XCON: IMS Does Not NDR Message When Passed DISP_NDR_ORIGLast reviewed: February 12, 1998Article ID: Q178378 |
The information in this article applies to:
SYMPTOMSThe Microsoft Exchange Server Internet Mail Service does not send a non- delivery report (NDR) on a message it has passed from a custom routing .Dll file with DISP_NDR_ORIG. The message may be delivered to the mailbox and the following event ID recorded:
Event id 2078 from MSExchangeIS Private Category: Transfer Out Of Gateway Description: Unable to submit, send or transfer out a message. Check PR_DELIVERY_TIME, PR_NDR_REASON, PR_NON_DELIVERY_DIAGNOSTIC. CAUSEThe Microsoft Exchange Server Internet Mail Service will attempt to resolve the name and deliver the message if a valid address is available in the message. If the address in the recipient list is not valid, the message transfer agent (MTA) will send an NDR. If the address is resolved, then the MTA will attempt to deliver the message.
STATUSMicrosoft has confirmed this to be a problem in Microsoft Exchange Server version 5.0. This problem has been corrected in the latest U.S. Service Pack for Microsoft Exchange Server version 5.0. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K |