP Server]
During either a Telnet or Ftp session, you used a command that is invalid in that session. For instance, "frammis" is not a valid command in either a Telnet or Ftp session.
During either a Telnet or Ftp session, you can display a list of valid commands by entering "?" or "HELP."
?Invalid help command command
[FTP Server]
During either a Telnet or Ftp session, you requested Help on a command for which there is no Help. The command you used in the help request is probably not a valid command in the session.
During either a Telnet or Ftp session, you requested Help on a command for which there is no Help. The command you used in the help request is probably not a valid command in the session.
[XOFF] (Press Ctrl-Break to reset.)
[Terminal]
The Xon/Xoff in the Communications dialog box dictates that a file transfer automatically pauses when the buffer is full. This setting is now activated, the buffer is full, and the file transfer in progress has paused.
No action is needed.
{Access Denied}A process has requested access to an object, but has not been granted those access rights.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, contact your system administrator to change your privilege level.
{Already Committed}The specified address range is already committed.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Application Error}The application failed to initialize properly (0xcode1x). Click on OK to terminate the application.
[Kernel]
This is a Windows NT Executive STATUS error message. After you terminate the application, try running it again. If this message reappears, contact the supplier of the application.
{Application Error}The exception code (0xcode8lx) occurred in the application at location 0xcode8lx.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box and then try running the application again. If this message reappears, contact the supplier of the application.
{Application Exit by CTRL+C}The application terminated as a result of a CTRL+C.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then restart the application if you need to.
{Bad CRC}A cyclic redundancy check (CRC) checksum error occurred.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box.
{Bad File}The attributes of the specified mapping file for a section of memory cannot be read.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Bad Image Checksum}The image name is possibly corrupt. The header checksum does not match the computed checksum.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then try running the application again. If this message reappears, contact the supplier of the executable file.
{Bad Image}The application or DLL name is not a valid Windows NT image. Please check this against your installation diskette.
[Kernel]
This is a Windows NT Executive STATUS error message. Correct the condition, as suggested in the message box, and restart the application (or .DLL). If this message reappears, contact your system administrator or the supplier of the executable file.
{Buffer Overflow}The data was too large to fit into the specified buffer.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. You may want to check the results from the running application.
{Buffer Too Small}The buffer is too small to contain the entry. No information has been written to the buffer.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Cancel Timeout}The driver name failed to complete a canceled I/O request in the allotted time.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box and retry the operation. If this message reappears, contact your system administrator, your technical support group, or the I/O device supplier.
{Conflicting Address Range}The specified address range conflicts with the address space.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Corrupt Disk}The file system structure on the disk is corrupt and unusable. Please run the Chkdsk utility on the volume name.
[Kernel]
This is a Windows NT Executive STATUS error message. Correct the condition, as suggested in the message box, and restart the application. If this message reappears, contact your system administrator or your technical support group.
{Corrupt File}The file or directory name is corrupt and unreadable. Please run the Chkdsk utility.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box and then run the Chkdsk utility.
{Data Error}An error in reading or writing data occurred.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. You may need to contact your technical support group.
{Data Late}A data late error occurred.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. You may need to contact your technical support group.
{Data Not Accepted}The TDI client could not handle the data received during an indication.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box and retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Data Overrun}A data overrun error occurred.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, run hardware diagnostics on your disk drives and controllers. You may have to contact the vendor of the device, and you may have to replace the controller, the disk drive, or both.
{Device Busy}The device is currently busy.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box (you may want to wait until the device may no longer be busy).
{Device Offline}The printer has been taken offline.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box (you may want to correct the situation first).
{Device Power Is Off}The printer power has been turned off.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box (you may want to correct the situation first).
{Device Timeout}The specified I/O operation on computer name was not completed before the time-out period expired.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box.
{DLL Initialization Failed}Initialization of the dynamic link library name failed. The process is terminating abnormally.
[Kernel]
This is a Windows NT Executive STATUS error message. Note the filename of the dynamic-link library and choose OK. Try reinstalling the .DLL from its distribution media and then retry the operation. If this message reappears, contact the supplier of the dynamic-link library.
{Drive Not Ready}The drive is not ready for use; its door may be open. Please check drive drive letter and make sure that a disk is inserted and that the drive door is closed.
[Kernel]
This is a Windows NT Executive STATUS error message. Check the drive and then choose one of the options from the message box.
{End of Media}The end of the media was encountered.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{Entry Point Not Found}The procedure entry point text could not be located in the dynamic link library name.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. You may have to reinstall the dynamic-link library or contact its supplier.
{EXCEPTION}A real-mode application issued a floating-point instruction and floating-point hardware is not present.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box.
{EXCEPTION}Alignment FaultA datatype misalignment was detected in a load or store instruction.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{EXCEPTION}Array bounds exceeded.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}BreakpointA breakpoint has been reached.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. If you are running the application in an end-user environment, rather than in a development environment, contact the supplier of the running application about this message. This should not happen when a finished program is running.
{EXCEPTION}Cannot Continue Windows NT cannot continue from this exception.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Floating-point denormal operand.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Floating-point division by zero.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Floating-point inexact result.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Floating-point invalid operation.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Floating-point overflow.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Floating-point stack check.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Floating-point underflow.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Guard Page ExceptionA page of memory that marks the end of a data structure, such as a stack or an array, has been accessed.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{EXCEPTION}Integer division by zero.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Integer overflow.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Possible deadlock condition.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Privileged instruction.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Then contact your technical support group.
{EXCEPTION}Single StepA single step or trace operation has just been completed.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. If you are running the application in an end-user environment, rather than in a development environment, contact the supplier of the running application about this message. This should not happen when a finished program is running.
{Fatal System Error}The name system process terminated unexpectedly with a status of 0xcode8x. The system has been shutdown.
[Kernel]
This is a Windows NT Executive STATUS error message. Write down any information you can about the shutdown event and restart your computer. If this message reappears, contact your system administrator or your technical support group.
{File Not Found}The file filename does not exist.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then use File Manager to search for the file. You may have to move the file, or install it, to avoid this message in the future.
{Filemark Found}A filemark was detected.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. No other action is needed.
{Floppy Disk Error}The floppy disk controller reported an error that is not recognized by the floppy disk driver.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Retry the operation, using a different floppy disk or a floppy disk with a different density. If this message reappears, contact the hardware supplier or the floppy disk driver software supplier.
{Floppy Disk Error}While accessing a floppy disk, an ID address mark was not found.
[Kernel]
This is a Windows NT Executive STATUS error message. Try running the application again. If this message reappears, contact the supplier of the application.
{Floppy Disk Error}While accessing a floppy disk, the track address from the sector ID field was found to be different than the track address maintained by the controller.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Retry the operation, using a different floppy disk or a floppy disk with a different density. If this message reappears, contact the hardware supplier or the floppy disk driver software supplier.
{Floppy Disk Error}While accessing a floppy-disk, the controller returned inconsistent results via its registers.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. This is either a hardware problem or a device driver problem. Check the hardware first. If this message reappears, contact the supplier of the floppy disk driver software and report your computer configuration.
{GUID Substitution}During the translation of an HPFS global identifier (GUID) to a Windows NT security ID (SID), no administratively-defined GUID prefix was found. A substitute prefix was used, which will not compromise system security. However, this may provide a more restrictive access than intended.
[Kernel]
This may provide a more restrictive access than intended, so this warning message is displayed.
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{Handles Closed}Handles to objects have been automatically closed as a result of the requested operation.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. You may want to check the results from the running application.
{Hard Disk Error}While accessing the hard disk, a disk controller reset was needed, but even that failed.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then contact the hard disk vendor and/or disk controller vendor.
{Hard Disk Error}While accessing the hard disk, a disk operation failed even after retries.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then run the Chkdsk utility, with the /r option, on the hard disk. After that, if this message reappears, run hardware diagnostics on the disk drive and its controller. If the diagnostics do not detect a problem, contact the hardware and/or driver software suppliers. Before you contact the suppliers, note the information about the event that is in the Event Log. Information in both the Description and Data areas of the Event Detail window will be relevant to this problem.
{Hard Disk Error}While accessing the hard disk, a recalibrate operation failed, even after retries.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Run the Chkdsk utility, with the /r option, on the hard disk. After that, if this message reappears, run hardware diagnostics on the disk drive and its controller. If the diagnostics do not detect a problem, contact the hardware and/or driver software suppliers. Before you contact the suppliers, note the information about the event that is in the Event Log. Information in both the Description and Data areas of the Event Detail window will be relevant to this problem.
{Illegal EA}The specified extended attribute (EA) name contains at least one illegal character.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{Image Relocated}An image file could not be mapped at the address specified in the image file. Local fixups must be performed on this image.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue.
{Inconsistent EA List}The extended attribute (EA) list is inconsistent.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{Incorrect Network Resource Type}The specified device type (LPT, for example) conflicts with the actual device type on the remote resource.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then contact your network administrator.
{Incorrect Password to LAN Manager Server}You specified an incorrect password to a LAN Manager 2.x or MS-NET server.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then try a different password.
{Incorrect System Call Level}An invalid level was passed into the specified system call.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box and retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Incorrect Volume}The target file of a rename request is located on a different device than the source of the rename request.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. If you can, rename the file by copying it, or specify the same drive for both the original and changed file names.
{Insufficient Resources on Remote Computer}The remote computer has insufficient resources to complete the network request. For instance, there may not be enough memory available on the remote computer to carry out the request at this time.
[Kernel]
Wait a few seconds, then retry the operation. If this message reappears, ask your network administrator to check the remote computer.
{Invalid Current Directory}The process cannot switch to the startup current directory name. Select OK to set current directory to name, or select CANCEL to exit.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose an option from the message box.
{Invalid EA Flag}An invalid extended attribute (EA) flag was set.
[Kernel]
There is a problem with disk I/O.
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{Invalid Lock Sequence}An attempt was made to execute an invalid lock sequence.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Invalid Mapping}An attempt was made to create a view for a section which is bigger than the section.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. If you can, retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Invalid Parameter}The specified information class is not a valid information class for the specified object.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. Retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Kernel Debugger Awakened}the system debugger was awakened by an interrupt.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box.
{Local Session Key}A user session key was requested for a local RPC connection. The session key returned is a constant value and not unique to this connection.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Lost Delayed-Write Data}The system was attempting to transfer file data from buffers to filename. The write operation failed, and only some of the data may have been written to the file.
[Kernel]
There may have been a loss of data. Decide if the missing data is important enough to restore the file from backup and redo the file operations that led up to the message.
{Mapped View Alignment Incorrect}An attempt was made to map a view of a file, but either the specified base address or the offset into the file were not aligned on the proper allocation granularity.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box and retry the operation. If this message reappears, contact your system administrator or your technical support group.
{Missing System File}The required system file filename is bad or missing.
[Kernel]
This is a Windows NT Executive STATUS error message. Note the filename in the message and choose one of the options from the message box. Then reinstall the Windows NT system file named in the message.
{Network Name Not Found}The specified share name cannot be found on the remote server.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. You might want to contact your network administrator.
{Network Request Timeout}The session with a remote server has been disconnected because the time-out interval for a request has expired.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. You may want to try to reestablish the connection with the server.
{No Disk}There is no disk in the drive. Please insert a disk into drive drive letter.
[Kernel]
This is a Windows NT Executive STATUS error message. You may want to insert a disk in the drive. Then choose the appropriate option from the message box.
{No Media}There is no media in the drive. Please insert media into drive drive letter.
[Kernel]
This is a Windows NT Executive STATUS error message. You may want to insert media into the drive named in the message. Then choose the appropriate option from the message box.
{No More EAs}No more extended attributes (EAs) were found for the file.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. No other action is needed.
{No More Entries}No more entries are available from an enumeration operation.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. No other action is needed.
{No More Files}No more files were found which match the file specification.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. No other action is needed.
{No Paging File Specified}No paging file was specified in the system configuration.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then contact your system administrator to change the system configuration.
{No Quotas}No system quota limits are specifically set for this account.
[Kernel]
This Windows NT Executive STATUS message is supplemental information about a successful logon. Choose OK to continue. No other action is needed.
{Non-Inheritable ACL}An access control list (ACL) contains no components that can be inherited.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. No other action is needed.
{Not Enough Quota}Not enough virtual memory or paging file quota is available to complete the specified operation.
[Kernel]
This is a Windows NT Executive STATUS error message. Try running the application again. If this message reappears, contact your system administrator to adjust your paging file size or your quota.
{Not Implemented}The requested operation is not implemented.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. If you retry the operation and this message reappears, contact your system administrator or your technical support group.
{Object Exists}An attempt was made to create an object and the object name already existed.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Operation Failed}The requested operation was unsuccessful.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. If you choose Retry and this message reappears, contact your system administrator or your technical support group.
{Ordinal Not Found}The ordinal text could not be located in the dynamic link library name.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. You may have to reinstall the dynamic-link library or contact its supplier.
{Out of Paper}The printer is out of paper.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box (you may want to correct the situation first).
{Out of Virtual Memory}Your system is running low on virtual memory. Please close some applications. You can then start the System option in the Control Panel and choose the Virtual Memory button to create an additional paging file or to increase the size of your current paging file.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box and then close some unneeded applications. Later, you may want to create another paging file or increase the size of your current paging file.
{Page Locked}One of the pages to lock was already locked.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. No other action is needed.
{Page Unlocked}The page protection of a locked page was changed to 'No Access' and the page was unlocked from memory and from the process.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. No other action is needed.
{Partial Copy}Due to protection conflicts not all the requested bytes could be copied.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. You may want to check the results from the running application.
{Password Too Complex}The NT password is too complex to be converted to a LAN Manager password. The LAN Manager password returned is a NULL string.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Path Not Found}The path path does not exist.
[Kernel]
This is a Windows NT Executive STATUS error message. Check the path displayed in the message. You may have to create a directory or, if you enter a path through the application user interface, specify a different path. Try running the application again. If this message reappears, contact your system administrator or your technical support group.
{Privilege Failed}The I/O permissions for the process could not be changed.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then contact your system administrator about changing privilege levels.
{Redundant Read}To satisfy a read request, the NT fault-tolerant file system successfully read the requested data from a redundant copy. This was done because the file system encountered a failure on a member of the fault-tolerant volume, but was unable to reassign the failing area of the device.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Redundant Write}To satisfy a write request, the NT fault-tolerant file system successfully wrote a redundant copy of the information. This was done because the file system encountered a failure on a member of the fault-tolerant volume, but was not able to reassign the failing area of the device.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Registry File Failure}The registry cannot load the hive (file):filename or its log or alternate. It is corrupt, absent, or not writeable.
[Kernel]
This is a Windows NT Executive STATUS error message. Contact your system administrator right away about this computer configuration (Registry) problem.
{Registry Recovery}One of the files containing the system's Registry data had to be recovered by use of a log or alternate copy. The recovery was successful.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Reply Message Mismatch}An attempt was made to reply to an LPC message, but the thread specified by the client Id in the message was not waiting on that message.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. If you retry the operation and this message reappears, contact your system administrator or your technical support group.
{Section Too Large}The specified section is too big to map the file.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. If you choose Retry and this message reappears, contact your technical support group.
{Sector Not Found}The specified sector does not exist.
[Kernel]
There is a problem with disk I/O.
This is a Windows NT Executive STATUS error message. Choose an option from the message box. If you choose Retry and this message reappears, contact your system administrator, your technical support group, or your hardware supplier.
{Segment Load}A virtual DOS machine (VDM) is loading, unloading, or moving an MS-DOS or Win16 program segment image. An exception is raised so a debugger can load, unload or track symbols and breakpoints within these 16-bit segments.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue.
{Serial IOCTL Complete}A serial I/O operation was completed by another write to a serial port.(The IOCTL_SERIAL_XOFF_COUNTER reached zero.)
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Serial IOCTL Timeout}A serial I/O operation completed because the time-out period expired.(The IOCTL_SERIAL_XOFF_COUNTER had not reached zero.)
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Still Busy}The specified I/O request packet (IRP) cannot be disposed of because the I/O operation is not complete.
[Kernel]
This is a Windows NT Executive STATUS error message. If you have a chance to continue the application, wait a while and then continue. Otherwise, try running the application again. If this message reappears, contact your system administrator.
{The Registry Is Corrupt}The structure of one of the files that contains Registry data is corrupt, or the image of the file in memory is corrupt, or the file could not be recovered because the alternate copy or log was absent or corrupt.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then contact your system administrator right away about this computer configuration Registry problem.
{Thread Suspended}A thread termination occurred while the thread was suspended. The thread was resumed, and termination proceeded.
[Kernel]
This Windows NT executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Too Much Information}The specified access control list (ACL) contained more information than was expected.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. You may need to contact your system administrator to look at, and possibly edit, the access control list.
{Unable to Create Paging File}The creation of the paging file filename failed (codex). The requested size was number.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box. Then try creating a smaller paging file, or use a different disk partition for the paging file.
{Unable To Locate DLL}The dynamic link library name could not be found in the specified path path.
[Kernel]
This is a Windows NT Executive STATUS error message. Note the filename and path listed in the message box and then choose an option. Use File Manager to locate a path to the DLL on your computer. You will either have to change the path, move the dynamic-link library, or install the dynamic-link library.
{Unable to Retrieve Browser Server List}The list of servers for this workgroup is not currently available.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose one of the options from the message box and retry the operation. If this message reappears, contact your system administrator.
{Unexpected Failure in DebugActiveProcess}An unexpected failure occurred while processing a DebugActiveProcess APIrequest. You may choose OK to terminate the process, or Cancel to ignore the error.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box.
{Unknown Disk Format}The disk in drive drive letter is not formatted properly. Please check the disk, and reformat if necessary.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box and check the disk as suggested in the message. After that, if this message reappears, contact your disk hardware vendor.
{Verifying Disk}The media has changed and a verify operation is in progress so no reads or writes may be performed to the device, except those used in the verify operation.
[Kernel]
This Windows NT Executive STATUS message is a warning. Choose one of the options from the message box. Wait and retry the operation.
{Virtual Circuit Closed}An existing connection (virtual circuit) has been broken at the remote computer. There is probably something wrong with the network software protocol or the network hardware on the remote computer.
[Kernel]
Try the operation again. If this message reappears, ask your network administrator to check the network adapter and wiring connections on the remote computer. Also, the remote computer may have the wrong version of the network protocol installed.
{Virtual Circuit Closed}The network transport on a remote computer has closed a network connection. There may or may not be I/O requests outstanding.
[Kernel]
If you expected this message, no other action is needed. If the message is unexpected, you may want to check the results of the application that was disconnected. If this message often occurs unexpectedly, contact your network administrator.
{Virtual Circuit Closed}The network transport on your computer has closed a network connection because it had to wait too long for a response from the remote computer.
[Kernel]
Try the operation again. If this message reappears, ask your network administrator to check the status of the remote computer.
{Virtual Circuit Closed}The network transport on your computer has closed a network connection. There may or may not be I/O requests outstanding.
[Kernel]
If you expected this message, no other action is needed. If the message is unexpected, you may want to check the results of the application that was disconnected. If this message often occurs unexpectedly, contact your network administrator.
{Working Set Range Error}An attempt was made to set the working set minimum or maximum to values which are outside of the allowable range.
[Kernel]
This Windows NT Executive STATUS message is for your information. Choose OK to continue. No other action is needed.
{Write Protect Error}The disk cannot be written to because it is write protected. Please remove the write protection from the volume name in drive drive letter.
[Kernel]
This is a Windows NT Executive STATUS error message. Correct the condition and either continue running the application or restart the application. If this message reappears, contact the supplier of the application.
{Wrong Type}There is a mismatch between the type of object required by the requested operation and the type of object that is specified in the request.
[Kernel]
This is a Windows NT Executive STATUS error message. Choose an option from the message box. If you Retry and this message reappears, contact your system administrator or your technical support group.
0.0.0.0 is an invalid Default Gateway address.
[TCP/IP]
At least one of the numbers in the Default Gateway address must be non-zero. This is the IP address of the default gateway used to forward packets to other networks or subnets. If this parameter is not provided, IP functionality will be limited to the local subnet unless a route is specified with the ROUTE command.
Ask your network administrator for the correct Default Gateway address.
10 Mismatches - ending compare
[File Compare]
The Comp command has found enough differences between the two files it is comparing to conclude that the files are indeed different. Doing any more compares would be a waste of time.
12 and 24 hour time formats may not be mixed.
[Network] Net Message ID: 3765
You mixed 12- and 24-hour formats in your time specification. If you use the 12-hour format (with AM and PM), the hours must be from 0 to 12. If you use 24-hour format, the hours must be from 0 to 24.
Retype the command with either the 12- or 24-hour format.
A adapter name specified was greater than the maximum length allowed for adapter "name ".
[Services for Macintosh (SFM)]
Adapter names are limited to 32 characters.
In the Registry, change the value of key, HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\AppleTalk\Adapters\<adapter name>\PortName, to be less than 32 characters.
A bad mailslot server message block (SMB) was received. The SMB is the data.
[Network] Net Message ID: 3165
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. A software error occurred.
Contact technical support.
A bad value is in the units-per-week field of the user record.
[Network] Net Message ID: 3720
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The internal record of this user is invalid.
Contact technical support.
A call to a system service failed unexpectedly. The data is the error.
[FTP Server]
A critical system call failed so the FTP service could not be initialized. The service could not register with the service controller.
Contact technical support.
A centralized logon-server conflict occurred.
[Network] Net Message ID: 2210
You can't start the Netlogon service on this server because a server in the domain with an earlier version of the software is running the Netlogon service.
Before you can start the Netlogon service on this server, you must stop the Netlogon service on all servers in the domain running earlier versions of the software.
A child window failed to initialize! App will exit.
[CD Player]
Either you are low on system resources, or an internal software error has occurred.
No action is needed.
A command or response in the device .INF file section refers to an undefined macro.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and then reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
A command was used with conflicting switches.
[Network] Net Message ID: 3510
You typed a command with two options that conflict, such as /YES and /NO.
Retype the command without contradictory options.
A comment must be provided for the scope.
[DHCP]
Enter a descriptive comment in the Comment text box.
A conflict has been detected between two drivers which claimed equivalent IRQs. Driver name, with device name, claimed an interrupt with Level in data address0x28, vector in data address 0x2c and Affinity in data address 0x30.
Two drivers are requesting exclusive use of the same interrupt (IRQ). The second driver cannot be loaded, and functionality dependent on this driver will not be available.
Change the IRQ value for the specified driver. Or, if you know which driver is competing for this IRQ, change the IRQ value for that driver.
A conflict has been detected between two drivers which claimed two overlapping IO port regions. Driver name, with device name, claimed an IO port range with starting address in data address 0x28 and 0x2c, and length in data address 0x30.
Two drivers are requesting exclusive use of the same I/O ports. The second driver cannot be loaded, and functionality dependent on this driver will not be available
Change the set of I/O ports for the specified driver. Or, if you know which driver is competing for this range of I/O ports, change them for that driver.
A connection could not be established to the specified computer.
[Clipboard]
You attempted unsuccessfully to connect to a remote computer. The computer may not be started.
Wait and try again.
A continuous RESET state has been entered.
[Virtual DOS Machine (VDM)]
The virtual DOS keyboard is in a continuous reset state and is unusable.
Terminate the application, then restart it. If you still get this message, contact your technical support group or the supplier of the application.
A corrupt extension "path " was detected in the registry. This value was ignored.
