PRB: Jumping to an Absolute Addresss with MASMLast reviewed: January 9, 1995Article ID: Q49900 |
The information in this article applies to:
SYMPTOMSThe Microsoft Macro Assembler (MASM) will not let you jump directly to a hexadecimal address. If you try to assemble:
jmp 0FFFFh:0000hYou will receive the error message:
A2038: left operand must have segment CAUSEThis is the expected behavior for MASM. To make a jump to an absolute address you must create a pointer to point to the offset inside of the segment.
RESOLUTIONTo create a pointer to point to the offset inside of the segment in question you would create a segment at a specific location. For example:
bios SEGMENT AT 0FFFFh ORG 0 reset LABEL FAR bios ENDSThen, any one of the following three jump instructions will perform the jump to offset 0000h within segment FFFFh:
jmp FAR PTR reset jmp bios:reset jmp resetNote that the opcode that is generated in the listing file is EA 0000 ----
MORE INFORMATIONThis process is covered on Page 101 of the "Microsoft Macro Assembler 5.0: Programmer's Guide." The second paragraph states the following:
An AT segment typically contains no code or initialized data. Instead, it represents an address template that can be placed over code or data already in memory, such as a screen buffer or other absolute memory locations defined by hardware. The linker will not generate any code or data for AT segments, but existing code or data can be accessed by name if it is given a label in an AT segment. |
Additional reference words: 5.00 5.10 5.10a 6.00 6.00a 6.00b bios rom