ACC2: Workstation Setup Option Not Available with DEC PathworksLast reviewed: May 28, 1997Article ID: Q116064 |
The information in this article applies to:
SYMPTOMSModerate: Requires basic macro, coding, and interoperability skills. The Workstation Installation option is not available when you are trying to set up a workstation after setting up a DEC Pathworks server using the SETUP /A command.
RESOLUTIONTo work around this behavior, place a semicolon (;) at the beginning of the following line in the [MS Setup (ACME) Table File] section of your WIN.INI file:
MSACCESS.EXEv2.00.0010.0USA=C:\ACCESS\SETUP\setup.stf MORE INFORMATIONWhen you try to set up a network installation of Microsoft Access to a DEC Pathworks workstation that already has Microsoft Access installed locally, the local Setup always runs, even though you are connected to a server and running Setup from a shared network directory.
Steps to Reproduce Behavior
REFERENCESFor more information, see the "Network Installations" section of the ACREADME.HLP file. |
Keywords : kbsetup StpNet