XFOR: Installing the Proxy Address Generator for Exchange-SNADS

Last reviewed: February 25, 1998
Article ID: Q169629
The information in this article applies to:
  • Microsoft Exchange Server version 5.0

SUMMARY

In a multiple-site environment, sites other than the site where LinkAge Message Exchange is installed need the proxy generator and the address template to send and receive mail with the connected systems.

The following steps are necessary to install the proxy generator and the address template for the LinkAge Exchange-SNADS Connector on a site that is separate from the site where the connector is installed.

  1. The following files are required for these steps and can be obtained from the C:\Linkage\Install directory, located on the currently installed LinkAge connector.

    - Mexitmpl.exe - Mexiaddr.exe - Ibmpxgen.dll - Ibmscr.blt - Ibmadt.blt - Ibmadt.hlp

  2. Create a C:\Linkage\Install directory on the Exchange Server computer in the site where the proxy generator and the address template are to be installed, and copy the above files into this directory.

  3. Create the following directory where the SNADS proxy address generator will exist:

          \\MEXServerName\Address\SNADS\I386
    

  4. Copy the following file into the directory created in step 3:

          Ibmpxgen.dll
    

  5. To install the SNADS address template on the Exchange Server computer, run the following command from the C:\Linkage\Install directory:

          mexitmpl "/org=MEXOrganization" "/site=MEXSite"
          "/Server=MEXServerName"
          /ADDRTYPE=SNADS /SYNTAX=c:\linkage\install\ibmscr.blt
          /ADDRESS_DT=c:\linkage\install\ibmadt.blt  /LANGUAGE=409
          /FILE=c:\linkage\install\ibmadt.hlp
          /DATA16=c:\linkage\install\ibmadt.hlp
          /DATA32=c:\linkage\install\ibmadt.hlp /SF
    

  6. Check the following files to see if any errors occurred with the above command:

    - Lmeistat.txt - Lmeilog.txt

  7. To install the proxy address rule and to optionally generate proxy addresses, run the following command from the C:\Linkage\Install directory:

          mexiaddr "/org=MEXOrganization" "/site=MEXSite"
          /Server=MEXServerName"
          /ADDRTYPE=SNADS /MACHINE=I386 "/PROXYRULE=SNADS:nodeid(&m)"
          /PROXYDLL=c:\linkage\install\ibmpxgen.dll  /SF
    

    Replace nodeid with the node ID assigned to the connector.

    If proxy addresses are NOT to be generated, then insert /NOGENADDR before the /SF.

  8. Check the following file to see if any errors occurred with the above command:

    - Lmeistat.txt - Lmeilog.txt

Keywords          : XFOR
Version           : WINDOWS:5.0
Platform          : WINDOWS
Issue type        : kbhowto


================================================================================


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: February 25, 1998
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.