[Services for Macintosh (SFM)]
The corrupt extension may not have any characters or it may have more than three characters.
Use the Registry editor to correct the corrupt extension. Delete the invalid extension in the \\HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\MacFile\Parameters\Extensions Registry key.
A corrupt type/creator pair with type "text" and creator "text" was detected in the registry. This value was ignored.
[Services for Macintosh (SFM)]
Use the Registry Editor to change the corrupt value in the Registry. The value is located in the \\HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\MacFile\Parameters\Type_Creators key.
A cross-encrypted password is necessary to change this user password.
[Kernel32]
Contact the supplier of the running application.
A defective sector on drive drive letter has been replaced (hotfixed). No data was lost. You should run CHKDSK soon to restore full performance and replenish the volume's spare sector pool. The hotfix occurred while processing a remote request.
[Network] Net Message ID: 3181
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The fault-tolerant system found a bad disk sector and rerouted data to a good sector (this is called hotfixing).
Run CHKDSK soon to ensure that enough good disk sectors are available for hotfixing.
A device attached to the system is not functioning.
[Kernel32]
An attached device is not working for one of these reasons: (1) it is switched off, or connected improperly; (2) the floppy disk and drive types are incompatible; (3) the floppy disk is not properly inserted in the drive; (4) the drive door is open; or (5) the floppy disk is not properly formatted.
Correct the problem and retry the command.
A different disk is expected in drive drive letter :.Please insert the appropriate disk.
[Common Dialog]
Remove the disk that is in the indicated drive, and insert the disk required by the program.
A directory change notification was missed on volume "name ".
[Services for Macintosh (SFM)]
A change was made to a directory but the Services for Macintosh File Server could not be notified of the change. The change may have been that a file was created or deleted or renamed. The size or date on a file might have changed also. The view of the disk seen by a Macintosh client may not be consistent with the actual state of the disk. The notification could have been missed because the server may be running out of memory.
Use the Services option in Control Panel to stop and restart the File Server for Macintosh service.
A disk fault tolerance set member listed in the configuration information was missing.
[Disk Administrator]
This can only happen at system startup. Check the cables to your disk drives. Then restart your computer. If you still get this message, contact technical support or your disk vendor to run hardware diagnostics on your disk drives.
A disk I/O failure occurred.
[Network] Net Message ID: 2229
A software error occurred while Windows NT tried to access the down-level security database file.
Type the command again. If the error persists, use a backup copy of the security database from a server and try the command again. If the error persists, your disk drive may have hardware problems.
A domain controller for your domain could not be contacted. You have been logged on using cached account information. Changes made to your profile since you last logged on may not be available.
[Workstation-Logon]
Possibly, your domain controller is temporarily malfunctioning. When you log on to a domain, the logon information is saved, but changes made to your profile may not be.
You can still log on, but you may wish to wait until the domain controller can be contacted.
A DosDevIoctl or DosFsCtl to NETWKSTA.SYS failed. The data shown is in this format:DWORD approx CS:IP of call to ioctl or fsctlWORD error codeWORD ioctl or fsctl number
[Network] Net Message ID: 3108
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. A software error occurred.
Contact technical support.
A drive error was detected.
[Backup]
The tape drive did not initialize properly.
Messages that preceded this one provided more information about the error.
A driver packet received from the I/O subsystem was invalid. The data is the packet.
[Netevent]
The driver is functioning properly but is logging incorrectly formatted packets in the event log.
Examine the data in the event log in Event Viewer for the Unicode version of the driver's name and replace the packets or contact the supplier of the driver.
A duplicate file name exists, or the file cannot be found.
[Command]
Command Prompt cannot find the file that you want to rename, or there is another file in the directory using the new name.
Make sure you typed the correct filename and path. If a file with that name already exists, rename it, delete it, or specify a different filename for the file that you want to rename.
A duplicate file name exists, or the file cannot be found.
[Command Prompt]
Command Prompt cannot find the file that you want to rename, or there is another file in the directory using the new name.
Make sure you typed the correct filename and path. If a file with that name already exists, rename it, delete it, or specify a different filename for the file that you want to rename.
A duplicate message alias exists on the network.
[Network] Net Message ID: 2297
The name you specified is already in use as a message alias on the network.
Use a different name.
A duplicate name exists on the network.
[Kernel32]
Another computer or user on the network is already using this name. Your computer name must be unique on the network.
Choose another name for your computer, then retry the command.
A dynamic link library (DLL) initialization routine failed.
[Kernel32]
Contact the supplier of the dynamic-link library (DLL).
A failure occurred when executing a remote administration command.
[Network] Net Message ID: 2315
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The command cannot run on the remote server, probably because of a problem with the server's operating system configuration.
Have your network administrator check the configuration of the server's operating system.
A failure occurred when opening a remote temporary file.
[Network] Net Message ID: 2316
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The command could not be completed because it could not open a temporary file on the server.
See your network administrator. If you need further help, contact technical support.
A fatal error occurred while initialize a helper thread.
[Services for Macintosh (SFM)]
Restart your computer. If you see this message again, contact technical support.
A fatal internal error was detected in the AppleTalk stack.
[Services for Macintosh (SFM)]
Contact technical support.
A file contains extended attributes, but the extended attribute file was not found.
[Convert]
During a FAT to NTFS file conversion, the Convert utility could not find the extended attribute file associated with a FAT file.
The FAT volume is corrupted. Run the Chkdsk utility with the /f option and then retry the conversion.
A file or directory by this name already exists. Within a directory, file and directory names must be unique.
[File Manager]
Using the Rename option, you attempted to assign a file a name that already exists in the current directory.
Follow the user action specified in the message.
A file system error occurred while opening or writing to the system message log file filename. Message logging has been switched off due to the error. The error code is the data.
[Network] Net Message ID: 3150
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. An error occurred when the Messenger service tried to access the message log, so message logging has stopped. The error may have been caused by a full disk, a disk error, the file being locked by another process, or any other situation that would cause an error while writing to a file.
If the disk is full, free space on it by deleting unnecessary files and directories. Then check that the message log file is accessible, and start message logging by typing NET LOG /ON.
A floating-point operation at the RPC server caused a division by zero.
[Kernel32]
In a distributed (RPC) application, a server attempted a floating-point divide by zero operation.
Contact the supplier of the running application.
A floating-point overflow occurred at the RPC server.
[Kernel32]
In a distributed (RPC) application, a floating-point overflow occurred at the server.
Contact the supplier of the running application.
A floating-point underflow occurred at the RPC server.
[Kernel32]
In a distributed (RPC) application, a floating-point underflow occurred at the server.
Contact the supplier of the running application.
A general error occurred while trying to decompress the file filename.
[Setup]
The Windows NT Setup program cannot copy a distribution file for some non-specific reason.
Select the Retry option. If you still get this message, select Exit Setup and retry the Setup operation from the beginning. You may have to get another copy of the distribution medium.
A general error occurred while trying to decompress the file filename.
[Repair Disk]
The Windows NT Setup program cannot copy a distribution file for some non-specific reason.
Select the Retry option. If you still get this message, select Exit Setup and retry the Setup operation from the beginning. You may have to get another copy of the distribution medium.
A general network error occurred.
[Network] Net Message ID: 2136
A general failure occurred in the network hardware. This problem may be due to a hardware conflict and could have been generated by any number of other Server service commands (for example, Replicator).
See your network administrator. The problem could have occurred because of the hardware or software installed on your computer.
A key could not be created/opened
[WINS Service]
The WINS configuration is stored in the Registry, under Current Control Set\Software\WINS key. One of the keys in this section could not be created (or opened).
Ask the administrator to check that the entry is correct, or reinstall WINS.
A line in the configuration file is too long.
[Network] Net Message ID: 2149
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer.
Edit the configuration file.
A list variable in the .INF file filename is not terminated.
[Setup]
Setup loaded an .INF file and began interpreting it. It could not be interpreted.
Select Retry to retry the operation. If you get the same message, select Exit Setup. Then restore the .INF file from the distribution medium (you will have to decompress the file). Retry the Setup operation from the beginning. If you get this same message, contact your technical support group.
A list variable in the .INF file filename is not terminated.
[Repair Disk]
Setup loaded an .INF file and began interpreting it. It could not be interpreted.
Select Retry to retry the operation. If you get the same message, select Exit Setup. Then restore the .INF file from the distribution medium (you will have to decompress the file). Retry the Setup operation from the beginning. If you get this same message, contact your technical support group.
A lock request was not outstanding for the supplied cancel region.
[Kernel32]
Contact the supplier of the running application.
A logon request contained an invalid logon type value.
[Kernel32]
Three logon types are recognized by Windows NT: interactive, network, and service.
Contact the supplier of the running application.
A machine account for user name already exists.
[Server Manager]
You cannot create an account for this computer name because there is already one on the domain. You cannot add a new computer with this name unless the old computer name is removed from the domain.
Make sure you typed the computer name correctly. If this is the computer name you wanted to add, no action is needed.
A Macintosh workstation submitted a job with Adobe Document Structuring Convention comments that could not be processed. The job from computer name was canceled.
[Services for Macintosh (SFM)]
Switch to a driver that uses a more recent version. Adobe LaserWriter GX is not supported.
A macro required by the device was not found in the device .INF file section.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
A matching share could not be found so nothing was deleted.
[Network] Net Message ID: 3719
Windows NT could not find the resource you wanted to stop sharing.
Check the spelling of the share name. To see a list of the resources the server is sharing, type NET SHARE.
A message was received on an association. The association is in a bad state. This indicates a bug in WINS code.
[WINS Service]
Contact Microsoft Product Support.
A MIDI map was not found. There may be a problem with the driver, or the MIDIMAP.CFG file may be corrupt or missing.
Restore your MIDIMAP.CFG file from a backup copy, and try again.
A name release request was received for a record number that didn't have the same address as the requester. The request has been ignored.
[WINS Service]
A multihomed client released a name that had not yet been marked as multihomed in the WINS database. This can happen when only one registration for a name has reached the WINS server; the other names might have gone to another WINS server and not been replicated yet.
No action is needed.
A name release request was received for a record that didn't match the unique/group type indicated in the request. The request has been ignored.
[WINS Service]
One computer registered a name (unique or group) and then powered off. A second computer then registered the same name as a the other type (unique or group), and then released it. This second registration went to a backup WINS server, but the release went to the primary WINS server. The primary had not yet received the replica from the backup, and so the type specified in the release is not the same as the type specified in the registration it has.
No action is needed.
A NetBIOS error has occurred.
[Remote Access Service]
Your modem may not have negotiated the connection correctly, or the line may be noisy.
Set the modem to a lower initial speed (bps), and dial again. For more information see "Setting Modem Features" and "Modem Idiosyncrasies" in the Remote Access Service online Help. Please record the Fail Code (a NetBIOS error code), and make it available to your technical support staff if you call for help.
A NetWksta internal error has occurred: code
[Network] Net Message ID: 3190
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. A software error occurred.
Contact technical support.
A network adapter at the server failed.
[Remote Access Service]
Contact your system administrator and report this error.
A network adapter hardware error occurred.
[Kernel32]
The hardware that connects your computer to the local area network is experiencing a problem.
Make sure the cable on the back of your computer is properly connected, then retry the command. If you continue to have problems, contact your network administrator or the manufacturer of the network hardware.
A network resource shortage occurred.
[Network] Net Message ID: 2105
The network hardware could not access the resources it needed. This may have occurred because too many sessions are operating or the server is out of memory.
Try the command again later.
A new member could not be added to a local group because the member does not exist.
[Kernel32]
Contact the supplier of the running application.
A new member could not be added to a local group because the member has the wrong account type.
[Kernel32]
Contact the supplier of the running application.
A newer version of Help is needed to read this Help file.
[Help]
You tried to view a Help file that was written for a more recent version of the Help engine than is installed on your computer.
Install the latest version of Windows NT.
A non-existent section was referenced in a Setup Script command in section:
[Setup]
Setup was unable to interpret the .INF file. It is probably corrupted.
Select OK to exit Setup. Then restore the .INF file from the distribution medium (you will have to decompress the file). Retry the Setup operation. If you get this same message, contact your technical support group.
A non-existent section was referenced in a Setup Script command in section:
[Repair Disk]
Setup was unable to interpret the .INF file. It is probably corrupted.
Select OK to exit Setup. Then restore the .INF file from the distribution medium (you will have to decompress the file). Retry the Setup operation. If you get this same message, contact your technical support group.
A non-recoverable error occurred. The process ended.
[Command Prompt]
A system error has ended the current process, and the specific nature of the error cannot be determined.
If possible, reinitiate the process.
A non-recoverable error occurred. The process ended.
[Command]
A system error has ended the current process, and the specific nature of the error cannot be determined.
If possible, reinitiate the process.
A null context handle was passed from the client to the host during a remote procedure call.
[Kernel32]
Contact the supplier of the running distributed application.
A null reference pointer was passed to the stub.
[Kernel32]
This happened during a remote procedure call (RPC).
Contact the supplier of the running distributed application.
A parity error was detected on name.
Check the hardware cabling for the named device. After that, if this message reappears, contact the vendor of the named device.
A password mismatch has been detected.
[Network] Net Message ID: 2458
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. You have recently changed your password and the server does not recognize it.
Log off from the network, and then log on again. This changes the user accounts database and allows the server to recognize the password.
A person answered instead of a modem.
[Remote Access Service]
A modem did not pick up the phone.
Please check the number and dial again.
A power failure has occurred at computer name. Please terminate all activity with this server.
[Network]
The server is about to shut down due to a power failure. Any files that you have open on the server when it shuts down could be corrupted.
Immediately close all files and applications that are on or are using this server.
A power failure was detected at name. The server has been paused.
[Network]
No connections can be made to the server while it is paused.
Because servers are usually paused before they are shut down, you should close any files or applications that you have open on this server.
A power failure was detected at the server.
[Network] Net Message ID: 3230
The server had a power failure.
The UPS service is shutting down the server. Stop applications that are running on the server and have users disconnect from the server.
A primary domain controller is already running in this domain.
[Network]
The Primary Domain Controller (PDC) was temporarily removed from the network and a Backup Domain Controller (BDC) was promoted. This error appears when the original PDC is reconnected.
Demote one of the PDCs, using Server Manager.
A problem exists with the Emergency Repair Information File on the disk you have provided or the Windows NT installation you specified: text Setup cannot repair the file. \a To skip this file, press ENTER. The file will not be repaired. To exit Setup, press F3.
[Setup]
Let Setup search your hard disk for a Windows NT installation to repair.
A problem exists with the Emergency Repair Information File on the disk you have provided or the Windows NT installation you specified: filename Setup cannot use the file to repair the selected Windows NT installation. \a To provide a different Emergency Repair Disk or to specify a different Windows NT installation, press ENTER. To exit Setup, press F3.
[Setup]
Let Setup search your hard disk for a Windows NT installation to repair.
A problem exists with the system configuration.
[Network] Net Message ID: 3055
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The system is not configured correctly.
Contact your network administrator.
A Problem occurred while initializing CD Player. App will be terminated.
[CD Player]
Either you are low on system resources, or an internal software error has occurred.
If you have a number of applications running, close some of them, and then try again to initialize CD Player. If this message reappears, shut down and restart Windows NT.
A read-only file cannot be changed and saved. If you want to save this version of the file, use the Save As command to save the file to a different file name or use the Properties command in File Manager to change the file attributes.
[Paintbrush]
You attempted to save changes to a read-only file.
If the file belongs to you, follow the action specified in the message. If the file does not belong to you, you should copy it and save it under a different name.
A record could not be registered because it already existed. However, the same record then could not be found. The database might be corrupt.
[WINS Service]
Stop and restart the WINS service. If this error occurs often, call Microsoft Product Support.
A remote API error occurred.
[Network] Net Message ID: 2127
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The program or command you were running on a server could not be completed. There may be communication problems on the network, or the remote server may be short of resources.
Contact your network administrator. Your administrator should make sure that the server is configured with enough resources. Specifically, the NUMBIGBUF entry in the server's configuration file may need to be increased. Tell your network administrator that a remote API error occurred.
A remote API request was halted due to the following invalid description string: text.
[Network] Net Message ID: 3125
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The server received an invalid request to run a command. The request may have been damaged by the network.
No action is needed. If this error occurs frequently, contact technical support. Tell technical support that a remote API request was halted due to an invalid description string.
A remote procedure call (RPC) protocol error occurred.
[Kernel32]
The server and workstation configurations may be incompatible.
Contact your network administrator to check the compatibility of your workstation and the server on the network. If they are compatible, and this message reappears, you will have to contact the supplier of the running distributed application.
A replica clashed with a static record in the database. The replica was rejected.
[WINS Service]
An address has been dynamically assigned by one computer that was already statically assigned by another computer.
Check the WINS databases of other WINS servers and eliminate duplication of this address. Check the static record; you might choose to delete it.
A request for resource could not be satisfied.
[Network] Net Message ID: 3054
The service required more of the listed resource than was available.
Increase the amount of this resource. Stopping other services or applications may free some resources, such as memory. Also, check the disk where your pagefile(s) are located. If this disk is full, delete unnecessary files and directories from it to clear space.
A request has been submitted to promote the computer to backup when it is already a master browser.
[Netevent]
The computer is already at the highest level that it can reach. In the browser, computers are either client, potential, backup, or master, with client computers having the least power and master browsers having the most power. When a browser comes online, it announces itself to the master browser. The master browser asks a fraction of these browsers to become backup browsers. The master browser itself has received one of these requests.
Contact your network administrator to verify that there is only one master browser and that browsing is functioning properly.
A required privilege is not held by the client.
[Kernel32]
An application has requested a service that it does not have the privilege to perform. Most, but not all, system services check the client's privileges before performing a requested service. For example, no privilege is required to get the system time, but a privilege is required to set the system time.
Ask your system administrator for the privilege to use the service.
A response keyname in the device .INF file is not in the expected format.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
A retry was successful on name.
A retry succeeded on the named device.
You can ignore this message. It is for informational purposes only.
A SCSI tape device has been detected, but the tape driver has either not been installed, or failed to start. Make sure that the appropriate driver has been installed using the Add/Remove Tape Devices option in the Options menu of Windows NT Setup.
[Backup]
To run Backup, you must install the appropriate device driver.
Follow the action specified in the message.
A sector failure occurred on accesses to both copies of the data.
[Disk Administrator]
An I/O operation failed for both the primary and the redundant copy of the data. It is unlikely that bad spots have appeared at the same offset on both disks.
Make sure the drives are on-line and are functioning properly. Check for Eventlog entries close to this one that indicate a hardware problem with one or both drives.
A security descriptor is not in the right format (absolute or self-relative).
[Kernel32]
Contact the supplier of the running application.
A seeding adapter had no network range specified for adapter "name ".
[Services for Macintosh (SFM)]
The seeding adapter setting was deleted by directly accessing the Registry instead of using the Network option in Control Panel.
Use the Network option in Control Panel to correct the configuration of the seeding adapter. Select Services for Macintosh and then choose Configure. Check the Enable Routing check box and then choose Advanced. Check the Seed this Network check box.
A seeding adapter had no zone list specified on adapter "name ".
[Services for Macintosh (SFM)]
The seeding adapter setting was deleted by directly accessing the Registry instead of using the Network option in Control Panel.
Use the Network option in Control Panel to specify a zone list for the adapter. Select Services for Macintosh and then choose Configure. Check the Enable Routing check box and then choose Advanced. Check the Seed this Network check box.
A seeding adapter had too many zones specified on adapter "name ". The limit on zones is 255.
[Services for Macintosh (SFM)]
The seeding adapter setting was changed by directly accessing the Registry instead of using the Network option in Control Panel.
Use the Network option in Control Panel to remove zone from the adapter. Select Services for Macintosh and then choose Configure. Check the Enable Routing check box and then choose Advanced. Check the Seed this Network check box.
A server message block (SMB) error occurred on the connection to computer name.The SMB header is the data.
[Network] Net Message ID: 3192
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. An error occurred on a request that was sent to the specified server. The workstation may have been connected to a resource that is no longer shared.
Ask a network administrator to reshare the resource so that you can use it. If this solution fails, contact technical support.
A service specific error occurred: code.
[Network] Net Message ID: 3547
A service-specific error occurred.
Refer to the Help or documentation for that service to determine the problem.
A session does not exist with that computer name.
[Network] Net Message ID: 2312
The specified computer does not have a session with the server.
Check the spelling of the computer name. To display a list of workstations and users that have sessions with the server, type NET SESSION.
A signal is already pending.
[Kernel32]
This signal could not be posted because the process has another signal to process.
Try again at a later time.
A specified authentication package is unknown.
[Kernel32]
Contact the supplier of the running application.
A specified privilege does not exist.
[Kernel32]
Contact the supplier of the currently running application.
A spooler memory allocation failure occurred.
[Network] Net Message ID: 2165
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The spooler ran out of memory.
To free memory for the spooler, delete one or more printer queues or print jobs, or remove one or more printers from all print queues on the server.
A stop control has been sent to a service which other running services are dependent on.
[Kernel32]
The service stop control sent by a custom service management user interface program was ignored.
Stop the dependent services first, then retry the stop request.
A stripe set or volume set member listed in the configuration information was missing.
[Disk Administrator]
Check the cables to your disk drives. Then restart your computer. If you still get this message, contact technical support or your disk vendor to run hardware diagnostics on your disk drives.
A subdirectory or file name already exists.
[Command]
At the command prompt, you used the Md command to attempt to create a directory that already exists on the current drive.
Use the Md command and after the command, specify a unique directory name.
A subdirectory or file name already exists.
[Command Prompt]
At the command prompt, you used the Md command to attempt to create a directory that already exists on the current drive.
Use the Md command and after the command, specify a unique directory name.
A system error has occurred.
[Network] Net Message ID: 3056
The system error may be an internal LAN Manager or Windows NT error.
If the error code is Error 52, you need to delete the duplicate domain name in the [othdomains] section of your configuration file. If an error code beginning with NET is displayed, you can use the Helpmsg command to see more information about the error as follows: NET HELPMSG <message>#, where <message># is the actual error number. If no error number was displayed, contact technical support.
A tape access reached a filemark.
[Kernel32]
Contact the supplier of the running application.
A tape access reached the end of a set of files.
[Kernel32]
No user action is possible. If the application does not continue to run, contact the supplier of the application.
A tape device has been detected, and the tape driver started. However, the tape device is not responding. Check that tape device power is on and cables are properly connected.
[Backup]
Backup is not functioning properly.
Follow the action specified in the message.
A thread could not be created.
[WINS Service]
The WINS server is low on resources.
Reboot the WINS server. Also, check available disk space on that computer, and delete some files if necessary.
A thread could not be created for the service.
[Kernel32]
An application tried to start a service which requires a thread, but no threads were available. The service did not start.
Stop running some nonessential programs, then try to start the service again. You may need to get more memory for you computer.
A thread for the new service could not be created.
[Network] Net Message ID: 2194
The system temporarily could not access the resources it needed.
Try the command again later.
A transport driver received a frame which violated the protocol.
Check the device cabling, particularly the SCSI termination. After that, if you still get this message, run hardware diagnostics. You may have to contact the vendor of the device, and you may have to replace the controller, the disk drive, or both.
A TrueImage Interpreter error occurred for which no error string is defined.(Document Name: name ), Error Code: code
[Services for Macintosh (SFM)]
Contact technical support.
A TrueImage Interpreter frame buffer memory allocation failed.(Document Name: name )
[Services for Macintosh (SFM)]
The server may be running out of memory or resources.
