FORTRAN PowerStation ADDENDA.TXT

Last reviewed: July 21, 1995
Article ID: Q105933
The information in this article applies to:
  • Microsoft FORTRAN PowerStation for MS-DOS, versions 1.0 and 1.0a

SUMMARY

The corrections to the manuals shipped with Microsoft FORTRAN PowerStation for MS-DOS are described below. This is an extract of the ADDENDA.TXT file located in the \F32\README directory.

MORE INFORMATION

Part 1: Corrections to Getting Started

There are no corrections to Getting Started.

Part 2: Corrections to Language Guide

Page 52 Add the following note to the second bullet describing an iolist: "If I/O is to or from a formatted device, an iolist may not contain structure variables, but it may contain structure elements. If I/O is to a binary or unformatted device, it can contain either a structure element or a structure variable."

Page 85 Add the following comment to the discussion of backslash editing: "The dollar sign ($) can be used as an alias for the backslash edit descriptor."

Page 129, 131 Delete the table entries for GETCONFIGQQ.

Page 199 Input to intrinsic function ABS can also be any real or integer type.

Page 203 The purpose of intrinsic function AMAX0 should read: "Returns the maximum of a list of integer values."

Page 203 The purpose of intrinsic function AMAX1 should read: "Returns the maximum of a list of integer values and performs type conversion."

Page 204 The purpose of intrinsic function AMIN1 should read: "Returns the minimum of a list of integer values and performs type conversion."

Page 214 The order of the parameters for BEEPQQ is reversed; frequency is the first parameter. The frequency parameter in should be Hz, not KHz. The duration should be in milliseconds.

Page 256 One of the examples for the DINT intrinsic function is documented incorrectly. The examples show:

   DINT(2.6D0)       2.0000 ....
   DINT(2.6D0)      -2.0000 ....
The second line should read: (note the minus sign in the argument)
   DINT(-2.6D0)     -2.0000 ....

Page 314 Change error parameters ENOENT and EINVAL to ERR$NOENT and ERR$INVAL.

Page 319 The first five fontinfo structure variables in graphic function GETFONTINFO (type, ascent, pixwidth, pixheight and avgwidth) are shown as Integer*2; they should be Integer*4.

Pages 322-323 The naming convention for run-time error parameters was documented incorrectly. The following table shows the actual names of these parameters in the FLIB.FD include file:

   Change        to
   ========      =========
   E2BIG         ERR$2BIG
   EACCES        ERR$ACCES
   EBADF         ERR$BADF
   EINVAL        ERR$INVAL
   EIVAL         ERR$IVAL
   EMFILE        ERR$MFILE
   ENOENT        ERR$NOENT
   ENOEXEC       ERR$NOEXEC
   ENOMEM        ERR$NOMEM
   ERANGE        ERR$RANGE

Page 338 The Remarks section states that error constants are in FGRAPH.FI. Actually they are in FGRAPH.FD.

Several error constants were omitted from the table:

   $GRTEXTNOTSUPPORTED     (  4)
      The VESA TSR or BIOS sets a flag that may indicate that text output
      is not supported. (Note: this flag is used inconsistently by
      different hardware vendors and may not be significant.)
   $GRNOBITMAPFILE         (-10)
   $GRFILEREADERROR        (-11)
   $GRIMPROPERBITMAPFORMAT (-12)
   $GRBITMAPTOOLARGE       (-13)
   $GRBITMAPDISPLAYERROR   (-14)
   $GRIMAGEREADERROR       (-15)
   $GRFILEOPENERROR        (-16)
   $GRFILEWRITEERROR       (-17)

The declaration of $GRTEXTNOTSUPPORTED has been omitted from FGRAPH.FD, therefore, you will get the following error when you use this constant and compile with /4Yd:

   warning F4313: $GRTEXTNOTSUPPORTED: not previously declared

To work around this problem, open FGRAPH.FD, go to line 54, and add:

   + $GRTEXTNOTSUPPORTED

Page 376-377 Run-time subroutines SCWRQQ and SSWRQQ were incorrectly used as functions in the sample program TCOPO.FOR.

Page 381-382 Graphic Functions LOADIMAGE and LOADIMAGE_W are INTEGER*2 functions. The coordinate parameters wxcoord and wycoord are DOUBLE PRECISION, not REAL*4.

Page 386 The error parameters for MAKEDIRQQ were documented incorrectly.

