System32 Folder Opens When Windows NT StartsLast reviewed: February 23, 1998Article ID: Q177510 |
The information in this article applies to:
SYMPTOMSAfter you install Internet Explorer, restart your computer, and then log on to Windows NT 4.0, the System32 folder may be opened on your desktop instead of the "Welcome - Microsoft Internet Explorer" screen. In addition, the System32 folder may be opened when you attempt to open a channel. In both cases, the following message is displayed in Event Viewer:
Event ID 10010 The server {0002df01-0000-0000-c000-00000000046} did not register with DCOM within the required timeout. RESOLUTIONTo work around this problem, use either of the following methods:
STATUSMicrosoft has confirmed this to be a problem in Internet Explorer 4.0 and 4.01. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
MORE INFORMATIONFor additional information, please see the following article in the Microsoft Knowledge Base:
ARTICLE-ID : Q170086 TITLE : System32 Folder Opens When Logging in to Windows NT |
Additional query words: 4.00