Try stopping other running applications. You might also need to remove unused files and applications from the server's disk.
A user's session with this server has been deleted because the user's logon hours are no longer valid.
[Network] Net Message ID: 2434
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. LAN Manager ended a user's session with this server because the user's logon time expired.
No action is needed. To define the times during which a user can access the server, type NET USER <user name> /TIMES:<times>.
A valid name was not entered.
[Network] Net Message ID: 3735
You typed an invalid name.
Type a valid name.
A valid password was not entered.
[Network] Net Message ID: 3734
You typed an invalid password.
Type a valid password.
A WINS RPC thread encountered an exception.
[WINS Service]
Other activity on the computer has affected the activity of the specified thread. WINS will try to recover from the exception automatically.
No action is needed. If this error occurs often, stop and restart the WINS service.
A WINS thread could not reset a handle.
[WINS Service]
Other activity on the computer has affected the activity of the thread. WINS will try to recover from the exception automatically.
No action is needed. If this error occurs more than once, reboot the computer.
A WINS thread could not signal a handle.
[WINS Service]
No action is needed. If this error occurs more than once, reboot the computer.
A WINS thread could not signal the main thread after closing its session. This would be the last thread in WINS closing the database.
[WINS Service]
An error occurred that affects the successful closing of the database. This could result in a corrupt database.
Stop and restart WINS. You may need to restore the database from a backup.
A WINS worker thread encountered an exception.
[WINS Service]
Other activity on the computer has affected the activity of the specified thread. WINS will try to recover from the exception automatically.
No action is needed. If this error occurs often, stop and restart the WINS service.
A word is expected text the operator text. Your query was missing this word or used a word which isn't in the Search word list.
[Disk Administrator]
The command is not complete as you typed it and cannot be carried out without further information.
A worker thread could not be created.
[WINS Service]
The WINS server is running out of resources (probably disk space or memory).
Close some applications to free memory. Check available disk space and delete some files if necessary. Then stop and restart the WINS service.
A Worker thread is shutting down due to some error condition.
[WINS Service]
The WINS database might be corrupt.
Stop and restart the WINS service. If this message appears again, restore the WINS database from a backup copy.
A write fault occurred on the network.
[Kernel32]
An error occurred while data was being written to disk. Data might have been lost.
Ensure that the disk that you want to write to has enough space available, and that you have permission to write to the target file. Then retry the command.
A write fault occurred.
[Network] Net Message ID: 2295
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. LAN Manager found an error when writing to the message log file.
Contact your network administrator.
A write operation to filename failed. Data may have been lost.
[Network] Net Message ID: 3196
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. An attempt to write data to a file failed.
See if the specified disk is full. Also be sure that you have write permission for the target file.
A write-behind operation has failed to the remote server computer name. The data contains the amount requested to write and the amount actually written.
[Netevent]
Data may have been lost. Retry the command or action.
About to revert to the last known good configuration because the name service failed to start.
[Netevent]
A critical service or driver failed to start; therefore the system will revert to the last saved configuration.
Ask your system administrator to check the event log with Event Viewer for details about the service or driver errors that preceded this one.
Access Denied
[Registry Editor]
You attempted to access an object in Registry Editor without sufficient permission.
Use the Owner option to determine who owns the object, then see the owner to get permission to access it. If you are the owner, log onto a user account under which you have permission to access the object.
Access denied - filename
[Attrib]
You tried to write to a read-only file, or the file is already being used by another program or person on a network, or you don't have writing privileges for this file on a network.
Use the Attrib command to see if the file is read-only. If it is read-only and you want to write to this file, use the Attrib command with the -r switch to remove the read-only attribute. Otherwise, make sure another program isn't using this file. If you are on a network and you do have privileges for this file, another person may be using this file. Wait a while and then try again.
Access denied - filename
[Replace]
You tried to write to a read-only file, or the file is already being used by another program or person on a network, or you don't have writing privileges for this file on a network.
Use the Attrib command to see if the file is read-only. If it is read-only and you want to write to this file, use the Attrib command with the -r switch to remove the read-only attribute. Otherwise, make sure another program isn't using this file. If you are on a network and you do have privileges for this file, another person may be using this file. Wait a while and then try again.
Access denied - filename
[Xcopy]
You tried to write to a read-only file, or the file is already being used by another program or person on a network, or you don't have writing privileges for this file on a network.
Use the Attrib command to see if the file is read-only. If it is read-only and you want to write to this file, use the Attrib command with the -r switch to remove the read-only attribute. Otherwise, make sure another program isn't using this file. If you are on a network and you do have privileges for this file, another person may be using this file. Wait a while and then try again.
Access denied - filename
[Utilities]
You tried to write to a read-only file, or the file is already being used by another program or person on a network, or you don't have writing privileges for this file on a network.
Use the Attrib command to see if the file is read-only. If it is read-only and you want to write to this file, use the Attrib command with the -r switch to remove the read-only attribute. Otherwise, make sure another program isn't using this file. If you are on a network and you do have privileges for this file, another person may be using this file. Wait a while and then try again.
Access denied because username and/or password is invalid on the domain.
[Remote Access Service]
Type your username, password, and domain. If you are unsure of this information, ask your system administrator. If you do not specify a domain, the Remote Access server attempts to verify your username and password on the domain of which it is a member.
Access Denied.
[Backup]
You do not have permission to view the contents of the tape.
Access denied.
[File Manager]
You have attempted to access a file that you do not have permission to access.
Contact your system administrator or the owner of the file or directory. If you are the owner of the file, log on under the user account that you used to assign permissions on the file.
Access denied.
[Xcopy]
The volume is already being used by another program, or you don't have privileges to open the volume.
Make sure another program isn't using this volume, and that you have privileges to open the volume.
Access denied.
[Utilities]
The volume is already being used by another program, or you don't have privileges to open the volume.
Make sure another program isn't using this volume, and that you have privileges to open the volume.
Access Denied. Granted access = text, Error code: code
[Dynamic Data Exchange]
You have only the access permissions indicated. This is not sufficient for the access you tried to perform.
You can ask that your permissions be changed to allow the desired access.
Access is denied
[Dynamic Data Exchange]
You do not have the necessary permissions to access the desired resource.
You can ask that your permissions be changed to allow the desired access.
Access is denied.
[Kernel32]
One of the following has occurred: (1) the file is marked read-only; (2) the resource, such as a file or subdirectory, that you tried to access is in use, or the named pipe, queue, or semaphore is a shared resource in use; (3) you tried to access a resource or to perform an action for which you do not have sufficient privilege; (4) the filename is incorrect.
Do one of the following, then retry the command: (1) use the Attrib command to change the read-only attribute; (2) try to access the resource again later; (3) log on with sufficient privilege (if you do not have sufficient privilege, request it from the administrator who controls access); or (4) correct the filename.
Access is denied. You must be logged on with Administrative privilege to run Disk Administrator.
[Disk Administrator]
If there are no hard disks attached to the system, there exists on the system no entity for Disk Administrator to administer.
Beyond that specified in the message itself, no action is needed.
Access to the extended attribute was denied.
[Kernel32]
Check your access rights with your system administrator. You may need to contact the supplier of the running application.
Access to the specified device, path or file is denied.
You attempted to access an Object Packager object that you do not have the right to access.
Contact your system administrator. Or contact the owner of the package.
Access to the specified device, path or file is denied.
[Task Manager]
Ask the network administrator to set the permissions on this device or file, or on the directories in the path to the device or file, to allow you access.
Access to the specified device, path, or file is denied.
The 16-bit compatibility subsystem tried to load an application, but access was denied. Access may have been denied to the file, or to the directory or device that contains the file.
Ask your system administrator for permission to access the device, path, or file.
Accessing Registry DDE Share information failed
[Dynamic Data Exchange]
DDE Share information could not be found in the Registry. You might not have permission to access a key in the registry. The key involved is either HKEY_LOCAL_MACHINE\Software\Microsoft\NetDDE or HKEY_CURRENT_USER\Software\Microsoft\NetDDE.
An experienced user of Regedit32 should check the permissions on these keys. Or, that person can delete the key and then run Setup to re-configure these keys.
Account name was not found.
[User Manager]
Make sure you have the correct user account name. Then try again, making sure to type the name correctly.
Account Deleted
[User Manager]
You tried to change the file or directory permissions for an account, but the account has been marked for deletion.
No action is needed.
Account Unknown
[Network]
There is no user account by this name in this group. In some cases this message will appear if the account has been deleted or if no primary or backup domain controller can be reached on the user's domain.
Check that you have the correct name. Then try again, taking care to type the name correctly.
Account Unknown
[User Manager]
Permissions have been associated with Security ID number, but no other account information could be found for that number. The account might be on a domain that is no longer trusted, or on a domain that cannot be reached at the moment. Or the account might have been deleted.
No action is needed.
ACLCONV cannot determine the file system on target volume.
[Aclconv]
Aclconv can only convert permissions for an NTFS volume. Since it cannot determine whether this is an NTFS volume, it did not convert permissions.
Make sure that the specified drive name is valid and that you have permission to access it.
ACLCONV cannot restore permissions onto drive drive letter
[Aclconv]
Aclconv could not find the drive specified.
Make sure that the drive name is valid.
Active connections still exist.
[Network] Net Message ID: 2402
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. You tried to delete a network connection that has an active process, or you tried to log off while you have an active process.
Be sure that the processes running on a server are completed before you break the connection to that server, and that processes on all remote servers are completed before you log off.
Add list box item failed.
[Remote Access Service]
There was a problem allocating memory.
Adjusting instance tags to prevent rollover on file filename.
[Chkdsk]
CHKDSK is adjusting an internal file system structure for greater reliability. Each attribute record in an NTFS file record segment (FRS) has a unique tag ID. If the counter used to assign tag IDs for a particular FRS rolls over, duplicate tags would be created for different attribute records. This would mean that a routine that fetches attribute records could get the wrong record which could result in a loss of data.
No action is needed.
AFP information on "filename " was corrupted.
[Services for Macintosh (SFM)]
The file information is corrupted.
The defaults were set so no action is needed.
After starting, the service hung in a start-pending state.
[Kernel32]
Contact the supplier of the running application.
All AppleTalk routing configuration information for this computer will be lost. Are you sure you want to disable routing?
[Services for Macintosh (SFM)]
If you select Yes, all seeding information that you have specified will be lost. The AppleTalk® protocol routing will be according to the configuration of the network.
All available drive letters are already assigned. You will not be able to access the name from Windows NT unless you rearrange drive letter usage. Do you wish to continue and create the name anyway?
[Disk Administrator]
You can assign only 24 drive letters for accessing the volumes that you create (drives A and B are reserved for floppy disk drives). You have used up these 24 letters.
Either delete some drives, or remove the letter from one of your existing drives and assign it to the one that you want to create.
All COM ports are being used. Remove a device connected to one of the ports and try again.
[Terminal]
You attempted to configure a COM port for a device, and all of the available COM ports are being used.
When you have removed a device, return to the Communications dialog box and select None. This selection will cause Terminal to check the ports until it reaches the one that is available.
All copies of first block of bad block list bad on tape, cannot use this tape. From device: name
[QIC117]
This tape is corrupt.
Use a different tape.
All data in the mirror will be lost! Are you sure you want to break the selected mirror and delete its component partitions?
[Disk Administrator]
When you choose to break a mirror, Disk Administrator presents you with this standard confirmation message.
If you want to break the mirror, choose Yes. If not, choose No to return to the Disk Administrator window.
All data in the partition or logical drive will be lost! Are you sure you want to delete the chosen partition or logical drive?
[Disk Administrator]
When you choose to delete a partition or a logical drive, Disk Administrator presents you with this standard confirmation message.
If you want to delete the partition or drive, choose Yes. If not, choose No to return to the Disk Administrator window.
All data in the stripe set will be lost! Are you sure you want to delete the selected stripe set?
[Disk Administrator]
When you choose to delete a stripe set, Disk Administrator presents you with this standard confirmation message.
If you still want to delete the selected stripe set, choose Yes. If not, choose No to return to the Disk Administrator window.
All data in the volume set will be lost! Are you sure you want to delete the selected volume set?
[Disk Administrator]
When you choose to delete a volume set in Disk Administrator, you are presented with this standard confirmation message.
If you want to delete the volume set, choose Yes. If not, choose No to return to the Disk Administrator window.
All drive letters are already assigned.
[Disk Administrator]
Disk Administrator allows you to assign only 24 drive letters, and all of these are assigned.
Remove a drive letter from one of the existing volumes, and assign the letter to the volume that you want to create.
All handles to windows in a multiple-window position structure must have the same parent.
[Kernel32]
Contact the supplier of the running application.
All NTFS boot sectors are unreadable. Cannot continue.
[NTFS]
When both boot sectors on an NTFS disk partition are unreadable, the entire partition is inaccessible.
This is extremely unlikely to happen. But if it does, a work-around is to repartition the disk so at least one boot sector is on a readable portion of the disk. You may want to contact the hardware supplier.
All NTFS boot sectors are unwriteable. Cannot continue.
[NTFS]
Neither boot sector could be written to the NTFS partition. The disk may be in an inconsistent state.
Contact the disk hardware supplier.
All pipe instances are busy.
[Kernel32]
The pipe cannot be accessed because another process is using it.
Try the operation again later.
All system timers are currently being used by other applications. Quit one or more applications, and then try again.
[Terminal]
You attempted to activate the Timer Mode option from the Settings menu when other applications are using all system timers.
Follow the user action specified in the message.
All user accounts in a domain belong to its Domain Users global group. This membership list cannot be displayed.
[Network]
This group is never displayed because it is usually too large to display successfully.
No action is needed.
All zones in the zone list will be removed. Do you want to continue?
[Services for Macintosh (SFM)]
If you select Yes, you will be unable to seed the network. Seeding requires that a default zone be specified. You will be unable to specify a default zone if you remove the entire zone list.
Leave at least one zone in the list.
Already connected to name, use disconnect first.
[FTP Server]
While running the Ftp command, Ftp attempted to connect to a host it was already connected to
Disconnect from the remote host named in the message, and then retry the Ftp command.
Amount of data in received packet does not match the size specified in the header. Source address, Destination address, Protocol name,Specified size number, Actual size number.
[Netevent]
The network received an invalid packet and discarded it.
Ask your system administrator to correct the packets generated by the computer at the specified source IP address.
An AARP packet could not be sent on adapter "name ".
[Services for Macintosh (SFM)]
An AppleTalk Address Resolution Protocol packet could not be sent due to insufficient resources.
The packet will be resent subsequently. However, if you see this message frequently, increase the server's memory.
An AARP packet was not completely available in the look ahead data from NDIS on adapter "name ".
[Services for Macintosh (SFM)]
The adapter is not working properly. The AppleTalk Address Resolution Protocol may not be able to communicate with some computers.
Check the Event Log in Event Viewer for messages related to this one. Try a different adapter if the specified adapter cannot communicate with a computer on the network and you see this message frequently.
An abnormal error was encountered during WINS initialization.
[WINS Service]
While WINS was trying to start, it encountered an error that it does not normally encounter at that time. The error prevented WINS from starting.
Check the Event log to find out what error WINS encountered. Then take the appropriate action for that error.
An addressing error occurred in the RPC server.
[Kernel32]
In a distributed (RPC) application, a memory addressing error occurred at a server.
Contact the supplier of the running application.
An Alert condition has occurred on Computer: computer name ; Object: name ; Counter: name ; Instance: number ; Parent: name ; Value: number ; Trigger: name
[Performance Monitor]
Performance Monitor has been set to generate an alert when these conditions occur.
Take the appropriate action for these conditions. If you want, use Performance Monitor to view the alert log or to change the criteria for alerts.
An application has attempted to allocate Expanded Memory, which cannot be supported. This may cause the application to function incorrectly.
[Virtual DOS Machine (VDM)]
Try to ignore this message. If you are able to continue, you might want to check the results of the running application. Otherwise, contact the supplier of the running application.
An application has attempted to directly access the hard disk, which cannot be supported. This may cause the application to function incorrectly.
[Virtual DOS Machine (VDM)]
Choose to ignore the message. The particular application you are running might retain all the functionality you need after the functionality that depends on direct access to the hard disk is taken away. In the case of other applications, you will have to run them directly under MS-DOS or Windows 3.1.
An application has attempted to load a 16-bit MS-DOS device driver, which cannot be supported. This may cause the application to function incorrectly.
[Virtual DOS Machine (VDM)]
Block-mode device drivers, such as RAM disk drivers, are not supported. To find out which driver is not supported in your case, insert an Echoconfig command in your CONFIG.NT file and restart the virtual DOS machine. As each CONFIG.NT file command is executed, it will be echoed on the screen.
The particular application you are running may be able to run without this driver.
An application has attempted to perform an unknown internal 'BOP' opcode, which cannot be supported. This may cause the application to function incorrectly.
[Virtual DOS Machine (VDM)]
Try to ignore this message. If you are able to continue, you might want to check the results of the running application. Otherwise, terminate the application, then restart it. If you still get this message, contact your technical support group or the supplier of the running application.
An application has attempted to use a third-party mouse driver, which cannot be supported. This may cause the application to function incorrectly.
[Virtual DOS Machine (VDM)]
Contact the supplier of the third-party mouse driver and check whether it has been rewritten to run under Windows NT. If not, delete any reference to it in your CONFIG.SYS and/or CONFIG.NT files.
An ARP request was received for IP address address on network name.
[Netevent]
The network received an ARP request that specifies an invalid address.
Ask your system administrator to correct the packets generated by the computer at the specified source IP address.
An asynchronous request is pending.
[Remote Access Service]
This error should not occur under normal circumstances.
Restart your computer to make sure that all recent configuration changes have taken effect. If the error persists, consult the Windows NT event log for detailed warnings or errors.
An attempt by RASSER.DLL to get an async media access control handle failed.
[Remote Access Service]
The async media access control handle driver either is not loaded or cannot be opened.
Restart your system. If the problem persists, remove and reinstall the Remove Access Service using the Network option in Control Panel.
An attempt has been made to operate on an impersonation token by a thread that is not currently impersonating a client.
[Kernel32]
Only impersonation threads can call a service to create a new object without supplying a security token.
Contact the supplier of the running application.
An attempt to connect to the remote WINS server with address address returned with an error. Check to see that the remote WINS server is running and available, and that WINS is running on that server.
[WINS Service]
Make sure the remote WINS server is on the network and running WINS.
An attempt was made to establish a session to a network server, but there are already too many sessions established to that server.
[Kernel32]
There may be multiple logon sessions established on a LAN Manager server, but there is a limit to the number and that limit has been reached on the server you are attempting to logon to.
Wait for a session to end, and try again.
An attempt was made to exceed the limit on the number of domains per server.
[Kernel32]
Contact the supplier of the running application.
An attempt was made to logon, but the network logon service was not started.
[Kernel32]
Use the Services icon in Control Panel to check the status of the Net Logon service on your local computer. If it is not started, start it and retry the operation. If the service was started on your computer, the source of this message will be a remote computer. Contact the network administrator to start the Net Logon service on remote computers you are trying to use.
An attempt was made to move the file pointer before the beginning of the file.
[Kernel32]
Contact the supplier of the running application.
An attempt was made to reference a token that does not exist.
[Kernel32]
Contact the supplier of the running application.
An attempt was made to remember a device that had previously been remembered.
[Kernel32]
The connection request was rejected because the local device already has a remembered connection to a different network resource.
Either attempt to make the connection again, without having the computer remember it, or delete the existing remembered connection information.
An error has occurred from which WINS will try to recover. If recovery fails, check previous Event log entries to determine what went wrong, and take appropriate action on that error.
[WINS Service]
If WINS is unable to recover from the error, check previous entries in the Event log and take appropriate action on the error or errors preceding this message.
An error has occurred in the registry. The Program Manager's settings and groups can not be accessed.
[Program Manager]
An error in the Registry makes it impossible for Program Manager to read a program group's settings.
Restart your system. If Program Manager's settings and groups still cannot be accessed, contact technical support.
An error has occurred while printing. Make sure the printer is properly configured and selected.
[File Manager]
To check the configuration of your printer, exit or minimize File Manager, then use Print Manager to properly configure your printer.
An error has occurred. ClipBook Viewer cannot complete this procedure.
[Clipboard]
An internal software error has occurred.
Try restarting Windows NT, and then try again. If this message reappears, contact technical support.
An error has prevented wins from updating the database. the database may be corrupt.
[WINS Service]
Restore the database from a backup copy, and then pull data from the WINS server's push partner.
An error occurred trying to find a mark in the INF file.
[Remote Access Service]
RAS has three .INF files, MODEM.INF, PAD.INF, and SWITCH.INF. One of these files may be corrupted which is why the mark or line location cannot be found in the file. RAS cannot be configured.
Compare the RAS .INF files in your \<systemroot>\system32\ras directory with the distributed RAS .INF files.
An error occurred while reading your profile.
[Network] Net Message ID: 3679
Ask your system administrator to check your user profile.
An error occurred while saving the changes. Some changes will not be remembered.
[Program Manager]
The new settings could not be saved to the Registry, probably due to very low memory.
If some of the changes you made don't appear, use the Control Panel to make the changes again. If the problem persists, close some applications and try again.
An error occurred while saving the changes. Some changes will not be remembered.
[Program Manager]
If some of the changes you made don't appear the next time you log on, make the changes again.
An error occurred while setting a mark on a section in the INF file.
[Remote Access Service]
The server is running out of memory.
Try stopping other running applications and services. Also try removing and reinstalling RAS and restarting the server. If you continue to see this message, contact technical support.
An error occurred closing file filename. Please check the file to make sure it is not corrupted.
[Network]
Try to open the file using the appropriate application, and examine it to make sure no part of the file is missing or garbled.
An error occurred during construction of a control. The system may be low on resources or memory.
[WINS Service]
You will probably be unable to use the dialog box
Close some applications and try again.
An error occurred during translation of data to or from the tape in drive letter.
[Backup]
There was some problem with the data returned by the tape drive. The data on the tape or the tape drive may be lost.
Check the tape drive's cabling connections. If you continue to receive this message, contact the supplier of the tape drive.
An error occurred in sending the command to the application.
[File Manager]
Attempt to perform the action again. If this message reappears, quit and restart File Manager.
An error occurred in the domain message processor.
[Network] Net Message ID: 2280
An error occurred when the workstation was receiving or processing a domain-wide message.
Check the workstation's Event log by selecting System from the Log menu using Event Viewer. Stop and restart the Messenger service. If the problem persists, contact technical support.
An error occurred reading from or writing to the disk. The disk is unusable.
[Repair Disk]
Try again with a different disk.
An error occurred sending the command to the application.
[Program Manager] [Task Manager]
Program Manager is unable to start the application.
Try again. If this does not work, close the applications that you have running, and restart your system.
An error occurred when attempting to run the service program.
[Network] Net Message ID: 3061
The service you specified could not start.
In the [services] section of your configuration file, find the name of the program file for this service. Be sure this file exists and is an executable file with a filename extension of .EXE or .COM. If the program file exists, it may be damaged. If possible, restore the file from a backup version. Otherwise, contact technical support.
An error occurred when communicating with a Run server.
[Network] Net Message ID: 2389
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. LAN Manager found a problem while trying to complete the task.
Type the command again in a few minutes. If you continue to receive this message, see your network administrator.
An error occurred when opening network device driver name = name.
[Network] Net Message ID: 3406
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The listed device driver could not be installed.