   Change      to
   ------      ---------
   EACCES      ERR$ACCES
   ENOENT      ERR$NOENT

Page 439 The error parameters for RENAMEFILEQQ were documented incorrectly.
   Change      to
   ------      ---------
   EACCES      ERR$ACCES
   ENOENT      ERR$NOENT
   EXDEV       ERR$XDEV

Page 444-445 The coordinate parameters (ulwxcoord, ulwycoord, lrwxcoord and lrwycoord) are Double Precision, not Real*4.

Page 457-458 Run-time subroutines GETCONTROLFPQQ and GETSTATUSFPQQ were incorrectly used as functions in the sample program TCOP.FOR. The source for TCOP.FOR in the samples directory and in Help is correct.

Page 462 The error parameters for SETFILETIMEQQ were documented incorrectly.

   Change      to
   ------      ---------
   EACCESS     ERR$ACCES
   EINVAL      ERR$INVAL
   EMFILE      ERR$MFILE
   ENOENT      ERR$NOENT

Page 478 The remarks for Graphics subroutine SETTEXTWINDOW should read:

"Use SETTEXTWINDOW to specify a window in row and column coordinates where text output written to the screen using the OUTTEXT() subroutine is displayed. (You must set up the location with SETTEXTPOSITION.) The arguments (r1, c1) specify the upper-left corner of the text window, and the arguments (r2, c2) specify the lower-right corner of the text window.

Text is output from the top of the text window down. When the text window is full, successive lines overwrite the last line."

Page 496 The duration parameter of run-time subroutine SLEEPQQ should be in milliseconds, not microseconds.

Page 507 The error parameters for SYSTEMQQ were documented incorrectly.

   Change      to
   ------      ---------
   E2BIG       ERR$2BIG
   ENOINT      ERR$NOINT
   ENOEXEC     ERR$NOEXEC
   ENOMEM      ERR$NOMEM

Page 522 Appendix A erroneously states that the following VAX extensions are supported by FORTRAN PowerStation: 1) Inline variable length formatting
   (e.g.: FORMAT('I<var>'), where var = 5)
2) Call intrinsics (%val, %descr, %ref, %loc)

Part 3: Corrections to User's Guide

Page 15, 22 You can also use CTRL+K to find matching braces.

Pages 67-68 The Create Assembly Listing checkbox is documented incorrectly. The compiler option associated with this option is /FAs, not /Fl. This option produces an assembly listing with code bytes, not an assembly listing with source.

Page 109 Add the following to the discussion of syntax coloring. "FORTRAN Visual Workbench displays metacommands in the same color as comments if syntax coloring is activated."

Pages 144-145 A new set of options has been added for producing assembly listings. The syntax is /FA[sc]. Use /FAs to add FORTRAN source lines to the assembly listing, and /FAc to add code bytes to the assembly listing. /FAsc will produce an assembly listing with both FORTRAN source lines and code bytes.

Page 170 Add this to the end of Section 11.2.3 Using Command Files:

The following example demonstrates the use of command files (also known as response files) to provide input to LINK32. Example:

         LINK32 -LIB @MYRESP.RSP

A typical response file might contain:
         -OUT:MYLIB.LIB
         OBJECT1.OBJ
         OBJECT2.OBJ
         (and so forth)

Page 258 Page 294 Page 297 The default floating-point exception behavior is slightly different from that described in the text. By default, run-time errors occur for the INVALID, ZERODIVIDE, and OVERFLOW exceptions. By default, run-time errors occur for the math exceptions except for when you use the compiler option /Ox. See the README.TXT file for a summary of the complete floating-point exception behavior and details on how to customize that behavior to be strictly the IEEE behavior as described in the text.

Page 284 Replace the text:

"Some older 80386 systems have 287 coprocessors instead of 387s; the 287 math coprocessor does not perform floating-point operations on these systems."

with the text:

"Some older 80386 systems have 287 coprocessors instead of 387s; some floating-point operations will not work correctly in these cases. To fix this, you must force use of the floating-point emulator by setting the TNT environment variable as follows. At the MS-DOS (or Windows MS-DOS session) command line, enter "SET TNT=-FPEM" before running your compiled program. To cancel the forced emulation you can enter "SET TNT=-NOFPEM"."


Additional reference words: 1.00 1.00a
KBCategory: kbreadme kbdocerr
KBSubcategory: FORTLngIss


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: July 21, 1995