XADM: MTA Restart Fails and Logs Error 2051Last reviewed: April 7, 1997Article ID: Q157058 |
The information in this article applies to:
SYMPTOMSAfter a failure and a subsequent failed restart attempt, the Microsoft Exchange Server Message Transfer Agent (MTA) logs an event similar to the following:
Event ID: 2051 Source: MSExchangeMTA Description: A fatal internal MTA error occurred. Contact Microsoft Product Support Services. An illegal GET from element 3CB84D01 occurred at offset 2073. [BASE DISP:FANOUT 14 8] (16) CAUSEIf a failure occurred during the processing of a message, upon restart, key routing information for some addresses on the recipients list may not be consistent, causing the fatal error described above.
STATUSMicrosoft has confirmed this to be a problem in Microsoft Exchange Server version 4.0. This problem was corrected in the latest Microsoft Exchange 4.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K Keywords : kbbug4.00 kbfix4.00.sp4 XADM kbusage Version : 4.0 Platform : WINDOWS Issue type : kbbug Solution Type : kbfix |
================================================================================