Check that the listed entry in the [networks] section of the LANMAN.INI file is valid. In the CONFIG.SYS file, check the DEVICE entry that loads this device driver--the parameters of that entry may not be correct. Also check that the DEVICE entry specifies the correct path of the device driver.
An error occurred when opening or reading the configuration file.
[Network] Net Message ID: 2131
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The configuration file is missing or contains invalid information.
Ask your network administrator to review the contents of the configuration file.
An error occurred when reading the NETWORKS entry in the LANMAN.INI file.
[Network] Net Message ID: 3401
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. LAN Manager could not read the entries in the [networks] section of the LANMAN.INI file.
Be sure that the LANMAN.INI file exists (in the LANMAN directory). Check the format of the entries in the [networks] section.
An error occurred when starting a background process.
[Network] Net Message ID: 2391
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. LAN Manager found a problem while trying to complete the task.
Type the command again in a few minutes. If you continue to receive this message, see your network administrator.
An error occurred when the share was deleted.
[Network] Net Message ID: 3725
An error occurred when Windows NT tried to stop sharing the resource.
Try again to stop sharing the resource. If no more information about this error is displayed, use Event Viewer to read the system log. If no information appears in Event Viewer and the problem persists, contact technical support.
An error occurred while attempting to recover data from the fault tolerance set containing text.
[Disk Administrator]
There is a bad sector on one of the disks on one side of the mirror set. Your data security is at some risk. There is still a good sector on the other side of the mirror set, and the probability that the same sector number will go bad on both sides of the mirror is quite low.
To regain complete data security, do the following: (1) examine the event logs to identify which drive has the bad sector; (2) back up all data on that drive; (3) reformat the drive using the verify switch to map out the bad sector; and (4) restore the backed up data.
An error occurred while loading or running the logon script.
[Network] Net Message ID: 2212
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The logon script for your account may contain unrecognized commands or commands that could not run.
Ask your network administrator to review your logon script.
An error occurred while loading the profile file.
[Network] Net Message ID: 2374
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The system could not open the profile.
The profile file may be damaged. Create a new profile. If you need assistance, contact your network administrator.
An error occurred while opening the Help file.
[Network] Net Message ID: 3710
Windows NT could not find a file of Help information.
Be sure the NET.HLP file is in the same directory as NET.EXE, which is usually in your system directory. This directory should also be on your search path (specified by the Path command). If you cannot find the Help file on your computer, contact your network administrator. Your administrator should copy the Help file from the Windows NT distribution disks to your computer.
An error occurred while processing the logon hours for user user name.
[PORTUAS]
The time zone for the Windows NT system must be the same as the time zone in the down-level system.
Contact technical support.
An error occurred while processing the workstation list for user user name.
[PORTUAS]
When PORTUAS was translating the list of workstations from the user accounts database to the Windows NT security database, the system ran out of memory or one of the workstations has an invalid name. Workstation or computer names must have between 1 to 15 characters, must not begin or end with a blank space, and must not contain any control characters. The names also must not contain any forward or backslashes ( \\ /), double backslashes (\\\), brackets ([ ]), angle brackets (< >), colons (:), semicolons (;), quotation marks ("), pluses (+), or equal signs (=), question marks (?), wildcards (*), or vertical bars (|).
Verify that the workstation names from the down-level user accounts database are valid.
An error occurred while restoring the connection to name.
[Network] Net Message ID: 3680
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. A persistent connection could not be restored. This usually occurs because the specified server is not available.
If you do not wish to maintain this persistent connection, type NET LOGON again and type NO when asked whether you want to attempt accessing this resource in the future. If you want to use the resource, attempt to connect when it becomes available, or type NET LOGON to log on again.
An error occurred while running format.
[Utilities]
Try another disk or another file system.
An error occurred while sending a message to user name.
[Network] Net Message ID: 3722
An error occurred when a message was sent to the alias you selected. An additional error message should follow this one. It will tell you what action to take to correct the error.
Follow the recommended action in the second error message.
An error occurred while synchronizing with primary domain controller computer name
[Network] Net Message ID: 3226
The local copy of the security database may be out of synchronization with that of the domain controller because an error occurred while the database was being updated.
Use the Synchronize With Domain option in Server Manager to synchronize the security databases.
An error occurred while updating disk configuration. Drive letter and fault tolerance information may be lost and/or some partitions may be inaccessible.
[Disk Administrator]
Windows NT tried to write to the partition table and could not.
Attempt to update your disk configuration again. Or contact your technical support group.
An error occurred while updating the logon or logoff information for user name.
[Network] Net Message ID: 3225
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The current logon statistics may not be accurate because an error occurred while the logon and logoff information was being updated.
No action is needed.
An error was encountered during an operation on the static data file filename.
[WINS Service]
Make sure the specified file exists and has Read privileges set for the user who started WINS. If the file is present and readable, open and examine it to make sure it is not corrupt.
An error was encountered during configuration or reconfiguration of WINS.
[WINS Service]
Take the action recommended by the message that accompanied this one. Then try again.
An error was encountered in the database. You might need to restore the database from a backup.
[WINS Service]
Restore the database from a backup copy. If this message appears often, call Microsoft Product Support.
An error was reported while attempting to initialize the monitor with the list of port information from the registry. The information is located in theSYSTEM\\CurrentControlSet\\Control\\Print\\Monitors\AppleTalk Printing Deviceskey. The data is the error code.
[Services for Macintosh (SFM)]
If you can, verify the port information in the Registry. If so, contact technical support.
An event could not be created
[WINS Service]
The WINS server is out of resources, probably disk space.
Delete some files and then reboot the computer.
An exception occurred in the service when handling the control request.
[Kernel32]
While handling a control request, the service attempted to access an illegal address.
Contact your technical support group.
An exception was encountered while trying send a push trigger notification to a remote WINS.
[WINS Service]
Something happened that kept this WINS server from sending a push trigger to its push partner. The failure might be due to a communications failure.
No action is needed. Another request will be sent to the push partner after the usual time interval has elapsed. If you want to, you can send a push trigger now, using the Replication Partners dialog box.
An exception was encountered while trying service a pull range request from a remote WINS.
[WINS Service]
A remote WINS server asked this server for a range of database records, but the local server was unable to process the request.
Check the Event log to find out what error preceded this message. Then take the appropriate action for that error. If you find nothing in the Event log that could prompt this error, call Microsoft Product Support.
An exception was encountered while trying to inform a remote WINS to update the version number.
[WINS Service]
Something happened that kept this WINS server from sending update information to another WINS server. The failure might be due to a communications failure.
Make sure that the other WINS server is running and that the router is running.
An extended error has occurred.
[Kernel32]
An application has returned a network-specific error code.
You will have to look at the documentation from the network provider to find the meaning of this network-specific error code.
An extended partition already exists on the disk.
[Disk Administrator]
You have attempted to create an extended partition on a disk on which an extended partition already exists.
Choose OK, then create an extended partition on another disk.
An extensible counter has closed the Event Log for RASCTRS.DLL
[Remote Access Service]
This message is for your information. It indicates the Event Log is being closed during the shutdown of the application.
No action is needed.
An extensible counter has opened the Event Log for RASCTRS.DLL
[Remote Access Service]
This message is only for your information. It indicates that the specified dynamic library initialized.
No action is needed.
An I/O failure occurred on name.
[Disk Administrator]
The specified name is a fault tolerance set member name; it refers to a fault tolerance partition.
Retry the operation. If you still get this message, contact technical support.
An I/O operation initiated by the Registry failed unrecoverably. The Registry could not read in, or write out, or flush, one of the files that contain the system's image of the Registry.
[Kernel32]
The system could not read in, write out, or flush one of the files that contain the system's image of the Registry, because of an unrecoverable I/O error.
Restart the system. You may have to use the Emergency Repair Disk to restore the system configuration information.
An illegal country code has been supplied.
[Network] Net Message ID: 3773
You typed an invalid country code.
Specify a valid country code
An illegal date format has been supplied.
[Network] Net Message ID: 3767
You used an illegal date format.
Retype the command with a correct date format. Dates should be typed in the form <mm/dd/yy> or <dd/mm/yy>, depending on the user's country code. Months can be represented by a number, spelled out, or abbreviated to exactly 3 letters. Use commas or slashes to separate the parts of the date--do not use spaces. If you do not specify the year, Windows NT assumes it to be the next occurrence of the date.
An illegal day range has been supplied.
[Network] Net Message ID: 3768
You specified an illegal range of days. You must also type a hyphen between the first and last days of each range.
When specifying days, use only the complete names of the days or valid Windows NT abbreviations. Valid abbreviations are M, T, W, Th, F, Sa, Su. Use a hyphen to separate the beginning and end of each range of days.
An illegal server message block (SMB) was received. The SMB is the data.
[Network] Net Message ID: 3112
A software error occurred.
Contact technical support.
An illegal time range has been supplied.
[Network] Net Message ID: 3769
You typed an invalid time range.
Retype the command with a valid time range. Use either the 12-hour format, with the numbers 0-12 and AM and PM, or the 24-hour format, with the numbers 0-24. Use a hyphen to separate the beginning and end of a time range, as in 9AM-4PM.
An inconsistency was encountered on the tape in drive letter.
[Backup]
There was some problem with the data returned by the tape drive.
Check the tape drive's cabling connections. If you continue to receive this message, contact the supplier of the tape drive.
An inconsistency was encountered on the tape in drive letter. Do not append to this tape.
[Backup]
When Backup detects a format inconsistency in a tape, it warns you against jumping to the end of the tape so that you will not risk losing data. You may be using a tape that Backup does not support.
Try a different tape.
An incorrect parameter was entered for the command.
[Command]
You specified a parameter that is not valid for this command.
To find out which parameters are valid for this command, type the Help command at the command prompt, followed by the name of the command on which you want help.
An incorrect parameter was entered for the command.
[Command Prompt]
You specified a parameter that is not valid for this command.
To find out which parameters are valid for this command, type the Help command at the command prompt, followed by the name of the command on which you want help.
An incorrect volume label was entered for this drive.
[Format]
As an added protection for hard drives, Format requires that you enter the drive's current volume label to make sure that Format is formatting the correct volume.
Check the current drive letter assignment to the drives and then specify the correct volume label. You can get this information from Disk Administrator.
An installable Virtual Device Driver failed DLL initialization.
[Virtual DOS Machine (VDM)]
Ask your system administrator to double-check the installation of the Virtual Device Driver on your computer. You may have to reinstall the dynamic-link library. After that, if you still get this message, contact the supplier of the dynamic-link library.
An installation file required by NTVDM is missing, execution must terminate.
[Virtual DOS Machine (VDM)]
The virtual DOS machine cannot start up because it is either unable to locate or to read the NTIO.SYS file.
Reinstall the NTIO.SYS file from your Windows NT distribution media (you will have to decompress the file). The file should be put in the Windows NT \systemroot\system32 directory.
An instance of the service is already running.
[Kernel32]
An application tried to start a service that is not in a stopped state. No more than one instance of a service may be running at a time on a computer.
There is no need to start a second instance of a running service.
An internal consistency error has occurred.
[Network] Net Message ID: 3057
A software error occurred.
Contact technical support.
An internal error -6002 occurred.
[Services for Macintosh (SFM)]
Error 6002 indicates that an invalid ID has been supplied by a component of Services for Macintosh.
Contact technical support.
An internal error -6003 occurred.
[Services for Macintosh (SFM)]
Services for Macintosh specified invalid parameters.
Contact technical support.
An internal error -6004 occurred.
[Services for Macintosh (SFM)]
An invalid code page value for the MACCP key is in the Registry.
Use the Network option in Control Panel to remove and reinstall Services for Macintosh. Otherwise, contact technical support.
An internal error -6008 occurred.
[Services for Macintosh (SFM)]
The Macintosh volume is read only.
Contact technical support.
An internal error -6011 occurred.
[Services for Macintosh (SFM)]
The buffer size may be too small.
Contact technical support.
An internal error -6015 occurred.
[Services for Macintosh (SFM)]
The server is in an invalid state.
Try restarting the server. If you continue to see this message, contact technical support.
An internal error -6024 occurred.
[Services for Macintosh (SFM)]
Too many Creator/Type extension mappings have occurred.
Contact technical support.
An internal error has occurred. Try configuring again.
[Services for Macintosh (SFM)]
A memory allocation failure occurred or Registry entries were removed when configuring the system.
Reconfigure Services for Macintosh using the Network option in Control Panel. Also try restarting the system.
An internal error occurred in a remote procedure call (RPC).
[Kernel32]
There is a programming error in the distributed RPC application. The error could have occurred on either the client side or the server side.
Contact the supplier of the running application.
An internal error occurred while accessing the computer's local or network security database.
[Network] Net Message ID: 5602
Either Windows NT did not install properly or the local or network security database is corrupted.
If you receive this message after your initial installation of the operating system, reinstall Windows NT. Otherwise, contact your network administrator.
An internal error occurred. The network cannot access a shared memory segment.
[Network] Net Message ID: 2104
An internal error occurred.
Contact technical support.
An internal Windows NT error occurred.
[Network] Net Message ID: 2140
A software error occurred.
Contact technical support.
An invalid AARP packet was received on adapter "name ".
[Services for Macintosh (SFM)]
An invalid AppleTalk Address Resolution Protocol packet was received on the network. The computer is malfunctioning.
Contact your network administrator to investigate.
An invalid adapter is configured to be the default adapter "name ". Localtalk adapters cannot be a default adapter in a routing configuration.
[Services for Macintosh (SFM)]
When routing is enabled on Services for Macintosh, only non-LocalTalk adapters can be set as the default adapter.
Use the Network option in Control Panel to set a non-LocalTalk adapter as the default adapter.
An invalid or nonexistent alert name was raised.
[Network] Net Message ID: 2432
A software error occurred.
Be sure the Alerter service is started. If this error occurs while the Alerter service is started, contact technical support.
An invalid request was sent to the admin support thread for the Remote Access Service, possibly from a down-level admin tool. The request was not processed.
[Remote Access Service]
Restart your computer. If the problem persists, check your system's configuration, quotas, and resources. For further information, consult your Windows NT documentation.
An invalid zone name specified in the zone list for adapter "name ".
[Services for Macintosh (SFM)]
Zone names are invalid if they are greater than 32 characters. The zone name was incorrectly changed by directly accessing the Registry instead of using the Network option in Control Panel.
Use the Network option in Control Panel to specify a correct zone name for the adapter. Then, restart the computer for the changes to take effect.
An IO error has occurred.
[File Manager]
You tried to format or write to a disk that is not valid for writing.
Make sure that the disk is not read-only or write-protected. Then try again.
An operation failed while attempting to format the volume.
[Disk Administrator]
The volume was not formatted.
Check the event log for errors that occurred at about the same time as this one and that involved this volume or drive. Take the appropriate action on those errors, and try again.
An operation is pending.
[Remote Access Service]
This error should not occur under normal circumstances.
Restart your computer to make sure that all recent configuration changes have taken effect. If the error persists, consult the Windows NT event log for detailed warnings or errors.
An overrun occurred on name.
The named device continued to send data to a buffer, even though the buffer was full.
Retry the operation. If you still get this message, run hardware diagnostics on the disk drive named in the message, and on its controller. You may have to contact the vendor of the device, and you may have to replace the controller, the disk drive, or both.
An unexpected NetBIOS error occurred. The error code is the data.
[Network] Net Message ID: 3111
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. A software error occurred.
Contact technical support.
An unexpected network error has occurred on the virtual circuit to name.
[Netevent]
Wait a few minutes, then retry the command.
An unexpected network error occurred.
[Kernel32]
Your computer received an error from the network that was not expected in this situation.
Retry the operation. If you continue to have problems, contact your network administrator.
An unknown error has occurred reading from or writing to the disk. The disk is possibly unusable.
[Repair Disk]
Try again with a different disk. If you continue to see this message, there might be a hardware problem with your disk.
An unknown error occurred.
[Network]
Reinstall the component you were using when this error occurred.
An unknown error occurred.
[Services for Macintosh (SFM)]
Contact technical support.
Annotations are damaged; please exit WinHelp, delete filename and recreate annotations.
[Help]
When you annotate a Help topic, Help saves these annotations to a .ANN file. The file that is used to save these annotations is damaged and needs to be deleted.
Use the Annotate option on the Edit menu to recreate your annotations.
Another driver on the system, which did not report its resources, has already claimed the interrupt used by name.
A third party device driver has been installed that is taking the resource without informing the system that it has done so.
Remove the device. Notify the vendor of the device driver, and Microsoft, of this problem.
Another instance of Setup may already be running.
[Setup]
When you select OK, Setup will automatically exit. Then retry the Setup operation.
Another instance of Setup may already be running.
[Repair Disk]
When you select OK, Setup will automatically exit. Then retry the Setup operation.
AppleTalk is not bound to the adapter "name ". Request for the adapter ignored.
[Services for Macintosh (SFM)]
Choose the Network option in Control Panel to bind the protocol to the adapter. Select Services for Macintosh and then choose the Bindings button.
Are you sure you want to allow all users access to the System Partition?
[Disk Administrator]
To allow users to examine or copy system configuration files, some administrators prefer to permit a larger variety of users to access the System partition.
Are you sure you want to clear statistics?
[WINS Service]
You attempted to clear the statistics. This message allows you to change your mind if you want to.
If you are sure you want to clear the statistics, answer Yes. Otherwise, answer No.
Are you sure you want to close all file forks on computer name ?
[Services for Macintosh (SFM)]
Users could lose any unsaved data.
Use Server Manager or File Manager to send a disconnect message to users. In using either manager, select the MacFile menu. In Server Manager, select Send Message. In File Manager, select View/Modify Volumes and then select Send Message.
Are you sure you want to close the current connection?
[WINS Service]
You attempted to close a network connection. This message allows you to change your mind if you want to.
If you are sure you want to close this connection, answer Yes. Otherwise, answer No.
Are you sure you want to delete group ' group '?
[Program Manager]
You chose to delete a program group in Program Manager, and this is a standard confirmation message.
If you are sure that you want to delete the currently selected program group, choose Yes. If not, choose No to return to Program Manager.
Are you sure you want to delete item ' name '?
[Program Manager]
You chose to delete a program item in Program Manager, and this is a standard confirmation message.
If you are sure that you want to delete the currently selected program item, choose Yes. If not, choose No to return to Program Manager.
Are you sure you want to disconnect computer name from all connected resources?
[Server Manager]
You directed Server Manager to disconnect a user from the target server, and this is a standard confirmation message.
If you are certain that you want to disconnect the specified user from all connected resources, choose Yes. If not, choose No to return to the Shared Resources dialog box.
Are you sure you want to disconnect user name from all connected volumes?
[Services for Macintosh (SFM)]
The user could lose any unsaved data.
Use Server Manager or File Manager to send a disconnect message to the specified user. In using either manager, select the MacFile menu. In Server Manager, select Send Message. In File Manager, select View/Modify Volumes and then select Send Message.
Are you sure you want to disconnect all connected users?
[FTP Server]
If the connected user is disconnected from a computer on which he or she has files open, those files could be corrupted.
If you are sure you want to disconnect all connected users, choose Yes. You might want to choose No, advice all connected users to close files and disconnect, and then try again.
Are you sure you want to disconnect all users connected to the name share from all connected resources?
[Server Manager]
You chose to disconnect all users from a shared resource, and this is a standard confirmation message.
If you are sure you want to disconnect all users from the specified resource, choose Yes. If not, choose No.
Are you sure you want to disconnect all users connected to the Macintosh-Accessible volume name ?
[Services for Macintosh (SFM)]
Use Server Manager or File Manager to send a disconnect message to users. In using either manager, select the MacFile menu. In Server Manager, select Send Message. In File Manager, select View/Modify Volumes and then select Send Message.
Are you sure you want to disconnect all users from all connected resources?
[Server Manager]
You chose to disconnect all users from a all resources, and this is a standard confirmation message.
If you are sure you want to disconnect all users from all resources, choose Yes. If not, choose No.
Are you sure you want to disconnect all users from all connected volumes?
[Services for Macintosh (SFM)]
Disconnecting the users might cause them to lose unsaved data.
Are you sure you want to disconnect the user user name connected to the Macintosh-Accessible volume name ?
[Services for Macintosh (SFM)]
The user could lose any unsaved data.
Use Server Manager or File Manager to send a disconnect message to the specified user. In using either manager, select the MacFile menu. In Server Manager, select Send Message. In File Manager, select View/Modify Volumes and then select Send Message.
Are you sure you want to erase the tape in the drive ?
[Backup]
When you select the Erase Tape command on the Operations menu, Backup presents you with this confirmation message.
If you want to erase the tape, choose Yes. If not, choose No to return to the Backup window.
Are you sure you want to force user name to close name ?
[Services for Macintosh (SFM)]
The specified user could lose any unsaved data if forced to close the specified file.
Use Server Manager or File Manager to send a disconnect message to the specified user. In using either manager, select the MacFile menu. In Server Manager, select Send Message. In File Manager, select View/Modify Volumes and then select Send Message.
Are you sure you want to move the selected files or directories to name?
[File Manager]
Using the mouse, you attempted to move a file/directory, and this is a confirmation message. Or you attempted to move a file/directory to a different drive.
If you wish to complete the procedure, choose Yes. If not, choose No. If you don't want to see this message in the future, deselect the options in the Confirmation dialog box.
Are you sure you want to overwrite the filename file?
[Terminal]
You attempted to save the current settings file under a filename that already exists.
If you want to replace the previously existing file with the current file of the same name, select Yes. If not, select No. To return to Terminal, select Cancel.
Are you sure you want to pause the name service?
[Server Manager]
You directed Server Manager to pause a service on a computer, and this is a confirmation message. Be aware that if you choose Yes, no new user will be allowed to connect to the service. Currently connected users, however, will not be affected.
If you want to pause the specified service, choose Yes.
Are you sure you want to remove computer name from the list of domains and computers from which to import files?
[Server Manager]
You chose to remove a computer or domain from the list of domains and computers from which to import files, and this is a standard confirmation message.
If you are certain that you want to complete this operation, choose Yes. If not, choose No to return to the Directory Replication dialog box.
Are you sure you want to remove computer name from the list of domains and computers to which to export files?
[Server Manager]
You chose to remove a name from the list of domains and computers to which to export files, and this is a standard confirmation message.
If you are sure that you want to complete this operation, choose Yes. If not, choose No to return to the Directory Replication dialog box.
Are you sure you want to remove the subdirectory name from the list of sub-directories which are exported from this computer?
[Server Manager]
You chose to remove a subdirectory from the list of subdirectories that are exported from a server, and this is a standard confirmation message.
If you are sure that you want to remove the selected subdirectory, choose Yes. If not, choose No to return to the Manage Exported Directories dialog box.
Are you sure you want to remove the subdirectory name from the list of sub-directories which are imported to this computer?
[Server Manager]
You chose to remove a subdirectory from the list of subdirectories that are imported to a computer, and this is a standard confirmation message.
If you are sure that you want to complete this operation, choose Yes. If not, choose No to return to the Manage Imported Directories dialog box.
Are you sure you want to restrict access to the System Partition to System Administrators?
[Disk Administrator]
To prevent accidental or unauthorized changes to the system configuration, some administrators prefer to restrict access to the System partition.
Are you sure you want to start name using filename as the initial file?
[File Manager]
When you drag a text file onto a program file, Windows NT presents you with this confirmation message.
