XCON: MTA Strips Message Body Using X400 Connector With ISO 6937Last reviewed: July 17, 1997Article ID: Q147022 |
The information in this article applies to:
SYMPTOMSThe Microsoft Exchange Message Transfer Agent (MTA) may fail to deliver the message contents when sending a message across an X400 connector configured to use ISO 6937 body parts.
MORE INFORMATIONThis problem was introduced in version 995.50 of the MTA. This problem is independent of the type of X400 MTA that receives the message that originates from Microsoft Exchange. Messages will be delivered successfully to the intended recipients but the message body will be missing. This problem will only occur when using MTA builds 995.50, 995.51, 995.52, and 995.53 when an X400 connector is configured as follows:
General Tab ----------- Remote Clients Support MAPI is not checked Advanced Tab ------------ ISO 6937 Body Part is checked Allow MS Exchange Contents is not checked RESOLUTIONMicrosoft has confirmed this to be a problem in Microsoft Exchange Server version 4.0. This problem has been corrected in the latest Microsoft Exchange Server version 4.0 U.S. Service Pack. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K |
Keywords : kbbug4.00 kbfix4.00.sp4 XFOR kbfix4.00
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |