SYMPTOMS

When you attempt to start FrontPage, you may see the following error message:

   FrontPage requires 32-bit TCP/IP networking. You do not have 32-bit
   TCP/IP networking installed. Would you like to see help on how to
   install it?

CAUSE

This message appears after you install Windows Sockets (Winsock) 2.0 because FrontPage may not detect that you have TCP/IP installed if a dynamic host configuration protocol (DHCP) server is not available. If you are connected to the network, and a DHCP server is available, FrontPage will operate normally.

RESOLUTION

To resolve this behavior, restore Windows Sockets 1.1 and then install the Windows Sockets 2 update. To do this, follow these steps:

  1. Restore Windows Sockets 1.1.

        a. On the Windows Start menu, click Run.
    

        b. In the Open box, type the following command
    

              C:\<windir>\ws2bakup\ws2bakup.bat
    
           where <windir> is the folder in which you installed Windows.
    
           NOTE: If you receive a message indicating a sharing violation has
           occurred, press the A key to stop running this command. Repeat
           this step until the batch file has finished running and then
           follow these steps:
    
           1) On the Windows Start menu, click Shutdown.
    
           2) Click "Restart the Computer in MS-DOS Mode" and then click
              OK.
    
           3) At the command prompt, type "win" (without the quotation marks)
              and press ENTER.
    
    

  2. Download the Ws2setup.exe file from the following Microsoft World Wide Web site:

          http://www.microsoft.com/windows95/info/ws2.htm
    

    Make a note of which folder you save the Ws2setup.exe file to.

  3. On the Windows Start menu, click Run.

  4. In the Open box, type the following command

          <path>\ws2setup.exe
    

    where <path> is the folder in which you saved the Ws2setup.exe file when you downloaded it. Click OK.

  5. When the Windows Sockets 2 Setup program has finished running, restart the computer. To do this, follow these steps:

        a. On the Windows Start menu, click Shutdown.
    

        b. In the Shut Down Windows dialog box, click Restart and then
           click OK.
    

    After the computer restarts, the Windows Sockets 2 installation will be finished and you will be able to run FrontPage.

MORE INFORMATION

Winsock 2.0 is installed with Microsoft Personal Web Server 4.0 for Windows 95. It is also recommended that you install Winsock 2.0 for use with Dial Up Networking 1.2.

For more information about the Windows Sockets 2 update, please see the "Windows Sockets 2 for Windows 95 Release Notes" document at the following Microsoft World Wide Web site:

   http://www.microsoft.com/windows95/info/ws2relnotes.htm


Additional query words: 97 98 iis mspws tcp ip dialup dial-up wsock32.dll
wsock
Keywords : fpiis fptcp
Technology : internet
Version : WINDOWS:98,97
Platform : WINDOWS
Hardware : x86
Issue type : kbbug
Solution Type : kbfix


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: March 3, 1998
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.