If you want to start the designated program file using the designated text file as the initial file, choose Yes. If not, choose No.
Are you sure you want to stop the name service?
[Server Manager]
In the Services dialog box, you chose to stop a service on a target computer, and this is a standard confirmation message.
If you are sure that you want to stop the service, choose Yes. If not, choose No to return to the Services dialog box.
Are you sure you wish to delete name ?
[Print Manager]
You chose to delete a printer, and this is a standard confirmation message.
Are you sure you wish to delete your connection to name ?
[Print Manager]
You chose to delete a connection to a printer, and this is a standard confirmation message.
Arg list too long text
Try again, using fewer arguments to the command.
Arguments to NET USER are invalid. Check the minimum password length and/or arguments supplied.
[Network] Net Message ID: 3770
You typed invalid options or variables with the command.
Retype the command using valid options and variables. When you add a user account, the password you set for the user must conform to your system's guidelines for password length.
Arithmetic result exceeded 32 bits.
[Kernel32]
Contact the supplier of the running application.
ARP cannot link to DataLink interface version number.
[Netevent]
TCP/IP and STREAMS versions do not match.
Ask your system administrator to load compatible versions of TCPIP.SYS and STREAMS.SYS.
ARP-datalink registration failed. Unable to allocate a number byte message.
[Netevent]
ARP could not initialize because of insufficient memory.
Stop other applications from running and retry the operation in few minutes. If the problem persists, your system administrator may need to add more memory to your system.
At initialization, WINS creates a security object and attaches an ACL to it. This security object is then used to authenticate RPC calls made to WINS. WINS could not create the above security object. In short, WINS could not initialize with the security subsystem properly.
[WINS Service]
The WINS service could not start.
Reboot the WINS server.
At least one of your network adapters has automatic DHCP configuration enabled. In order to correctly install the DHCP Server, setup will disable automatic DHCP configuration. Are you sure you want to install the DHCP Server?
[TCP/IP]
Only DHCP clients can be configured automatically. If you configure this computer as a DHCP Server, the configuration must be explicitly assigned.
Choose Yes to install DHCP Server, or choose No to cancel the operation.
Attempt to access invalid address.
[Kernel32]
Contact the supplier of the running application.
Attempt to change computer name failed; error was code
[Control Panel]
In the Network option in Control Panel, you attempted to change the name of your computer, and this attempt failed.
Consult the event log in Event Viewer for details. Then contact your system administrator.
Attempt to determine the number of Lanas failed.
[Dynamic Data Exchange]
The Network Dynamic Data Exchange utility was unable to find out how many Local Area Network adapters (LANAs) there are on this computer. It cannot be used to communicate over the network until it has this information.
Make sure you have at least one adapter card installed in this computer.
Attempt to leave old primary domain incomplete; error was code
[Control Panel]
In the Network option, you tried to leave your old primary domain, and this attempt failed.
Consult the event log in Event Viewer for details. Then contact your system administrator.
Attempt to move past end of tape
[Backup]
Backup attempted to move to a position on the tape that does not exist.
Check the Hardware Compatibility List for a compatible version of the tape drive. You might also want to contact technical support. Be sure to record any messages and information you see for them.
Attempt to release mutex not owned by caller.
[Kernel32]
You must be the current owner of a mutex semaphore in order to release it.
Request ownership of the mutex semaphore; then retry the command. You may have to contact the supplier of the running application.
Attempt to use a file handle to an open disk partition for an operation other than raw disk I/O.
[Kernel32]
Contact the supplier of the running application.
Attempted to add nonunicast IP address address to the ARP cache.
[Netevent]
ARP caches cannot receive broadcast messages.
Contact your system administrator or consult the ARP documentation.
Attempted to set a macro not listed in device .INF file section.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Audit attempt has failed.
This is a Windows NT Executive character-mode STOP message.
Restart and set the Recovery options in the System Control Panel or the /CRASHDEBUG system start option. If this message reappears, contact your system administrator or technical support group.
AutoRefresh is not available for remote registries; Registry Editor will disable AutoRefresh mode.
[Registry Editor]
This message appears when you attempt to select the Auto Refresh option while displaying windows from a remote Registry in Registry Editor. You cannot set Auto Refresh on a remote Registry.
No action is needed.
Bad 'Escape' operator.
[Fonts (CP)]
There is a problem with the font.
Contact the vendor of the font and report this message.
Bad arguments passed to a Setup support library routine
[Setup]
One of the Setup information (.INF) files may be corrupted, or something is wrong with the distribution media.
Contact the supplier of the Windows NT distribution media and get another copy.
Bad arguments passed to a Setup support library routine
[Repair Disk]
One of the Setup information (.INF) files may be corrupted, or something is wrong with the distribution media.
Contact the supplier of the Windows NT distribution media and get another copy.
Bad block detected (unrecoverable read error).From device: name
[QIC117]
Data might have been lost, due to a bad block on the tape.
Reformat the tape or use a new tape.
Bad clusters in EA file header relocated.
[Chkdsk]
Bad clusters in the extended attribute file have been replaced with clusters taken from free space on the disk. The bad clusters have been marked in the file allocation table so that they will not be reused.
No action is needed.
Bad command line syntax
[File Compare]
The Comp command contained too many filename parameters, or your response to the Option prompt was not preceded by a slash (/) character or a minus (-) character.
To check the syntax for this command, type HELP at the command prompt followed by the command name (in this case, Comp).
Bad data
[Backup]
The media may not be recognized by the tape drive media in the drive may be corrupted.
Make sure compatible media is in the drive. If not, try user an older version of the tape.
Bad numeric argument : number
[File Compare]
You did not supply a valid number for the /n switch with the Comp command. The number field can only contain numbers between 0 and 9.
Bad or missing LAN Manager root directory.
[Network]
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer.
Bad protocol option text
This option was mistyped or is not available for this command.
Make sure you have the correct syntax for the command. Then try again, making sure the command is typed correctly.
Bad prototype for routine.
[Help]
This error is from the Macro Language Editor for online help, and should not appear while using the Help file. Report this error to the provider of the Help file.
Bad routine name.
[Help]
This error is from the Macro Language Editor for online help, and should not appear while using the Help file. Report this error to the provider of the Help file.
Bad source disk specified on line number in section number.
[Setup]
Contact the supplier for another copy of the installation media.
Bad Window Class, ignored.
[Help]
This error is from the Macro Language Editor for online help, and should not appear while using the Help file. Report this error to the provider of the Help file.
Badly formed registry data on line number in section number.
[Setup]
Contact the supplier for another copy of the installation media.
Badly formed Setup UI Script Command.
[Setup]
When you select OK, Setup will automatically exit. First, retry the Setup operation from the beginning. If you get the same message and if you are running maintenance Setup, you can try replacing the .INF file with one from the distribution medium (you will have to decompress the file). Otherwise, contact your technical support group.
Badly formed Setup UI Script Command.
[Repair Disk]
When you select OK, Setup will automatically exit. First, retry the Setup operation from the beginning. If you get the same message and if you are running maintenance Setup, you can try replacing the .INF file with one from the distribution medium (you will have to decompress the file). Otherwise, contact your technical support group.
Beginning of tape or partition was encountered.
[Kernel32]
No user action is possible. If the application does not continue to run, contact the supplier of the application.
Binding algorithm failed
[Control Panel]
The Network option is currently unable to bind the components necessary for a usable network connection. A binding algorithm can fail because of an internal software error, or because the networking software produced inaccurate data.
Consult the event log in Event Viewer for details. Then contact your system administrator.
Binding algorithm query failed
[Control Panel]
The Network option in Control Panel is currently unable to bind the components necessary for a usable network connection. A binding algorithm query can fail because of an internal software error, or because the networking software produced inaccurate data.
Consult the event log in Event Viewer for details. Then contact your system administrator.
Binding preparation failed
[Control Panel]
The Networks option in Control Panel is currently unable to bind the components necessary for a usable network connection. A binding preparation can fail because of an internal software error, or because the networking software produced inaccurate data.
Consult the event log in Event Viewer for details. Then contact your system administrator.
Binding to SAP Socket failed. The Nw Sap Agent cannot continue.
[Netevent]
The application could not be started because a resource is in use by another application or otherwise unavailable. Often the problem is insufficient free memory.
Close one or more applications and try again.
Binding to wan socket failed. The Nw Sap Agent cannot continue.
[Netevent]
The application is unable to get status information about the Wide Area Network (WAN). Resources that are accessed via the SAP Agent and services that depend on the SAP Agent will not be available.
Call technical support. Report both this message and the message that accompanies it.
Binding too long.
[Help]
This error is from the Macro Language Editor for online help, and should not appear while using the Help file. Report this error to the provider of the Help file.
Bindings file specifies non-existent Registry key
[Control Panel]
The file that contains bindings information specifies a key in the Registry that does not exist.
Contact technical support.
Biplex port initializing. Wait a few seconds and redial.
[Remote Access Service]
This error can occur on a port configured for dialing out and receiving calls (biplex port). It happens when you dial out at the same time the server is initializing the port for receiving calls. Remote Access solves this problem for you by redialing in a few seconds.
Bookmark does not exist.
[Help]
The active application or the system has attempted to access a bookmark that does not exist.
In the Bookmark Define dialog box, select the name of an existing bookmark.
Bookmark with this name already exists.
[Help]
In the Bookmark Define dialog box, you attempted to assign to a bookmark the name of an already existing bookmark.
Assign the new bookmark a unique name.
Bookmarks are damaged; please exit WinHelp and delete WINHELP.BMK.
[Help]
The WINHELP.BMK file is located in your Windows NT SYSTEM32 directory.
Delete this file, then restart Help.
Boot-start or system-start driver ( name ) must not depend on a service.
[Netevent]
A boot-start or system-start driver is dependent on another driver or service to start. These drivers should depend only on a group.
Ask your system administrator to change the dependency to refer to a group rather than another driver.
Bus reset
[Backup]
If your tape drive uses the same controller as your SCSI device and the SCSI device times out, the controller driver resets the bus. This is fatal to tape drives.
Try putting your tape drive on a separate controller.
Caller's buffer is too small.
[Remote Access Service]
This error should not occur under normal circumstances.
Restart your computer to make sure that all recent configuration changes have taken effect. If the error persists, consult the Windows NT event log for detailed warnings or errors.
Can not install typeface due to copyright. Copyright holder: name
[Fonts (CP)]
The font cannot be installed because the system has not obtained the right to do so.
Contact the vendor of the font and report this message.
Can only search on text containing no more than 255 characters. Search for the first 255 characters entered?
[Write]
Choosing the Find option, you specified a search criteria longer than 255 characters. Write will only search on the basis of the first 255 characters specified.
To initiate the search on the basis of the first 255 characters that you have entered, choose Yes.
Can't access a needed shared library name
The operation cannot continue until the library file is accessed.
Make sure that the library file exists and that your process has permission to read the file and any directories that the file is in. Then try again.
Can't access user settings.
[Telnet]
The file in which your user settings were saved is probably missing or corrupt.
Use the Options menu to establish and save your settings.
Can't find file filename
[Print]
Make sure the file you specified in the Print command exists in the specified directory, and that you typed the filename and path correctly. If this message appears on the printer screen, the file has been removed, renamed, or deleted between the time it was queued for printing and the time it actually began printing.
can't find list of remote files, oops
[FTP Server]
The Ftp command was unable to retrieve the list of remote files to transfer.
Check the path and filename spelling used in the Ftp command against the actual name and location of the remote file list. If there is no problem there, contact your network administrator.
Can't find/open file: filename
[File Compare]
Make sure the filename is correct, and that it is not the name of a directory.
Can't nest calls to LoadModule.
[Kernel32]
Contact the supplier of the running application.
Can't open input file: filename.
[Command Prompt]
The specified file cannot be opened. There may be too many files open already, the path may not be valid, and the destination filename may be the same as an existing directory name. Also, the file may be read-only, locked, or on a write-protected disk.
Make sure you have correctly specified the path and filenames, and that the filename is not the same as an existing directory name. Use the Attrib command to see if the file is read-only, and make sure the Share command has not locked the file. If the destination file is on a floppy disk, make sure the disk is not write-protected. If you have other files open, close some files so the new file can be opened.
Can't read file: filename
[File Compare]
The Comp command cannot read the specified file.
Make sure the file is not locked or in use by another program. The file might also be corrupted or located on a bad sector. If this is the case, use a backup copy of the file.
Can't read from input file: filename.
[Command Prompt]
The input (source) file may be corrupted.
There is no remedy for this situation.
Can't send after socket shutdown text
No data can be sent because the socket has shut down.
Cannot access file filename
[More]
The More command cannot find the file you specified as an argument.
Check the spelling of the filename and the path of the file. Retry the More command with a corrected file specification.
Cannot access Registry key values.
[Remote Access Service]
The Remote Access Service failed to start because required Registry keys may be missing from the Registry.
Remove and then reinstall the Remote Access Service using the Network option in Control Panel. If after reinstalling the service you continue to see this message, contact technical support.
Cannot access service controller.
[Control Panel]
The service controller is a component that loads and unloads network drivers. Because the Network option cannot access the service controller, you cannot perform the current operation.
Contact technical support.
Cannot access TCPCFG library or it's entry points.
[Remote Access Service]
RAS could not find the TCPCFG.DLL file.
Use the Network option in Control Panel to remove and reinstall the TCP/IP protocol.
Cannot add name to list
[Remote Access Service]
This is an out of memory condition. RASADMIN is not able to add the specified item to a list of names (ports, users, or servers, etc.).
Try closing other applications to allow RASADMIN more memory.
Cannot add the remote computer group name name on LANA number. The error code is the data.
[Remote Access Service]
A computer has the same name as the remote computer group name.
Remove the computer with the duplicate name from the network.
Cannot add the remote computer name computer name on LANA number .The error code is the data.
[Remote Access Service]
Another computer on the network has the same name as the remote computer.
Remove the other computer from the network or rename the remote computer.
Cannot adjust the logon rights and group membership of account account. The startup parameters for the name service may be in an inconsistent state. Error number occurred: text
[Server Manager]
An unexpected error occurred while the system was attempting to assign an account to the Replicator local group.
Consult the event log in Event Viewer for details on this error. Then, if necessary, contact your technical support group.
Cannot allocate memory in the admin support thread for the Remote Access Service.
[Remote Access Service]
A request from the Remote Access admin (RASADMIN.EXE) failed.
Restart your computer. If the problem persists, check your system's configuration, quotas, and resources. There may be problems with your system's memory. For further information, consult your Windows NT documentation.
Cannot allocate memory.
[Remote Access Service]
The system has run out of memory.
Close some applications, and redial.
Cannot allocate memory. Close some applications, and retry.
[Remote Access Service]
A system call to allocate memory failed.
Close some applications to reduce system memory usage and retry the operation that failed.
Cannot carry out the Word Wrap command because there is too much text in the file.
[Notepad]
Because your computer is low on memory, Notepad cannot wrap the text that you have typed.
To free memory, close one or more of the applications that you have running, then try again.
Cannot change Boot.ini file. Operating System and Timeout changes will not be saved.
[Program Manager]
Most likely, you do not have Write permission on the BOOT.INI file.
Change the permissions on this file so that you can write to the file, or ask the system administrator to do so for you. Then try again.
Cannot change Boot.ini file. Operating System and Timeout changes will not be saved.
[Program Manager]
Log on as an administrator and try again.
Cannot change Windows Default.
[Program Manager]
In the Color Schemes list, you attempted to remove the Windows default color scheme. Windows NT does not permit the removal of this scheme.
Choose OK.
Cannot change Windows Default.
[Program Manager]
In the Color Schemes list, you attempted to remove the Windows default color scheme. Windows NT does not permit the removal of this scheme.
Choose OK.
Cannot CHKDSK a network drive.
[Chkdsk]
You cannot use the Chkdsk command with a local drive letter that has been redirected over the network.
If you must run Chkdsk on the drive that is on the network, you will have to use the computer that is local to that drive.
Cannot CHKDSK a SUBSTed or ASSIGNed drive.
[Chkdsk]
A SUBSTed drive is a virtual drive hosted on another volume, and cannot be checked. The host volume must be checked instead. The Chkdsk command does not work on drives formed by the Subst or Assign commands.
Determine the host volume of the SUBSTed drive and run Chkdsk on that volume.
Cannot clear port statistics on server computer name
[Remote Access Service]
The server may be down or you may have too many applications running. A network or system error may have occurred.
At the command prompt, use the net view command to verify that you can see the server. If so, stop some applications running on the server. Also, check the Event Log in Event Viewer for information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot clear port statistics.
[Remote Access Service]
The server may be down or you may have too many applications running. A network or system error may have occurred.
At the command prompt, use the net view command to verify that you can see the server. If so, stop some applications running on the server. Also, use the Event Log in Event Viewer to see information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot close while DDE conversations are in progress. WM_CLOSE ignored.
[Dynamic Data Exchange]
You tried to close the Dynamic Data Exchange (DDE) while an application was using it. Do so would disrupt the application and could cause data corruption.
Try again later.
Cannot complete this function.
[Kernel32]
The function was called in an inappropriate context. For example, the GetSelection() API will return this message if it is called when there is no selection.
Contact the supplier of the running application.
Cannot connect network drive
[File Manager]
The computer sharing this drive might not be running on the network or might already have the maximum number of connections to it. Or, there may be a problem with the hardware or software that connects your computer to the network. Or, you might not be logged on to the network.
If you are able to connect to other network resources, check to make sure the remote computer is running and is able to accept connections. If you are not able to connect to any resources, and you are logged on, check the event log for errors involving network adapter cards and their drivers or protocols, and take the appropriate action on these errors. Then try again.
Cannot connect to OS2 SubSystem
[OS/2 Subsystem]
The Windows NT OS/2 subsystem cannot start up because the OS/2 subsystem client cannot connect to the OS/2 subsystem server. The server may be busy.
This may be a temporary condition. Wait, then retry running the OS/2 application. If you continue to get this message, contact your technical support staff.
Cannot construct accelerators.
[Remote Access Service]
An internal problem has occurred. RAS, Windows NT, or NETUI*.dll might need to be replaced.
Use the Network option in Control Panel to remove and reinstall RAS. If you continue to see this message, try replacing NETUI*.DLL from the distribution media. If you still receive this message, contact technical support.
Cannot construct application.
[Remote Access Service]
An internal problem has occurred. RAS, Windows NT, or NETUI*.dll might need to be replaced.
Use the Network option in Control Panel to remove and reinstall RAS. If you continue to see this message, try replacing NETUI*.DLL from the distribution media. If you still receive this message, contact technical support.
Cannot construct dialog
[Remote Access Service]
This indicates a low memory problem. Depending on which dialog failed to construct, you may not be able to perform the required operation. RAS, Windows NT, or NETUI*.DLL may need to be replaced.
Try closing other Windows applications, or try restarting the system.
Cannot convert file system volumes to filename .
[Convert]
The Convert utility cannot make the specified file system conversion. In this version of Windows NT, two conversions are possible: (1) FAT to NTFS, or (2) HPFS to NTFS.
Verify that the file system you are attempting to convert is either FAT or HPFS.
Cannot CONVERT a network drive.
[Convert]
You cannot use the Convert command on drives that have been redirected over the network.
Run the Convert utility on the computer that is local to the drive you want to convert.
Cannot convert an extended attribute
[Convert]
During a FAT to NTFS file system conversion, the Convert utility was unable to convert an extended attribute.
The FAT partition is still in its original (unconverted) state. Run the Chkdsk command with the /f option and try the conversion again.
Cannot copy file to itself
[Program Manager]
Try again, specifying a different filename to copy the file to.
Cannot copy to filename from filename
[Program Manager]
You attempted to copy a file to itself, and this action is not permitted.
No action is needed.
Cannot copy to filename from filename
[Program Manager]
You attempted to copy a file to itself, and this action is not permitted.
No action is needed.
Cannot copy to Clipboard; close one or more Windows applications and try again.
[Help]
The applications that you have running are making demands upon your system's memory that make it temporarily impossible for Windows NT to access the Clipboard.
Perform the action prescribed in the message.
Cannot create filename file.
[TCP/IP]
Try again, providing a different filename.
Cannot create filename
[Program Manager]
This message occurs when a file cannot be created for the copy operation. For example, you attempted to copy a font from one device to another, and the font file could not be created on the target device.
Choose OK.
Cannot create filename
[Program Manager]
This message occurs when a file cannot be created for the copy operation. For example, you attempted to copy a font from one device to another, and the font file could not be created on the target device.
Choose OK.
Cannot create a file when that file already exists.
[Kernel32]
If you can do it at the user interface, specify a different filename. Otherwise, contact the supplier of the running application.
Cannot create a named pipe instance in the admin support thread for the Remote Access Service.
[Remote Access Service]
Restart your computer. If the problem persists, check your system's configuration, quotas, and resources. There may be problems with your system's memory. For further information, consult your Windows NT documentation.
Cannot create a stable subkey under a volatile parent key.
[Kernel32]
In the Registry, if the parent key of a subtree is volatile then all descendants must be volatile too.
Contact the supplier of the running application.
Cannot create a top-level child window.
[Kernel32]
As part of its user interface, an application has tried to create a child window at an inappropriate level.
Contact the supplier of the running application.
Cannot create a value entry without a title. Please enter a title.
[Registry Editor]
You attempted to create a value entry in Registry Editor, but did not assign a title to it.
Assign the entry a title, then choose OK.
Cannot create an instance thread in the admin support thread for the Remote Access Service.
[Remote Access Service]
A request from the Remote Access admin (RASADMIN.EXE) failed.
Restart your computer. If the problem persists, check your system's configuration, quotas, and resources. There may be problems with your system's memory. For further information, consult your Windows NT documentation.
Cannot create another system semaphore.
[Kernel32]
All the system semaphore slots have been used. Another system semaphore cannot be created until one has been freed.
Try again later.
Cannot create another thread.
[Kernel32]
The thread table for the process is full; another thread cannot be added.
Remove some idle threads and try again, or use a different process.
Cannot create bookmark file.
[Help]
You have attempted to create a bookmark in a Help file to which you do not have write access.
Remove the read-only protection from the file, then try again.
Cannot create bookmark; remove the Read Only attribute for .BMK files.
[Help]
You attempted to create a bookmark when the .BMK file in your Windows NT directory is read-only protected.
In your Windows NT root directory in File Manager, use the Properties option to remove read-only protection, particularly from the WINHELP.BMK file.
Cannot Create CONOUT
[OS/2 Subsystem]
The Windows NT OS/2 subsystem cannot start up because standard output cannot be redirected to a file. The disk to which you are trying to redirect the output may be full, or you may not have write access to the disk.
Run the OS/2 application again, specifying a different destination for standard output. If you continue to get this message, contact your technical support staff.
Cannot create LMHOSTS file.
[Control Panel]
Your computer does not have sufficient disk space for the LMHOSTS file.
Verify that your computer has enough disk space. If so, contact your system administrator because there may be other problems with your system.
Cannot create new phone book.
[Remote Access Service]
CreateFile failed. The system may be running out of memory.
Check for an existing phone book file with protected attributes using the Properties from the File menu in File Manager. Check available disk space. Try closing other applications and services that are not in use. You might also want to remove any unneeded files and applications from your disk.
Cannot create or modify annotations; please exit WinHelp and remove the Read Only attribute for filename .
[Help]
Because the permissions on your annotation file do not allow it to be written to, no annotations can be added to the file.
Exit WinHelp and remove the Read Only attribute for the annotation file. Then try again.
