FIX: Exiting ON SHUTDOWN Window Disables GET ObjectsLast reviewed: September 22, 1997Article ID: Q124348 |
2.50a 2.50b 2.60 2.60a 3.00
WINDOWS
kbprg kbbuglist kbfixlist
The information in this article applies to:
SYMPTOMSIf an ON SHUTDOWN procedure calls a window that is then exited, the mouse can only access the current GET object in the READ that was active when the ON SHUTDOWN procedure was called.
CAUSEControl is not passed from the ON SHUTDOWN procedure back to the previous READ level if the RELEASE WINDOW command is used.
WORKAROUNDReplace the "RELEASE WINDOW window1" command with the "DEACTIVATE WINDOW window1" command to send control back to the previous screen.
STATUSMicrosoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article. This problem has been fixed in Visual FoxPro 5.0 for Windows.
MORE INFORMATION
Steps to Reproduce Problem
Using DEACTIVATE WINDOW <windowname> in place of RELEASE WINDOW allows the GETS to work as expected.
|
KBCategory: kbprg kbbuglist kbfixlist
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |