PRB: Error F2112 Caused by COMPLEX Number VariableLast reviewed: December 11, 1995Article ID: Q39068 |
The information in this article applies to:
SYMPTOMSAn attempt to compile an application developed in Microsoft FORTRAN fails with the following error message:
Error F2112 : I : not symbolic constant.With Microsoft FORTRAN PowerStation 32, version 4.0, this generates:
error FOR3083: invalid real part of COMPLEX constant CAUSEA FORTRAN application cannot directly manipulate complex number variables.
RESOLUTIONUse the CMPLX intrinsic function to manipulate the variable, as follows:
Z = CMPLX(I, 1.2) MORE INFORMATIONOn Page 24, the Microsoft FORTRAN "Language Reference and Mixed-Language Programmer's Guide" for version 4.1 describes the complex data types as follows:
The COMPLEX or COMPLEX*8 data type is an ordered pair of single- precision real numbers. COMPLEX*16 data type is an ordered pair of double-precision real numbers. The first number in the pair represents the real part of a complex number, and the second number represents the imaginary part.For example, the complex number (7, 3.2) represents the number 7.0+3.2i. The following code example demonstrates this error message.
Sample CodeC Compiler options required: None
COMPLEX*8 Z REAL*4 I Z = (I, 1.2) END |
Additional reference words: 1.00 4.00 4.01 4.10 5.00 5.10