Cannot create specified file. Make sure that: You have enough disk space. The file is not read-only. The filename is valid.
[Terminal]
Terminal is presently unable to create a temporary file that must be created for a file to be saved.
Follow the user action specified in the message.
Cannot create the filename file. Make sure that the path and filename are correct.
[Notepad]
In the Open dialog box, or from the command prompt, you specified the name of a file or a command path that does not exist.
In the Open dialog box, browse through the directories until you locate the file for which you are searching. Or, at the command prompt, specify a valid filename.
Cannot create the elementary file system structures.
[Convert]
During a FAT to NTFS file system conversion, the Convert utility could not create the elementary NTFS file system structures on the target volume.
Delete unnecessary files and retry the conversion. If this message reappears, the volume may not be suitable for conversion.
Cannot delete existing annotation.
[Help]
You attempted to delete an annotation when the .ANN file is either read-only or is saved to a network connection.
If you are sure you want to delete the annotation, copy the appropriate .ANN file to your hard disk, then delete it. Or, if the file is read-only, use the Properties option in File Manager to remove this protection, then delete the file.
Cannot delete system group
[User Manager]
When you install Windows NT, certain built-in user groups already appear in your User Manager window, and you cannot delete these groups.
Select OK.
Cannot delete the remote computer group name name from LANA number .The error code is the data.
[Remote Access Service]
An internal system error occurred.
Contact technical support.
Cannot delete the remote computer name computer name from LANA number .The error code is the data.
[Remote Access Service]
An internal system error occurred.
Contact technical support.
Cannot destroy object created by another thread.
[Kernel32]
One part of an application, as part of its user interface, has tried to delete a window owned by another part of the application.
Contact the supplier of the running application.
Cannot detect carrier.
[Remote Access Service]
A modem did not pick up the phone. Many modems return this error if the remote modem does not pick up the phone.
Please check the number and dial again. To automate redialing, set the Redial Settings option on the Phone Book's Options menu. For more information, see "Redialing" in the Remote Access Service online Help.
Cannot determine file system of drive drive letter .
[Utilities]
The utility cannot determine the file system (FAT, HPFS, or NTFS) for the volume, and cannot proceed.
Make sure you have administrative privilege, then try the operation again.
Cannot determine location of system directory.
[Convert]
The Convert utility needs to use files that it assumes are in the system directory, but it cannot find the system directory.
Make sure you have the privileges associated with the administrator group and that you have access to the system directory.
Cannot disconnect user name from server computer name
[Remote Access Service]
An error occurred while trying to disconnect the specified user from the Remote Access server.
Check the Event Log in Event Viewer in the Administrative Tools group for other errors related to this one.
Cannot disconnect phone book entry.
[Remote Access Service]
RasHangUp failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot DISKCOPY to or from a network drive
[Disk Copy]
Diskcopy can be used only with local drives.
Verify that your are using the Diskcopy command on a local drive.
Cannot dismount the drive.
[Utilities]
No action is needed but you may have to restart the computer to access the drive.
Cannot display cursor blinking rate; to display rate, close one or more Windows applications and try again
[Program Manager]
There is not enough free memory to display the cursor blinking rate.
Cannot display cursor blinking rate; to display rate, close one or more Windows applications and try again
[Program Manager]
You are low on system memory.
Follow the action specified in the message.
Cannot display data.
[Remote Access Service]
Usually this message indicates a character set conversion problem. There is an internal problem with RAS.
Use the Network option in Control panel to remove and reinstall RAS.
Cannot divide by zero
[Calculator]
You have attempted to divide a number by zero.
Choose the C or CE button (or press ESC) to clear the calculation and start again. If you are using the recall memory as a divisor, verify that the value in memory is non-zero by pressing MR.
Cannot enumerate a non-container.
[Kernel32]
Windows NT organizes a network logically as a hierarchy. An application program can request a list of all resources below a specified network resource in the hierarchy, but in this case an application specified a network resource at the bottom of the hierarchy.
If you have a user interface, retry the request with a different network resource specified (for example, the resource at the root of the tree). Otherwise, contact the supplier of the running application.
Cannot enumerate Adapters in Registry
[Control Panel]
The Network option is having difficulty accessing the node in the Registry that contains information on adapters.
Contact technical support.
Cannot enumerate ports on server computer name
[Remote Access Service]
The server may be down or you may have too many applications running. A network or system error may have occurred.
At the command prompt, use the net view command to verify that you can see the server. If so, stop some applications running on the server. Also, use the Event Log in Event Viewer to see information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot enumerate Products in Registry
[Control Panel]
The Network option is having difficulty accessing the node in the Registry that contains information on products.
Contact technical support.
Cannot enumerate Registry key values.
[Remote Access Service]
The Remote Access Service failed to start because required Registry keys may be missing from the Registry.
Use the Network option in Control Panel to remove and reinstall the Remote Access Service.
Cannot enumerate Remote Access ports.
[Remote Access Service]
The server may be down or you may have too many applications running. A network or system error may have occurred.
At the command prompt, use the net view command to verify that you can see the server. If so, stop some applications running on the server. Also, use the Event Log in Event Viewer to see information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot enumerate servers on focus domain
[Remote Access Service]
The focus domain you specified either does not exist or no domain controllers exist in the domain.
Use the Remote Access Admin option in the Remote Access group to change the focus to a valid domain. From the Server menu, select Domain or Server. Then type the domain or server name in the Domain box.
Cannot enumerate Services in Registry
[Control Panel]
The Network option is having difficulty accessing the node in the Registry that contains information on services.
Contact technical support.
Cannot enumerate the Remote Access Connection Manager ports.
[Remote Access Service]
Your adapter card and its driver may be configured incorrectly.
Make sure the multiport adapter card and software have been correctly installed and configured. If so, remove and reinstall the Remote Access Service using the Network option in Control Panel.
Cannot enumerate users on focus domain - name
[Remote Access Service]
Verify that the Remote Access Server that contains user accounts is accessible.
Cannot enumerate users on focus domain or server
[Remote Access Service]
There is a problem with the server that contains user accounts. Until the problem is corrected, you will be unable to view the Remote Access permissions of user accounts or modify them.
Verify that the server with user accounts is working properly and is accessible.
Cannot enumerate users on focus server - name
[Remote Access Service]
.
Verify that the Remote Access Server that contains user accounts is accessible.
Cannot execute second macro while first is in process.
[Help]
This error is from the Macro Language Editor for online help, and should not appear while using the Help file. Report this error to the provider of the Help file.
Cannot find filename.
[Cardfile]
In the Open File dialog box, you directed Cardfile to find a file that does not exist on the currently selected directory.
Make sure that both the path and filename are correct.
Cannot find a user or group account with name name on the indicated domain(s).
[Network]
Either the name was mistyped, or it has been removed from the domain(s), or it has not yet been added to the domain(s). In some cases the account has been added to the domain but has not yet been replicated to the Backup Domain Controller that this computer is getting information from.
Wait and try again, making sure the name is typed correctly. You might want to ask the network administrator to add the name.
Cannot find any icons in this file
[Program Manager]
In the Change Icon dialog box, you specified a file in which no icons exist.
Choose OK, then specify another file.
Cannot find file filename (or one of its components); check to ensure the path and filename are correct and that all required libraries are available.
[Program Manager]
In Program Manager, you selected an icon that is not attached to an executable program file. Or, using the Run option on the File menu, you specified the name of a file that does not designate an executable program.
Select the icon, and then choose the Properties option on the File menu. When the Program Item Properties dialog box appears, the name of the selected program's executable file appears in the Command Line option box. Ensure that the file listed here is the executable file for the selected program.
Cannot find file filename (or one of its components); check to ensure the path and filename are correct and that all required libraries are available.
[Task Manager]
The application cannot continue without information contained in the indicated file.
If the path and filename are correct, make sure that none of the executable (.EXE) or library (.DLL) files are missing or corrupt. You might need to restore files from a backup copy or reinstall the software.
Cannot find key.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. If you are using a modem that is not supported by Remote Access, switch to a supported modem. For more information about modem script files, see "Modem Script File" in the Remote Access Service online Help. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot find Primary for computer name. Continuing with the promotion may result in errors when computer name's old Primary comes back on line. Do you want to continue with the promotion?
[Server Manager]
If you choose to promote a computer to domain controller, the system usually automatically demotes the previous domain controller to server status. The previous domain controller is currently not available. When it comes back online, it will not run the Netlogon service, and it will not participate in authentication of user logons.
Choose Yes. Then, when the previous domain controller comes back online, demote it manually.
Cannot find printer or printer driver.
[Help]
Either your computer is not connected physically to a printer, or the printer has not been properly configured on your system.
Check your physical connections. Or use Printers in Control Panel to configure your printer.
Cannot find the filename file. Do you want to create a new file?
[Notepad]
In Notepad, you attempted to open a file that does not exist in the location that you have specified in the Open dialog box.
If you want to create the file, select Yes. If not, select No. If you wish to return to the currently opened Notepad file, select Cancel.
Cannot find the Control Panel components (files with .CPL extension). Verify that they are installed in your Windows NT SYSTEM32 directory.
[Control Panel]
To run Control Panel, files with a .CPL extension must appear in your Windows NT SYSTEM32 directory.
Do a search in File Manager for .CPL files, then drag and drop these files into your Windows NT SYSTEM32 directory.
Cannot find the phone book entry.
[Remote Access Service]
Remote Access has located the Phone Book but cannot find the specified entry. This error should not occur unless you are writing to Remote Access APIs, and have specified an incorrect entry name. The Remote Access Service uses the file RASPHONE.PBK, located in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot find the Primary DC for name. You may administer this domain, but certain domain-wide operations will be disabled.
[Server Manager]
The domain controller for the domain of focus cannot be found, possibly because the computer that serves as domain controller is not started.
If the administrative actions you want to perform must apply to all of the workstations in the selected domain, and the action is disabled, wait until the domain controller of the selected domain comes back online, then try again.
Cannot find the settings file filename .Insert the disk with the file in drive A.
[Terminal]
You attempted to call a file from the command line, the file could not be located.
Follow the user action specified in the message.
Cannot find the specified drive or directory. Make sure the path is correct.
[Terminal]
You have specified a directory that does not exist in the path that you have specified.
Specify the correct drive and directory, then try again.
Cannot find the specified file. Make sure the path and filename are correct.
[Terminal]
You attempted to open a file and have specified a path that does not lead to the file.
Make sure that the path and filename are correct. Or do a search for the file in File Manager.
Cannot find window class.
[Kernel32]
An application tried to use a window class that was not an application-specific class registered with the system or one of the predefined control classes (such as BUTTON, LISTBOX, SCROLLBAR, etc.).
Contact the supplier of the running application.
Cannot format a network drive.
[Format]
You specified a network drive in the Format command.
You cannot format drives that are redirected over the network.
Cannot format a RAM DISK drive.
[Format]
You specified a RAM disk in a Format command. You cannot format a RAM disk.
Cannot format an ASSIGNed or SUBSTed drive.
[Format]
ASSIGNed or SUBSTed drives aren't really disks, they're just part of other disks. Also, the Format command ignores drive reassignments.
No action is needed.
Cannot format. This media is write protected.
[Format]
You cannot format a write-protected disk.
Either remove the write-protection or use another disk.
Cannot get account information for user user name
[Remote Access Service]
Verify that the Remote Access Server that contains user accounts is accessible.
Cannot get information from server computer name
[Remote Access Service]
The server may be down or you may have too many applications running. A network or system error may have occurred.
At the command prompt, use the Net View command to verify that you can see the server. If so, stop some applications running on the server. Also, check the Event Log in Event Viewer for information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot get list of Adapters
[Control Panel]
The Network option is having difficulty accessing the node in the Registry that contains the list of adapters. Therefore, you cannot complete the current operation.
Contact technical support.
Cannot get list of Products
[Control Panel]
The Network option is having difficulty accessing the node in the Registry that contains the list of products. Therefore, you cannot complete the current operation.
Contact technical support.
Cannot get port information from server computer name
[Remote Access Service]
The server may be down or you may have too many applications running. A network or system error may have occurred.
At the command prompt, use the net view command to verify that you can see the server. If so, stop some applications running on the server. Also, use the Event Log in Event Viewer to see information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot get port information.
[Remote Access Service]
The server may be down or you may have too many applications running. A network or system error may have occurred.
At the command prompt, use the net view command to verify that you can see the server. If so, stop some applications running on the server. Also, use the Event Log in Event Viewer to see information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot get port statistics.
[Remote Access Service]
RAS Manager call RasPortGetStatistics failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot get port status. Reconfigure Remote Access for the correct port.
[Remote Access Service]
The specified port is not configured to use RAS. This situation might also occur if RAS values in the Registry have been changed to invalid values.
Use the Network option in Control Panel to reconfigure RAS. In the Installed Network Software box select Remote Access Service. Then choose Configure to configure a port for RAS to use. If the Registry has been corrupted, remove and reinstall RAS.
Cannot get send/receive buffer.
[Remote Access Service]
This message indicates an internal problem with RAS Phone or RAS Manager.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot get status information for a connection.
[Remote Access Service]
RAS API call RasGetConnectStatus failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot get status information for a port.
[Remote Access Service]
RAS Manager call RasGetInfo failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot get timer. Close Mail and/or Fax (if they are running), and retry.
[Remote Access Service]
The SetTimer Win32 API failed. This indicates a timer, which is a finite system resource, was not available.
Close other running applications that might be using up timers.
Cannot hang up the Remote Access connection.
[Remote Access Service]
RAS API call RasHangUp failed.
Wait a few minutes and then try disconnect again. If waiting is unsuccessful, try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot initialize IP address control.
[Remote Access Service]
An internal problem has occurred. RAS, Windows NT, or NETUI*.dll might need to be replaced.
Use the Network option in Control Panel to remove and reinstall RAS. If you continue to see this message, try replacing NETUI*.DLL from the distribution media. If you still receive this message, contact technical support.
Cannot load a string.
[Remote Access Service]
This error should not occur under normal circumstances.
Restart your computer to make sure that all recent configuration changes have taken effect. If the error persists, consult the Windows NT event log for detailed warnings or errors.
Cannot load extension name .Error number
[Server Manager]
The functionality supplied by the specified extension will not be available.
Make sure the .DLL file for the extension is present. Restore it from a backup copy if necessary.
Cannot load extension name .Error number : text
[Server Manager]
The functionality supplied by the specified extension will not be available.
Make sure the .DLL file for the extension is present. Restore it from a backup copy if necessary.
Cannot load function address of "name " from "filename " DLL
[Dynamic Data Exchange]
The indicated function will not be available because the application will not be able to find the instructions to it. Commands using this function will not work.
Cannot load phone book or RAS Manager data.
[Remote Access Service]
RAS Manager or phone book file operation failed during initial data loading.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot load RASMAN functions. Remove and reinstall Remote Access.
[Remote Access Service]
Use the Network option in Control Panel to remove and then reinstall RAS. In the Installed Network Software box select Remote Access Service and then choose Remove. Restart your computer. Select Network in Control Panel and choose Add Software to reinstall RAS.
Cannot load Shell32 library.
[Remote Access Service]
SHELL32.DLL file was not found.
No action is needed.
Cannot load the filename driver. The driver file may be missing. Try installing the driver again, or contact your system administrator.
[Drivers (CP)]
A device cannot function properly without a driver, and the specified driver file is missing. It should appear in your SYSTEM32 directory.
Locate the file in File Manager, then move it to your SYSTEM32 directory.
Cannot load the About Box.
[Remote Access Service]
The standard SHELL32.DLL ShellAbout call failed. The About box contains copy written information about the product and version numbers.
No action is needed.
Cannot load the NetBIOS gateway DLL component.
[Remote Access Service]
RASGTWY.DLL is missing or corrupted.
Either copy RASGTWY.DLL from your installation disks or reinstall the Remote Access Service. Use Network in Control Panel to remove and then reinstall the Remote Access Service.
Cannot load the phone book file.
[Remote Access Service]
The Remote Access Service uses the RASPHONE.PBK file in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Make sure the file is on this path, and restart Remote Access.
Cannot load Windows Help application.
[Backup]
Backup cannot display online Help. This problem can occur due to a lack of system resources or because the file containing Help for backup has been deleted from your drive.
To increase system resources, close one or more of the applications that you have running. To ensure that the file is on your disk, exit or minimize Backup, open File Manager, then do a search for BACKUP.HLP.
Cannot locate name service for protocol name in the TCP/IP network services database. The service could not be started.
[Netevent]
The services file is corrupted or does not exist.
Verify that the services file is present and in the proper location.
Cannot locate or create an NTFS index
[Convert]
During a FAT to NTFS file system conversion, the Convert utility was unable to create an NTFS root index.
The FAT partition is still in its original (unconverted) state. Delete some files from the partition and run the Chkdsk utility with the /r option. Then retry the conversion.
Cannot lock current drive.
[Utilities]
The utility cannot gain exclusive access to a volume that is the current drive for any process.
Check the current drive for all console windows and applications and try again.
Cannot lock the drive. The volume is still in use.
[Utilities]
The file system utility requires exclusive use of a volume (for example, to format it). However, the utility cannot lock the volume for your exclusive use right now. Somebody else may be using it.
Shut down other applications and console windows that are using the drive, and try again.
Cannot log on. User is currently logged on and argument TRYUSER is set to NO.
[Network]
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The computer cannot update its copies of the replicated files while a user is logged on and the TRYUSER option is set to NO.
No action is needed. The computer will update the files when no user is logged on. To have the local computer update files while users are logged on, change the value of the TRYUSER entry in the [replicator] section of the configuration file to YES.
Cannot multiplex module name.The service could not be started.
[Netevent]
The specified module was installed incorrectly.
Remove the TCP/IP protocol and then reinstall it using the Network option in Control Panel.
Cannot open filename .
[Aclconv]
The Aclconv utility was unable to open the specified file. It may have been attempting to query an existing data file, set the file pointer to the top of an existing log file, or create a new log file.
Check to make sure that the file names are valid in the command line, and that the data file (if specified) and log file (if specified) exist and are accessible.
Cannot open an anonymous level security token.
[Kernel32]
An attempt was made to open a client's anonymous-level security token. A token must have an impersonation level of at least "Identification" to be opened.
Contact the supplier of the running application. A general workaround, if the application interface allows it, is to avoid trying to open the anonymous token, or to specify a higher level of impersonation for the client program.
Cannot open Clipboard.
[Calculator]
You tried to paste from the Clipboard, but another application has the Clipboard locked open. Most likely, this indicates a bug in the application that has the Clipboard locked open.
Choose OK, then try again later. Or attempt to close the application that is using the Clipboard.
Cannot open file. Start the application used to create this file, and open it from there.
[Program Manager]
A system error occurred while you were querying for a file association.
Perform the action specified in the message.
Cannot open Help file.
[Help]
Either the help file is corrupt, or there is not enough free memory to open the file, or you do not have sufficient permissions on either the file or a directory that it is in to read the file.
If this message was accompanied by a message citing insufficient memory, close some applications and try again. Otherwise, make sure you have Read permission on every directory leading to the .HLP file, and to the file itself, and try again. If you still get this message, restore the file from a backup copy and try again.
Cannot open program group group
[Program Manager]
You have attempted to delete from Program Manager a group that has been damaged or deleted from the Registry.
There is no user action for this situation.
Cannot open program group group. Do you want the Program Manager to still try to load it in future ?
[Program Manager]
One of the two following circumstances exist: (1) you lack the permission to access the REGEDT32 key that contains the user profile; or (2) the group was corrupted and cannot be read from the Registry.
If you want Program Manager to load the specified group in the future, choose Yes. If not, choose No.
Cannot open SYSTEM Environment section in Registry. Possible registry corruption.
[Program Manager]
Check the SYSTEM Environment section in the Registry for this computer. Also, make sure the security settings on this Registry key allow you to read it. If you still get this error, restart the computer, and press the spacebar immediately after selecting Windows NT at the Boot Loader prompt. Then choose Last Known Good.
Cannot open the name file. Make sure a disk is in the drive you specified.
[Notepad]
You designated an empty drive for the location of a file.
Either insert the disk that contains the file into the appropriate disk drive, or select a different disk drive.
Cannot open the filename file. Please make sure that you specified the correct path for the LMHOSTS file.
[TCP/IP]
The LMHOSTS file is a local text file that maps IP addresses to the NetBIOS names of computer outside of the local subnet. Without this file, you may be unable to communicate with these computers.
Make sure that you have specified the correct path and filename for this file.
Cannot open the LMHOSTS file. Please make sure that you specified the correct path for the LMHOSTS file.
[Control Panel]
The LMHOSTS file is a local text file that maps IP addresses to the NetBIOS names of computer outside of the local subnet. Without this file, you may be unable to communicate with these computers.
Make sure that you have specified the correct path to this file.
Cannot open the MIDIMAP.CFG file. Make sure the file is available.
[MIDI Mapper (Control Panel)]
The MIDIMAP.CFG file, which configures your MIDI Mapper options, must be in your Windows NT SYSTEM32 directory before Windows NT can initialize the MIDI Mapper dialog.
Exit or minimize Control Panel, and open File Manager. Search for the file, then move it into your SYSTEM32 directory.
Cannot open the phone book file.
[Remote Access Service]
The Remote Access Service uses the RASPHONE.PBK file in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Make sure the file is on this path, and restart Remote Access.
Cannot open the RasServer parameters Registry key.
[Remote Access Service]
The specified Registry key may be missing from the Registry.
Remove and then reinstall the Remote Access Service using the Network option in Control Panel. If after reinstalling the service you continue to see this message, contact technical support.
Cannot open the settings file because it is invalid. Specify the settings you want to use, and then save them to a new file.
[Terminal]
The settings file that you want to open is corrupted.
Follow the user action specified in the message.
Cannot open USER Environment section in Registry. Possible registry corruption.
[Program Manager]
The HKEY_CURRENT_USER\\Environment section of REGEDT32 may be corrupted.
See your system administrator. Or contact technical support, and report the content of this message.
Cannot open USER Environment section in Registry. Possible registry corruption.
[Program Manager]
The HKEY_CURRENT_USER\\Environment section of REGEDT32 may be corrupt.
Check the USER Environment section in the Registry for this computer. Also, make sure the security settings on this Registry key allow you to read it. If you still get this error, restart the computer, and press the spacebar immediately after selecting Windows NT at the Boot Loader prompt. Then choose Last Known Good.
Cannot open volume for direct access.
[Utilities]
Make sure the floppy disk is in the drive and the drive is ready.
Cannot operate on file. Make sure the file or disk is not damaged or write-protected.
[Write]
You have attempted an operation on a file that is damaged or that is write-protected. This message can also appear if you attempt to open or save changes to a file that is saved to a network server to which you are no longer connected.
Remove the write-protection. Or, if the file is saved to a network connection, reestablish the network connection, then try again to operate on the file.
Cannot paste from Clipboard. Please verify that the Clipboard contains text.
[Cardfile]
If you have made an error in copying a picture to the Clipboard, the Clipboard may not contain the picture that you are attempting to paste into a file.
Double-click the Clipbook Viewer icon. Select Clipboard in the Window menu, and the object appears in the Clipbook Viewer window. If the object does not appear, return to the source file, and copy the object again.
Cannot perform a cyclic copy
[Xcopy]
When using the Xcopy command, followed by the /s switch, you cannot copy to any subdirectories that are a subset of the directory you are copying from.
