BUG: Minimized FoxPro Screen Cannot Be Restored in Windows 95Last reviewed: June 27, 1995Article ID: Q129753 |
The information in this article applies to:
SYMPTOMSIn FoxPro, operating on the Windows 95 beta, if you use the mouse to minimize the screen, the screen cannot be restored. If a screen is minimized by using the "minimize" selection on the right side of the title bar (the underscore), the screen cannot be restored by double-clicking the title bar or by clicking the restore selection portion on the screen (the tiled windows icon). If the screen is minimized by clicking the minimize selection, the Restore function (CTRL+F5) available under the FoxPro Icon on the right side of the title bar does not restore the screen. If you press CTRL+F9 to minimize the screen, you can restore the screen by either pressing CTRL+F5 or by clicking the restore selection. The screen functions normally if you use only the keys to minimize and restore. However, if you press CTRL+F9 to minimize the screen and then use the mouse to restore it. Then you either use the mouse or press CTRL+F9 to minimize the screen again, all the objects and text clear from the screen as though a CLEAR command had been issued.
RESOLUTIONDo not use the mouse to the minimize or restore the screen.
STATUSMicrosoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
MORE INFORMATION
Steps to Reproduce ProblemBuild a screen in the Screen Builder and add, at least, a push button. Then follow the steps in the following examples.
Example One
Example Two
Example Three
|
Additional reference words: FoxWin 2.60a buglist2.60a