Call To Undefined Dynalink Error After Installing CorelDRAW!

Last reviewed: March 11, 1998
Article ID: Q160537
The information in this article applies to:
  • Microsoft Publisher 97 for Windows
  • Microsoft Publisher for Windows 95, version 3.0
  • Microsoft Office 97 for Windows
  • Microsoft Office for Windows 95, version 7.0
  • Microsoft PowerPoint 97 for Windows
  • Microsoft PowerPoint for Windows 95, version 7.0

SYMPTOMS

If you install CorelDRAW!, version 5.0 or the Corel CD Office Companion, version 5.0 and then try to start Microsoft Publisher or one of the Microsoft Office programs, you may receive the following error message:

   Call to Undefined Dynalink

Alternatively, the program may fail to start without giving any error message.

CAUSE

Early revisions of CorelDRAW!, version 5.0 and the Corel CD Office Companion, version 5.0 replace version 2.02 of the files Compobj.dll and Storage.dll with an older version of these same files (version 2.01).

These Corel products are designed to run primarily under Windows 3.x and are incompatible with the later version of these files. This problem was resolved in revision F of the Corel products.

Microsoft Publisher and the Microsoft Office programs require version 2.02 of Compobj.dll and Storage.dll, which Windows 95 installs.

RESOLUTION

Restore the newer versions of Compobj.dll and Storage.dll. The steps below assume that your copy of Windows 95 is installed to a folder called C:\Windows. If your copy of Windows 95 is installed to a different folder name or to a different drive, substitute the correct name and drive letter.

  1. Check to see if you have the following folder on your drive:

          C:\Windows\Sysbckup
    

    This folder contains backup copies of several important Windows files. The versions of Windows 95 that comes pre-installed on some computers does not have this folder. If you do not have this folder, please contact the manufacturer of your computer for instructions on replacing these files.

  2. If you do have a C:\Windows\Sysbckup folder, rename the copies of Compobj.dll and Storage.dll that are in your C:\Windows\System folder to something like Compobj.old and Storage.old.

  3. Restart your computer in MS-DOS mode.

  4. Change to the C:\Windows\Sysbckup folder.

  5. Copy Storage.dll and Compobj.dll to the C:\Windows\System folder.

  6. Restart Windows 95.

Publisher and Office should now run correctly.

REFERENCES

For more information on restarting your computer in MS-DOS mode, see the following article here in the Microsoft Knowledge Base:

   ARTICLE-ID : Q138996
   TITLE      : Description of Restarting Computer in MS-DOS Mode


Additional query words: 3.00 97 4.00 call to undefined dynalink launch
start Office 95 OLE DLLs dlls 8.0 7.0 powerpoint excel word winword
xl word95 word7 xl7 xl95 xl97
Keywords : kberrmsg kbusage kbdta
Version : WINDOWS:3.0,95,97
Platform : WINDOWS
Hardware : x86
Issue type : kbprb


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.