Specify a destination that is not a subdirectory of the source directory.
Cannot perform this operation on built-in accounts.
[Kernel32]
An operation has been attempted on a built-in account which is incompatible with the nature of built-in accounts. For example, built-in accounts cannot be renamed or deleted.
Contact the supplier of the running application.
Cannot perform this operation on this built-in special group.
[Kernel32]
Contact the supplier of the running application.
Cannot plumb unknown driver/module name.The service could not be started.
[Netevent]
The driver or module was installed incorrectly.
Remove the TCP/IP protocol and then reinstall it using the Network option in Control Panel.
Cannot print. Be sure that the printer is connected and set up properly.
[Cardfile]
Choose the Print Setup command from the File menu to verify that the default printer is active. Or choose Print Manager from the program group Main in Program Manager to verify current printer status.
Cannot print; run Control Panel to install and set up printers.
[Help]
Nothing can be printed because your system is not aware of any printers.
Choose Printers from the Control Panel to set up at least one printer. For more information choose Help in the Print Manager dialog box.
Cannot process a message from a window that is not a multiple document interface (MDI) window.
[Kernel32]
An application, as part of its user interface, has operated on a window that is part of an MDI window set as if it were an independent window.
Contact the supplier of the running application.
Cannot read boot sector.
[Utilities]
A critical sector near the beginning of the volume is unreadable. Back up files from the drive and replace the disk.
Cannot read file allocation table
[Recover-FAT/HPFS]
Use the Chkdsk command with the /f switch to correct the problem. If you still get this message, you may have to reformat the disk. After that, if you are using a hard disk and you still get this message, contact the hardware vendor.
Cannot read information from the registry.
[Remote Access Service]
Either the Registry is corrupted or another application is using the Registry.
Try closing other running applications.
Cannot read the device name from the media .INI file.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot read the device type from the media .INI file.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot read the maximum carrier BPS rate from the media .INI file.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot read the maximum connection BPS rate from the media .INI file.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot read the media .INI file.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot read the section name from the media .INI file.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot read the specified file. Make sure the path and filename are correct.
[Terminal]
You attempted to open a file that does not exist in the path that you have specified.
Click the OK button to return to the Open dialog box. Then, if necessary, type "*.TRM" in the File Name box, then open the individual directories in the Directories box until the Terminal file that you are looking for appears in the File Name box.
Cannot read the usage from the media .INI file.
[Remote Access Service]
One of the Remote Access configuration files probably contains invalid information.
The easiest way to resolve this problem is to reinstall Remote Access. Use the Network option in Control Panel to remove and reinstall RAS. If you are using a modem that is not supported by Remote Access, switch to a supported modem, or see "Modem Script File" in the Remote Access Service online Help for information about modifying the modem script file for your modem. The Remote Access script files (PAD.INF, MODEM.INF, and SWITCH.INF) are in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot read/save UPS information in the registry.
[Control Panel]
UPS configuration information cannot be accessed or written to the Registry.
Make sure that you have access to the Registry key that contains UPS's configuration information.
Cannot receive buffer from device.
[Remote Access Service]
RAS Manager call RasPortReceive failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot receive initial frame on port address .The user has been disconnected.
[Remote Access Service]
There could be a problem with the modem connection.
Make sure you're using a supported modem. If so, try using a lower baud rate. If you continue to see this message, contact technical support.
Cannot RECOVER a network drive
[Recover-FAT/HPFS]
You cannot recover files on drives that are redirected over a network, or files that are located on a network drive.
Cannot RECOVER an ASSIGNed or SUBSTed drive
[Utilities]
The Recover command does not work on a drive formed by the Assign, Join, or Subst command.
Cannot register help file.
[Remote Access Service]
An internal problem has occurred. RAS, Windows NT, or NETUI*.dll might need to be replaced.
Use the Network option in Control Panel to remove and reinstall RAS. If you continue to see this message, try replacing NETUI*.DLL from the distribution media. If you still receive this message, contact technical support.
Cannot register your computer on the remote network.
[Remote Access Service]
The Remote Access server was unable to register your computer's name on the network.
Contact your system administrator.
Cannot relocate existing file system structures
[Convert]
During a FAT to NTFS file system conversion, the Convert utility was unable to find contiguous space on the volume for the NTFS structures that have to be at a fixed location on the disk.
Delete unnecessary files and retry the conversion. If this message reappears, the volume may not be suitable for conversion.
Cannot remove name
[Program Manager]
In the Color Schemes scrolling list in the Control Panel's Color option box, you have attempted to remove the Windows default color scheme. Windows NT does not permit the removal of this option.
Choose OK.
Cannot remove name
[Program Manager]
You have attempted to remove the Windows default color scheme. Windows NT does not permit the removal of this option.
Choose OK.
Cannot remove phone book entry.
[Remote Access Service]
There may be a problem with the phone book file attributes or the file is locked.
If you can, determine why the file cannot be written to. Try closing other running applications.
Cannot rename to a different directory or disk. Use the File Move command instead.
[File Manager]
Using the Rename command on the File menu, you included the name of another drive in the new name that you want to assign to your directory or file.
To perform this operation, you must use the Move command.
Cannot request exclusive semaphores at interrupt time.
[Kernel32]
Exclusive system semaphores are owned by a task. The system checks to make sure that only the owner modifies the semaphore. It is impossible to determine the requester at interrupt time, so exclusive semaphores may not be modified then.
End your requested operation, wait awhile, and retry. If you still get this message, contact the supplier of the running application.
Cannot reroute printer output to serial device name .
[Mode]
You may not have sufficient privilege to make this change that you have requested with the Mode command.
Change your privilege level and retry the command. You may have to contact your system administrator in order to change your privilege level.
Cannot reset the network adapter for LANA number. The error code is the data.
[Remote Access Service]
The Remote Access Service or other network software is configured incorrectly.
Use the Network option in Control Panel to reconfigure the Remote Access Service by removing and then reinstalling it. If the problem persists, use Network to reconfigure other network software. Otherwise, contact technical support.
Cannot retrieve current system uppercase table. CHKDSK aborted.
[Chkdsk-NTFS]
The uppercase table is used for Unicode translation.
Contact the disk hardware vendor.
Cannot retrieve data from Windows.
[Remote Access Service]
There is an internal problem with RAS.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot retrieve protocol information.
[Remote Access Service]
RAS Manager call RasGetProtocolInfo failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot retrieve the security descriptor for this printer.
[Print Manager]
You cannot get security information from this printer because you do not have the necessary access privileges.
Ask the administrator to give you permission to connect to this printer. Or, if you are the administrator, take ownership of this printer.
Cannot run application in Windows NT mode.
[Kernel32]
The specified file or program is not compatible with Windows NT.
If the specified application is an MS-DOS program, switch to an MS-DOS session and retry the command. Otherwise, reinstall the application and retry the command. If you get this message again, contact the supplier of the application program.
Cannot save changes to phone book.
[Remote Access Service]
There may be a problem with the phone book file attributes or the file is locked. The server may be running out of disk space.
If you can, determine if the problem with the file is its attributes, or its use by another application or disk space. Try closing other running applications and services. Also use File Manager to check available disk space and file attributes.
Cannot save file on a different disk in the same drive. Insert the disk that originally contained the file into the drive or change drives, and then save the file.
[Cardfile]
After accessing a file from one floppy disk, you removed the disk, then attempted to save the original file on another floppy disk.
Follow the user action specified in the message.
Cannot save new Environment variables in Registry. Possible registry corruption.
[Program Manager]
The HKEY_CURRENT_USER\\ Environment section of REGEDT32 may be corrupted.
See your system administrator. Or contact technical support.
Cannot save new Environment variables in Registry. Possible registry corruption.
[Program Manager]
The HKEY_CURRENT_USER\\ Environment section of REGEDT32 may be corrupted.
Check the SYSTEM Environment and USER Environment sections in the Registry for this computer. Also, make sure the security settings on these Registry keys allow you to read them. If you still get this error, restart the computer, and press the spacebar immediately after selecting Windows NT at the Boot Loader prompt. Then choose Last Known Good.
Cannot save new settings
[Program Manager]
The system is unable to save the settings that you have made in the International dialog box.
Exit and restart the application, then try again.
Cannot save new settings
[Program Manager]
The color settings you selected could not be written to the WIN.INI file.
Make sure the permissions on the USER Environment keys allow you Write access and try again
Cannot save program group ' group ' because of insufficient memory.
[Program Manager]
Close some applications and try again.
Cannot send buffer to device.
[Remote Access Service]
RAS Manager call RasPortSend failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot send message to user user name, who is connected to server name from computer computer name
[Remote Access Service]
The messenger service may not be started on the client. Otherwise, a network or system error occurred.
Check the Event Log in Event Viewer for information about related errors. Event Viewer is found in the Administrative Tools group.
Cannot set account information for user user name
[Remote Access Service]
The specified user will be unable to use the Remote Access Service to connect to the network. Also, you cannot revoke the specified user's permissions.
Verify that the Remote Access Server that contains user accounts is accessible.
Cannot set non-local hook without a module handle.
[Kernel32]
An application, as part of its user interface, has tried to install a procedure to monitor system events throughout the application without supplying all the information about that procedure.
Contact the supplier of the running application.
Cannot set port information.
[Remote Access Service]
The Remote Access Phone Book file and the current Remote Access configuration are probably inconsistent.
If you have changed your communications equipment (such as your serial port or modem), be sure to reconfigure Remote Access. Use the Network option in Control Panel to reconfigure Remote Access. If the error persists, remove and recreate the affected Phone Book entry or, reinstall the Remote Access Service. The Remote Access Phone Book (RASPHONE.PBK) is in the SYSTEM32\RAS subdirectory of your Windows NT directory.
Cannot set stop time before start time.
[Performance Monitor]
In the Time dialog, you attempted to select a bookmark as a start time, but its time mark is later than the current stop time. Or you attempted to select a bookmark as a stop time, and the stop time is earlier than your current start time.
Ensure that your start time precedes your stop time.
Cannot set the startup parameters for the name service. Error number occurred: text
[Server Manager]
An unexpected error occurred when the system tried to configure the startup parameters for the specified service.
Consult the event log in Event Viewer for details on the error. Then, if necessary, contact your technical support group.
Cannot show or remove the window in the way specified.
[Kernel32]
An application, as part of its user interface, has tried to change the way a window is displayed. This was done in an inappropriate way, given the set of windows available to it. For example, the application may have tried to hide a window and activate another window, but there was no other window to activate.
Contact the supplier of the running application.
Cannot start a new logon session with an ID that is already in use.
[Kernel32]
Contact the supplier of the running application.
Cannot start disconnect monitor.
[Remote Access Service]
There is an internal problem with RAS.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot start more than one copy of the specified program.
[Program Manager] [Task Manager]
You already have one copy of the specified program running, and you have attempted to open another.
Choose OK, then select the copy of this program that you already have running.
Cannot start RAS Manager.
[Remote Access Service]
RAS Manager call RasInitialize failed.
Try stopping and restarting RAS using the Services option in Control Panel. If this does not solve the problem, try restarting your computer. And finally, use the Network option in Control Panel to remove and reinstall RAS.
Cannot start ShellAbout dialog.
[Remote Access Service]
SHELL32.DLL standard About box call failed.
No action is needed.
Cannot stop printer rerouting at this time.
[Mode]
You cannot use the Mode command to end the rerouting the LPTn: device at this time. It may be busy.
Try the command again at a later time.
Cannot transfer multiple files. Wait until one file has been transferred before transferring another file
[Terminal]
You attempted to send a file while another file is in the process of being transferred. Terminal does not support this function.
Follow the user action specified in the message.
Cannot update the alert list on computer name .
[Server Manager]
You tried to update the Alerts list on a computer that does not support remote alert list updating. Alert lists on LAN Manager servers running versions of LAN Manager earlier than 2.1 cannot be updated remotely
Go to the computer for which you want to update the Alerts list and update it there. You might want to use Windows NT on that computer.
Cannot use 'all' as the device name with the specified command.
Try again, specifying a device by name.
Cannot verify the update setting for the linked object. Delete the card, and then create the link again.
[Cardfile]
When you link an object to a Cardfile file, you have the option to update the object either manually or automatically. Cardfile cannot determine which of these settings you have chosen.
To recreate the link, open the application in which the object was created, and copy the object, using the Copy option on the Edit menu. Then return to Cardfile, and in the Edit menu, select Paste Link.
Cannot write annotations; delete one or more files from the disk.
[Help]
You are low on disk space, and therefore cannot save annotations.
Perform the action prescribed in the message.
Cannot write boot sector.
[Utilities]
A critical sector near the beginning of the volume is unwriteable. Back up files from the drive and replace the disk.
Cannot write file allocation table
[Recover-FAT/HPFS]
Use the Chkdsk command with the /f switch to identify the problem. If you still get this message, you may have to reformat the disk. If you continue to get this message with a hard disk, contact the hardware vendor.
Cannot write information to the registry.
[Remote Access Service]
Either the Registry is corrupted or another application is using the Registry.
Try closing other running applications.
Cannot write the phone book file.
[Remote Access Service]
The Remote Access Service uses the RASPHONE.PBK file in the \SYSTEM32\RAS subdirectory of your Windows NT directory.
Make sure your disk is not full and that you have write access to this file.
Cannot write to the disk. There may be a problem with your disk or network connection. Check your disk or network connection, correct the problem, and then try again.
[MIDI Mapper (Control Panel)]
This message should appear only when you attempt to edit an object that has been saved to a network connection that is no longer available, or when the disk is write-protected.
Check your network connections. If the disk is write-protected, remove its write protection.
Cannot write to the file. Make sure the disk is not full or write-protected.
[Registry Editor]
The Registry Editor cannot write to the file.
Make sure that the disk is not write protected. Check to see that the amount of free space on the disk is equal to or greater than the size of the file. Then try again.
Cardfile cannot save filename.
[Cardfile]
When you make changes to a file, Cardfile locates these changes in a temporary file until you save these changes. Currently, the temporary file cannot be created.
Check to ensure that you are not low on disk space. Then, open your AUTOEXEC.BAT file and ensure that it contains both a TEMP and a TMP setting.
CD Player: Fatal Error
[CD Player]
An error was encountered by the CD Player program that will cause the program to stop.
Use Event Viewer to find out what errors preceded this one. Then look up those errors and take the appropriate action.
Challenge thread is shutting down due to some error condition.
[WINS Service]
Other activity on the computer has affected the activity of the specified thread.
Reboot the WINS server. If you still get this message, restore the WINS database from a backup copy.
Changes have been made to your disk configuration. Do you want to save the changes?
[Disk Administrator]
When you make changes in Disk Administrator, and then attempt to exit the application, you are presented with this standard confirmation message.
If you want to save the changes to your disk configuration, choose Yes. If not, choose No.
Changes have been made which require you to restart your computer. Click OK to initiate system shutdown.
[Disk Administrator]
Any time that you make changes to your disk configuration, you must restart your computer for these changes to take effect.
Choose the Shutdown option that is presented to you in Disk Administrator. If this attempt fails, shut down your system from Program Manager.
Changes will not be saved. Exit setup?
[Remote Access Service]
Cancel was chosen after some changes were made to the configuration of RAS.
Choose Yes to Exit Setup or choose No to continue configuring RAS.
Changing machine account password for account name failed with the following error: text
[Network] Net Message ID: 3224
This server found an error while changing the computer's password at the domain controller.
If you are using Windows NT, ask your network administrator to set your computer value back to the default value. Then, using the Services option in Control Panel, leave and rejoin the domain. If you are using Windows NT Advanced Server, use the Synchronize With Domain option in Server Manager to synchronize the servers.
Changing the computer name will not take effect until the system is restart. Do you wish to continue?
[Control Panel]
You chose to change the name of your computer, and this is a standard confirmation message.
If you choose to restart, the system will restart immediately.
Changing the computer name without the domain administrator first changing its name on the domain will result in domain
[Control Panel]
When a computer logs on to the domain, the computer name is compared to the list of computer names that the administrator has given to the domain. If the computer name of this computer does not match a name on this list, no one can log on from this computer, and no one can access this computer from elsewhere in the domain.
If you are sure you want to change the computer name (for example, if the administrator has already changed the name on the domain), choose Yes. Otherwise choose No.
Changing the domain name will require you to change the domain name on all Advanced Servers and Windows NT workstations in the domain. Also, any trust relationships with other domains will have to be reestablished using the User Manager for Domains. Are you sure you want to do this?
[Control Panel]
After you change the domain name, this domain will not be recognized by any Windows NT Servers, Window NT Workstations, or other domains until the name has been changed on those computers or domains.
Choose Yes to change the domain name, or No to cancel the change.
Changing the Startup Type for the name device may leave the system in an unusable state. Do you want to make the change?
[Server Manager]
The device might be needed to allow the system to start.
Check your documentation to make sure you want to change the startup type for this device.
Check printer on name name
[Network]
Something has stopped the indicated printer. It might be jammed, or out of paper or other supplies.
Check the printer.
Child windows cannot have menus.
[Kernel32]
An application, as part of its user interface, has tried to use a menu on a child window.
Contact the supplier of the running application.
CHKDSK cannot delete all corrupt directory entries.
[Chkdsk]
Due to resource constraints, Chkdsk could not remove all corrupt directory entries.
Run Chkdsk /f again.
CHKDSK could not create a directory to hold recovered files.
[Chkdsk-HPFS]
Delete any unneeded files and run the Chkdsk command with the /f switch again.
CHKDSK could not ensure the consistency of the recovered files.
[Chkdsk-HPFS]
Run the Chkdsk command with the /f switch again.
Chkdsk could not schedule this volume to be checked the next time the system boots.
[Chkdsk]
Chkdsk either couldn't mark the volume for checking using the file system FSCTL, or it couldn't insert the appropriate entries in the Registry.
Contact technical support.
CHKDSK detected an allocation error on the volume.
[Chkdsk-HPFS]
Use the Chkdsk command with the /f switch to correct the problem.
CHKDSK detected minor inconsistencies on the drive.
[Chkdsk]
CHKDSK found file system inconsistencies on the volume which do not affect file system usage.
No action is needed. The inconsistencies can be safely ignored.
CHKDSK discovered free space marked as allocated in the MFT Bitmap.
[Chkdsk-NTFS]
Chkdsk will mark the space as free so the file system can use it.
No action is needed.
CHKDSK discovered free space marked as allocated in the Volume Bitmap.
[Chkdsk-NTFS]
Chkdsk will mark the space as free so the file system can use it.
No action is needed.
CHKDSK does not run on CD-ROM drives.
[Chkdsk]
You cannot use Chkdsk on the specified drive, which is a read-only CD-ROM drive.
CHKDSK found lost data on the disk.
[Chkdsk]
CHKDSK has found data on the disk which it may be able to recover. If any files are recovered, they will appear in FOUND.xxx.
No action is needed.
CHKDSK was not able to delete all corrupted files.
[Chkdsk-HPFS]
Run the Chkdsk command with the /f switch again to delete the rest of the corrupted files.
CHKDSK was not able to resolve all hotfix references on the drive.
[Chkdsk-HPFS]
When the HPFS file system cannot write data to its proper place on the disk, it writes the data to a temporary replacement sector; these are called hot fixes. The Chkdsk utility is attempting to move the data it found in a temporary replacement sector to its correct location on the disk, but not enough disk space is available.
Delete any files you do not currently need from the disk, and then try the Chkdsk command again.
CHKDSK was not able to save all recovered data.
[Chkdsk-HPFS]
The Chkdsk utility found lost data on an HPFS volume, but was unable to recover the data by writing it to the disk in one or more files.
Delete any files you do not currently need from the disk, and then run the Chkdsk command again.
CHKDSK was not able to sort all badly-ordered directories.
[Chkdsk-HPFS]
Delete any unneeded files and run the Chkdsk command with the /f switch again.
CHKDSK was not able to write the bitmap.
[Chkdsk-HPFS]
Delete any unneeded files and run the Chkdsk command with the /f switch again.
CHKDSK was unable to adjust the size of the log file.
[Chkdsk]
There is not enough space to increase the size of the log file, or Chkdsk encountered file system corruption on a clean volume.
Delete some unneeded files and then run Chkdsk /f again.
Circular dependency: The name service depends on a group which starts later.
[Netevent]
The service specified depends on a group which is configured to start later than the specified service.
Ask your system administrator to either change the dependency or change the order of the GroupOrderList in the Registry.
Circular dependency: The name service depends on a service in a group which starts later.
[Netevent]
The service specified depends on another service that is in a group which is configured to start later than the specified service.
Ask your system administrator to either change the dependency or change the order of the GroupOrderList in the Registry.
Circular service dependency was specified.
[Kernel32]
An application tried to change the service dependency list for a service. A check of the other service dependency lists in the service database reveals at least one circular relationship between the proposed new list and existing lists. For instance, service A must start before service B in one list, but service B must start before service A in another list. Your computer has not been configured properly.
The system may not have been setup properly to run this application. Contact your system administrator.
Class already exists.
[Kernel32]
An application tried to register an application-specific window class with the system that had already been registered.
Contact the supplier of the running application.
Class does not exist.
[Kernel32]
An application tried to use an application-specific window class that had not been registered.
Contact the supplier of the running application.
Class still has open windows.
[Kernel32]
An application, as part of its user interface, has tried to unregister a class of windows, but there is at least one window of that class open in the user interface.
Contact the supplier of the running application.
Close an application and try again.
[Program Manager]
The applications that you have running are making demands on your computer's available memory that make it impossible for it to perform the requested operation.
Choose OK, close some of the applications that you have running, and then try again.
Code page operation not supported on this device
[Mode]
You have specified an invalid device and code page combination.
The Windows NT Mode command does not support changing code pages on an LPTn: device.
Command cannot be processed because the server application is busy. Wait until the server becomes available. Or try to determine which application is busy, switch to it, and then complete or cancel the action which is causing it to be busy.
[Cardfile]
A server application is the application providing the object that you want to link or embed into this Cardfile file.
Follow the user action specified in the message.
Command line too long.
[Virtual DOS Machine (VDM)]
NTVDM was unable to use the command line in the PIF file.
Use the PIF editor to change the command line in the PIF file.
Command missing from syntaxUsage : OS2 /C [path]command [args]
[OS/2 Subsystem]
The command has failed because incorrect parameters were used. The correct syntax is OS2 /P [<path>]command [<args>]
Try again, using the correct syntax for the command and the arguments.
Command read-after-write error. From device: name
[QIC117]
There is potentially a serious problem with the device.
Contact the hardware manufacturer or technical support.
Compare error on side number, track number
[Disk Compare]
The floppy disks are not identical. They differ on the specified side and track. The comparison of these two particular disks failed.
Component configuration file name missing in Registry
[Control Panel]
A file that is necessary to your configuration is missing from the Registry. Therefore, the current operation cannot be completed.
Contact technical support.
Component configuration option value missing in Registry
[Control Panel]
A value entry necessary to your configuration is missing in the Registry. Therefore, the current operation cannot be completed.
Contact technical support.
Component key missing from Configuration Registry
[Control Panel]
A component key necessary to your configuration is missing in the Registry. Therefore, the current operation cannot be completed. This message is most likely to appear after a new network component has been installed.
Reboot the computer and try again. If you still get this error remove the recently installed network component and reboot the computer, then reinstall it and reboot the computer again. If the problem continues, ask the administrator to edit the registry, removing the variable \Software\Microsoft\Ncpa\CurrentVersion\Bindfile; then choose Network from the Control Panel and choose Binding to redo the binding.
