X400: TP4 Stack Not Compatible with WFWG MS-DOS Client

Last reviewed: October 20, 1997
Article ID: Q127728
3.20 MS-DOS kb3rdparty

The information in this article applies to:

  • Microsoft Mail Gateway to X.400, version 3.2

SYMPTOMS

The Microsoft Mail Gateway to X.400 may hang upon startup and display the following:

   Gateway initializing...

CAUSE

The TP4 stack provided by the Microsoft Mail Gateway to X.400 is not compatible with the Windows for Workgroups MS-DOS client drivers.

RESOLUTION

Use the Microsoft LAN Manager version 2.2c drivers with TP4. These drivers are supplied with Windows NT version 3.5 (CD).

MORE INFORMATION

The MS-DOS client drivers use IFSHLP.SYS to load network software. This assumes that the drivers will be loaded when NET START is called.

For the TP4 stack to work properly, it needs to load a Data Link Interface (DLI.DOS) driver in CONFIG.SYS. Then TP4 requires the TP4 stack (TP4.EXE) to get loaded before a NET START.


Additional reference words: 3.20
KBCategory: kb3rdparty
KBSubcategory: MailGWPROFS


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.