Dr. Watson Error Message After Closing Internet Explorer

Last reviewed: August 28, 1997
Article ID: Q172835
The information in this article applies to:
  • Microsoft Internet Explorer version 3.02 for Windows NT 4.0

SYMPTOMS

When you quit Internet Explorer 3.02, you may receive the following Dr. Watson error message:

   WangImg.exe
   Exception: access violation (0xc0000005), Address: 0x77b50b0e

CAUSE

Internet Explorer 3.02 has not completely closed the hosted Imager program.

STATUS

Microsoft has confirmed this to be a problem in Microsoft Internet Explorer 3.02 for Windows NT 4.0 and will post new information as it becomes available.

MORE INFORMATION

Dr. Watson for Windows NT is a program that detects and diagnoses program errors, and then logs the resulting diagnostic information. In the event of a program error, Dr. Watson for Windows NT starts automatically. Microsoft Technical Support personnel then can use the information logged by Dr. Watson to diagnose problems.

The Wangimg.exe file is a part of Imaging, an accessory included with Windows NT 4.0.


Additional query words: 3.02
Keywords : msient kberrmsg kbtool
Version : WINDOWS:3.02
Platform : WINDOWS


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.