Computer name change cannot be changed at the same time as domain or workgroup information.
[Control Panel]
Finish changing the domain or workgroup information, then change the computer name.
Computer name not found
[Performance Monitor]
The computer you specified is not currently online, or the computer name was mistyped. Or, you do not have permission to access this computer, particularly if it is in a different domain.
Make sure the computer is running on the network and then try again, making sure that you have the correct computer name and that it is typed correctly. If you still get this message ask the network administrator to make sure you have permission to access that computer.
Computer not responding
[Performance Monitor]
The remote computer whose performance you are trying to monitor is not answering requests for data.
Make sure the computer is currently running on the network.
Computer name mask is not valid.
[WINS Service]
You specified an invalid computer name, or used wildcard characters incorrectly, in the Computer Name text box of the Filter.
Make sure that, except for wildcard characters, you have entered a valid computer name. The asterisk (*) wildcard can only be placed at the end of the computer name; the question mark (?) wildcard can appear anywhere.
Configuration operation attempt failed
[Control Panel]
When this message appears, you should have seen directly preceding it a message that more specifically addressing the problem.
If this message fails to help you, contact technical support.
Configuration operation was canceled by user
[Control Panel]
You canceled the setup of a software component or network adapter card. Any changes that were made will not take effect.
No action is needed.
Configuration Registry is currently locked by another process
[Control Panel]
Possibly, you attempted to activate another Setup application at the same time that you are using the Network option.
Wait until the other application that is using the process is complete, then try again.
Connect request failed
[TFTP]
The Tftp utility could not begin the file transfer process because it could not establish a network connection with the remote computer. The remote computer may be too busy at the moment, or out of resources.
Wait, then retry the Tftp command. If you still get this message, ask your network administrator to check what is happening at the remote computer.
Connection closed by remote host.
[FTP Server]
If you expected this message, no direct user action is necessary. If it is unexpected, ask your network administrator to check the condition of the remote computer.
Connection refused text
The attempt to connect was not successful.
Connection to device name has been lost.
[Backup]
There is no longer a connection to the named device. The physical connection (for example, the cable) may be loose, or the device may have been turned off, or in the case of a device connected to a remote computer, the remote computer may be turned off.
Make sure the physical connections are secure, that the device is turned on, and that any computer acting as a server for the device is turned on.
Connection was aborted by the remote client
[WINS Service]
Make sure that the remote WINS server and the router are both running. Then try again.
Consult your User's Guide and Reference before using the RECOVER command.
[Recover-FAT/HPFS]
Recover recovers readable data from a bad or defective disk. Data could be lost if you use the Recover command without knowing the restrictions of the command.
Continuing will cancel the connections.
[Network]
You had open connections on the network when you issued the net stop workstation command. If you have files open on any of the connections listed before this message appeared, and you continue to stop the workstation service, the files could be corrupted.
If you are sure you have no open files on any of your network connections, answer Yes to continue. Otherwise, answer No, close the open files, and try again.
Control ID not found.
[Kernel32]
An application, as part of its user interface, has requested an operation on a control (BUTTON, LISTBOX, SCROLLBAR, etc.) that does not exist in the user interface.
Contact the supplier of the running application.
Conversion ceased due to error.
[Aclconv]
The Aclconv utility was unable to convert an access control list.
Examine the log file you specified as a parameter in the Aclconv command. Resolve any problems that are listed there, then try the conversion again. Before you try again, free up as many Windows NT resources as you can. If this message persists, you will have to apply the file permissions manually, using File Manager.
Convert cannot gain exclusive access to the drive letter drive, so it cannot convert it now. Would you like to schedule it to be converted the next time the system reboots (Y/N)? text
[Convert]
A user or system process is using the specified drive. User processes are processes executed by running applications. System processes are processes from volumes with active paging files. An active paging file cannot be locked.
Stop other running applications and try the conversion again. Or, type Y and Convert will schedule the volume to be converted the next time the system restarts.
Convert cannot read the name translation table from filename .
[Convert]
Autoconv could not read the filename translation table created by Convert.
Run the Convert command again. Ensure that the file containing the filename translation table is not erased before the system is restarted.
Convert cannot write the name translation table to disk.
[Convert]
Either there is insufficient free space on the volume to write the name translation table, or the write failed which indicates that there are bad sectors on the volume.
Remove any unneeded files to free disk space. Also run Chkdsk /r to map bad sectors out of free space.
Convert directory to file (Y/N)? text
[Convert]
If a directory is too corrupt to repair, it can be converted into a file or released into free space.
Choose Yes to convert the directory into a file. Choose No to release the directory's clusters into free space.
Convert encountered a name in the root directory which could not be converted to Unicode.
[Convert]
Rerun Convert with the Nametable option, or delete files with extended characters in their names from the specified directory.
Convert encountered a name which could not be converted to Unicode in the directory name .
[Convert]
Rerun Convert with the Nametable option, or delete files with extended characters in their names from the specified directory.
Convert encountered duplicate names in the directory name .
[Convert]
Convert detected duplicate names in the specified directory. Convert failed because duplicate names are not allowed in the target file system.
Rename or delete files with duplicate names in the specified directory. Note that Convert recognizes as duplicates any names which differ only by case. For example, Convert would consider Differ.txt and differ.txt duplicate filenames.
Convert lost chains to files (Y/N)? text
[Chkdsk]
FAT Chkdsk has found chains of clusters that do not belong to any file. These chains can be converted to files in which case they will appear as FILExxxx.CHK in FOUND.xxx, or they can be released to free space.
Choose Y to recover the data as files. Choose N to release the data to free space.
Copy Disk Error
[File Manager]
The attempt to copy the disk failed.
Check the Event Log in Event Viewer for messages involving the disks you were copying to and from. Look up those messages, take appropriate action, and try again.
Copy process ended
[Disk Copy]
Diskcopy stopped because an error occurred. Another message about the error should follow this one.
No action is needed.
Correcting error in index number for file filename .
[Chkdsk]
Chkdsk found an error in the specified index and is correcting it.
No action is needed.
Correcting errors in the MFT mirror.
[Chkdsk-NTFS]
The backup copy of the beginning of the master file table was corrupt. Chkdsk is correcting this error.
No action is needed.
Corrupt Attribute Definition Table. CHKDSK is assuming the default.
[Chkdsk-NTFS]
The Attribute Definition Table on the NTFS volume is corrupt. NTFS will replace it with the default table.
No action is needed.
Corrupt master file table. CHKDSK aborted.
[Chkdsk-NTFS]
Chkdsk could not interpret the master file table or its mirror on the NTFS volume.
Reformat the NTFS volume. Then restore the data from a backup.
Corrupt Uppercase Table. Using current system Uppercase Table.
[Chkdsk-NTFS]
Chkdsk found that the table stored on volume to convert filenames to uppercase for collation was corrupt. Chkdsk has fixed this table.
No action is needed.
Could not accept on a socket
[WINS Service]
The computer was unable to accept a connection.
Reboot the computer.
Could not access name : name
[Print Manager]
An error occurred when you attempted to access a printer from Print Manager.
See the event log in Event Viewer for details on the error. Or contact your system administrator.
Could not add port: name
[Print Manager]
An error occurred when you attempted to add a port in Print Manager.
See the event log in Event Viewer for details on the error. Or contact your system administrator.
Could not add the form: name
[Print Manager]
The indicated system error prevented Print Manager from adding the form to the printer.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not allocate a responder association
[WINS Service]
WINS was unable to perform a preliminary task due to a shortage of some resource.
Check the amount of free disk space, and delete some files if necessary. Then reboot the computer.
Could not allocate a UDP Buffer
[WINS Service]
The WINS server is short of some resource, probably memory.
Close some applications and try again.
Could not allocate an explicit dialogue
[WINS Service]
The WINS server is short of some resource, probably memory.
Close some applications and try again.
Could not allocate an implicit dialogue
[WINS Service]
The WINS server is short of some resource, probably memory.
Close some applications and try again.
Could not allocate an initiator association
[WINS Service]
The WINS server is short of some resource, probably memory.
Close some applications and try again.
Could not bind an address to a socket
[WINS Service]
The WINS server is short of some resource, probably memory.
Reboot the computer.
Could not check volume drive letter for errors. The conversion to file system did not take place.
[Convert]
The Autoconv utility cannot run the Chkdsk utility on the target drive to fix any errors that may exist before the conversion is done. This may be because the drive could not be opened for the exclusive write access that Chkdsk needs.
Once your computer restart is complete, run the Convert utility from the command line.
Could not close a socket
[WINS Service]
There was a problem with the TCP/IP stack.
Reboot the computer.
Could not connect to the printer: name
[Print Manager]
The indicated system error prevented Print Manager from making the connection to the printer.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not continue the name service on computer name .Error number : text
[Server Manager]
You are temporarily unable to continue this service on the specified target server, possibly because the computer is temporarily malfunctioning.
See the event log in Event Viewer for details on this error. Then, if necessary, contact technical support.
Could not create a communication subsystem thread
[WINS Service]
The WINS server is short of some resource, probably memory.
Close some applications and try again.
Could not create printer: name
[Print Manager]
An error occurred when you attempted to create a printer in Print Manager.
See the event log in Event Viewer for details on the error. Or contact your system administrator.
Could not delete printer: name
[Print Manager]
The indicated system error prevented Print Manager from deleting the printer. It might be that you do not have permission to delete this printer. Or, the printer might be paused, with jobs waiting, in which case it cannot be deleted
Look up the error message that is included at the end of this message, and take appropriate action. If the printer is paused, resume printing. Also, make sure that you have permission to delete this printer. Then try again.
Could not delete the group group.
[Program Manager]
The specified group has been damaged or deleted from the Registry, and as a result, Program Manager is unable to delete that group.
Attempt to recreate the group, then try again to delete it.
Could not delete the port: text
[Print Manager]
An error occurred when you attempted to delete a port in Print Manager.
See the event log in Event Viewer for details. Or contact your system administrator.
Could not determine the selected server. Try reselecting the server.
[Services for Macintosh (SFM)]
If reselecting the server does not work, try restarting the application. Also try restarting your system. Otherwise, contact technical support.
Could not determine the type of input.
[Network] Net Message ID: 2357
A software error occurred.
Contact technical support.
Could Not Find filename
[Command Prompt]
Command Prompt did not find the file or files that you specified.
Make sure you typed the filename and path correctly.
Could Not Find filename
[Command]
Command Prompt did not find the file or files that you specified.
Make sure you typed the filename and path correctly.
Could not find a domain controller for domain name .
[Network] Net Message ID: 3713
Either this domain does not have logon security and therefore does not have a domain controller, or its domain controller is currently unavailable.
If this domain does not have logon security, you cannot use this domain. Otherwise, retry the command. If the problem persists, ask your network administrator if the domain controller is running.
Could not find domain controller for this domain.
[Network] Net Message ID: 2453
Windows NT could not find the domain controller for this domain. This task cannot be completed unless the domain controller is running in this domain.
Start the Netlogon service on the domain controller.
Could not find file filename Make sure that the required file exists and try again.
[Convert]
The Convert utility could not find the programs that do automatic disk checking and file system conversion in the SYSTEM32 directory (in Version 1.0 of Windows NT, these two programs are named AUTOCHK.EXE and AUTOCONV.EXE). No conversion was done.
Restore those two program files from the Windows NT distribution medium to the Windows NT SYSTEM32 directory (you will have to decompress the files). Then retry the Convert command.
Could not find procedure filename in name .DLL
[Print Manager]
The specified .DLL file is corrupted, or has been overwritten by another file of the same name.
Recopy the specified .DLL from the installation disk(s).
Could not find setup file filename
[Print Manager]
Print Manager was unable to locate a necessary Setup file, most likely PRINTER.INF.
Ensure that this file is in your SYSTEM32 directory.
Could not find subprogram name .
[Network] Net Message ID: 3511
The specified program file could not be found.
Check that the program is in the same directory as NET.EXE, which is usually in your system directory.
Could not find the computer name computer name .
[Network]
The local computer name could not be found. This message rarely appears.
Contact technical support.
Could not find the domain controller for domain name .
[Network]
Either this domain does not have logon security and therefore does not have a domain controller, or its domain controller is unavailable.
If this domain does not have logon security, you cannot use this command. Otherwise, retry the command. If the problem persists, ask your network administrator if the domain controller is running.
Could not free a UDP Buffer
[WINS Service]
The WINS server is short of some resource, probably memory.
Check the memory resources on the computer. Stop and restart the WINS service, or reboot the computer.
Could not invoke help application.
[Disk Administrator]
Either you are low on memory, or the file containing Disk Administrator Help is not present in your Windows NT SYSTEM 32 directory.
If you have applications running, close one or more of them, then try again. If you have no other applications running, do a Search in File Manager for WINDISK.HLP and ensure that this file is in your SYSTEM32 directory.
Could not listen on the listening socket
[WINS Service]
A TCP/IP stack error has occurred. This is a serious and unlikely occurrence.
Call technical support.
Could not load filename device driver.
[Network]
Because this device driver could not be loaded, you will be unable to use the device. The problem could be due to either insufficient memory to load the device driver, or an absent or corrupt file. If this message occurs while starting the Workstation service, the service will not start.
Close some other applications and try again. If you still get this message, make sure the device driver software is on your path and is not corrupt. You might need to re-install the driver.
Could not load any transport.
[Network]
The workstation could not bind to any communications protocols.
Check the event log for other errors that occurred at the same time, and take the appropriate action. Also, choose Network in the Control Panel and make sure the configuration for the installed protocols is correct.
Could not load library filename .DLL
[Print Manager]
The specified .DLL file is corrupted, or has been overwritten by another file of the same name.
Recopy the specified .DLL from the installation disk(s).
Could not load library filename .DLL
[Print Manager]
Either the .DLL file referred to in the error message is corrupted or was overwritten by a file of the same name.
Recopy the file from the installation disks.
Could not locate a time-server.
[Network]
No computer is specified as a time-server in the configuration for the Server service.
This setting must be made in the Registry. Set the parameter in HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\LanmanServer\Para eters\TimeSource.
Could not lock the group 'name'.
[User Profile Editor]
An attempt to lock a program group failed, most likely because User Profile Editor is unable to make necessary contact with the Registry key in which user profiles are located. This inability may be due to the permissions that have been set on the key.
In Registry Editor, make sure that the security on the key for the program group(s) that you are attempting to lock allow you Create Subkey, Delete, and Set Value permissions.
Could not look up the assoc block for an NBT association. Check if the message read is corrupted. WINS looks at bit 11-14 of the message to determine if the assoc. is from another WINS or from an NBT node. It is possible that the bits are corrupted or that there is a mismatch between what the two WINS servers expect to see in those bits (maybe you changed the value to be put in code and not increment the version number sent during assoc. setup.
[WINS Service]
Contact technical support.
Could not open name : name
[Print Manager]
An error occurred when you attempted to open a printer.
Consult this database for a detailed explanation of the second half of this message. Or see the event log in Event Viewer for details.
Could not open the file: filename
[Print Manager]
The system might be running low on disk space or access to the file might have been denied. Other problems might have occurred, but they should be specified in the message.
If you can, correct the problem specified in the message, otherwise, contact your system administrator.
Could not open the printer: name
[Print Manager]
An error occurred when you attempted to open a printer.
Consult this database for a detailed explanation of the second half of this message. Or see the event log in Event Viewer for details.
Could not pause document: name
[Print Manager]
The indicated system error prevented Print Manager from pausing the document.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not pause printer: name
[Print Manager]
The indicated system error prevented Print Manager from pausing the printer.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not pause the name service on computer name .Error name : text
[Server Manager]
You are temporarily unable to pause the specified service on the target server, possibly because the server is not started.
See the event log in Event Viewer for details on the error.
Could not purge printer: name
[Print Manager]
The indicated system error prevented Print Manager from purging all documents from this printer.
Look up the error message that is included at the end of this message, and take appropriate action. Also, make sure you have Full Control privileges on this printer. Then try again.
Could not read from NETBT
[WINS Service]
The WINS service will terminate due to this error.
Choose Network from the Control Panel and make sure the TCP/IP driver is installed and running. Then restart WINS.
Could not read from the UDP socket.
[WINS Service]
WINS was unable to receive a name packet.
Stop the WINS service. Then choose Network from the Control Panel and make sure the TCP/IP driver is installed and running. Finally, restart WINS.
Could not read the current virtual memory settings.
[Program Manager]
The System applet in the Control Panel cannot read Page File information from the Registry. The Registry is probably corrupt.
Contact technical support. The value of REG_MULTI_SZ in HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\SessionManager|MemoryManagement|\PagingFiles needs to be checked by someone who is an expert user of Regedit32.
Could not register control handler with service controller name .
[Network] Net Message ID: 5724
The service controller did not start.
Check the event log with Event Viewer for more details about related errors.
Could not restart the document: text
[Print Manager]
The indicated system error prevented Print Manager from restarting the document.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not resume printing document: filename
[Print Manager]
Either the .DLL file referred to in the error message is corrupted or was overwritten by a file of the same name.
Recopy the file from the installation disks.
Could not resume printing document: name
[Print Manager]
The indicated system error prevented Print Manager from resuming printing of the document.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not resume printing: text
[Print Manager]
The indicated system error prevented Print Manager from resuming printing.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not run SETUP: text
[Print Manager]
The indicated system error prevented Print Manager from creating a process for Setup.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not save settings to Registry Serial Parameters area.
[Program Manager]
Either security settings prevent access to the required Registry keys, or the Registry is corrupt.
Contact technical support. The keys in Machine\System\CurrentControlSet\Services\Serial\Parameters need to be checked by someone who is an expert user of Regedit32.
Could not schedule an automatic conversion of the drive.
[Convert]
The Convert utility tried to schedule an automatic file system conversion of a drive because it could not be done now (because, for example, the drive could not be locked). The conversion could not be scheduled.
Make sure you have the privileges associated with the administrator group.
Could not set logon information for this user.
[Network] Net Message ID: 2454
This message should occur only on a down-level computer. Any action to correct the problem should be performed on that computer. The logon server could not update the logon or logoff information.
Stop and restart the Netlogon service at the server that returned this error.
Could not set printer: name
[Print Manager]
The indicated system error prevented Print Manager from changing one or more settings for this printer.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not set service status with service controller name .
[Network] Net Message ID: 5725
The service controller did not start.
Check the event log with the Event Viewer for more details about the service errors.
Could not set the device mode for this printer: text
[Print Manager]
The indicated system error prevented Print Manager from creating a new printer or changing job defaults.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not set the document details: text
[Print Manager]
The indicated system error prevented Print Manager from changing the details for a document.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not set the form: name
[Print Manager]
The indicated system error prevented Print Manager from setting the form.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not set the position of the document: text
[Print Manager]
The indicated system error prevented Print Manager from setting the position of the document.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not show help.
[Print Manager]
Help cannot be displayed for Print Manager. You may be low on system resources. Or PRINTMAN.HLP may be missing from your SYSTEM32 directory.
If you have a number of applications running, try closing some of them, then try again. Or place PRINTMAN.HLP in your SYSTEM32 directory.
Could not show help.
[Print Manager]
An error occurred when you attempted to open a printer.
Consult this database for a detailed explanation of the second half of this message. Or see the event log in Event Viewer for details.
Could not start one or more of the NetDDE related services. Consult your system administrator for help.
[Dynamic Data Exchange]
One or more of the following services cannot be started, possibly because it is disabled: ClipBook Server Network DDE Network DDE DSDM
Choose Services from the Control Panel and make sure these services are not disabled.
Could not start the name device on computer name .Error number : text
[Server Manager]
You are temporarily unable to start the specified device on the target server.
See the event log in Event Viewer for details on the error.
Could not start the name service on computer name .Error number : text
[Server Manager]
You are temporarily unable to start the specified service on the target server.
See the event log in Event Viewer for details on the error.
Could not stop the name device on computer name .Error name : text
[Server Manager]
You are temporarily unable to stop the specified device on the target server, possibly because the server is not started.
See the event log in Event Viewer for details on the error.
Could not stop the name service on computer name .Error number : text
[Server Manager]
You are temporarily unable to stop the specified service on the target server, possibly because the server is not started.
See the event log in Event Viewer for details on the error.
Could not transfer the file because of an invalid packet number. Try sending or receiving the file again.
[Terminal]
The term packet number designates the number of bits in a data packet. Most characters are transmitted in 7 or 8 data bits, though some computers require a setting of 5 or 6 data bits. You specified in the Communications dialog box a number of data bits Terminal cannot send.
Select the Communications option on the Settings menu, and select a different number of bits for your data packet.
Could not transfer the file because of too many tries to send or receive a data packet. Try sending or receiving the file again.
[Terminal]
When you use KERMIT protocol to send a packet, and there is a crash or malfunction on the system to which the packet is being sent, Terminal limits the times that you can try to send or receive a data packet.
When this occurs, you must begin again the entire process of sending or receiving a file.
Could not update the security descriptor for this printer: text
[Print Manager]
The indicated system error prevented Print Manager from updating the security descriptor for this printer.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Could not view the printer properties: text
[Print Manager]
The indicated system error prevented Print Manager from displaying the properties for this printer.
Look up the error message that is included at the end of this message, and take appropriate action. Then try again.
Couldn't determine user's logon name
[TCP/IP]
A TCP/IP utility that performs remote operations is trying to match a Windows NT user's unique security identifier (SID) with their user name and is unable to do so. This can happen, for instance, when a domain controller is not running and the utility is unable to make the match using the user names cached on your computer.
Log on to your computer with a user name that is sure to be recognized by the local computer without the use of a domain controller.
Critical resource missing from resource file
[Control Panel]
The binary file that enables the current process is corrupted. Or you are very low on memory.
If you have a number of applications running, close one or more of these, then try again. Or contact technical support.
Currency symbol cannot be empty or contain digits
[Program Manager]
The Symbol text box in the International - Currency Format dialog is blank or contains a number.
Enter one or more letters or symbols in this text box.
Current disk configuration information will be overwritten! Are you absolutely sure you want to continue?
[Disk Administrator]
If you continue, the current disk configuration information will be replaced with the specified configuration. It is advisable to have a backup copy of this information before continuing.
Current File: filename Continue to finish writing this file to disk, or Abort the restore immediately without finishing the current file.
[Backup]
A file is being written to the disk. You can either finish writing this file, or stop writing immediately.
Choose Continue to finish writing this file to disk, or choose Abort to stop the backup immediately.
Current File: filename Continue to finish writing this file to tape, or Abort the backup immediately without finishing the current file.
[Backup]
A file is being written to the tape. You can either finish writing this file, or stop writing immediately.
Choose Continue to finish writing this file to tape, or choose Abort to stop the backup immediately.
Current keyboard does not support this code page
[Mode]
Use the International option in Control Panel to select a valid code page.
Current tape is from a different tape family.
[Backup]
The tape that was just inserted is from another tape family. A tape family is a group of tapes in which backup data is continued from one tape to the next. A tape family can have one or more backup sets.
Remove the tape, and replace it with a tape from the family that you have been working with.
Current user trusted shares are inaccessible
[Dynamic Data Exchange]
You probably do not have permission to access the key HKEY_CURRENT_USER\Software\Microsoft\NetDDE in the Registry.
An experienced user of Regedit32 should check the permissions on these keys. Or, that person can delete the key and then run Setup to re-configure these keys.