CRS: Webadmin Cannot Take a Project Name Containing a Space

Last reviewed: February 9, 1998
Article ID: Q176514
The information in this article applies to:
  • Microsoft Commercial Internet System version 1.0
  • Microsoft Site Server version 2.0

SYMPTOMS

The Content Replication System (CRS) Webadmin cannot start a project name that has a space in it; if the name contains a space, you receive the following error message:

   crpr.pgi (46): error 8004005:unspecified error
   crpr.pgi (46): error 80020005: type mismatch

WORKAROUND

To work around this problem, do either of the following:

  • Do not use a space in the project name.

    -or-

  • Use CRS from a command prompt to start the project, as in the following example:

          CRS startrep "<project_name>" /display
    

    NOTE: The quotation marks around the project name are required.


Additional query words: quote mark fail nmdcrs
Keywords : kbusage CommMisc kbbug1.00 kbbug2.00
Version : WINDOWS:1.0 2.0
Platform : WINDOWS
Issue type : kbprb
Solution Type : kbworkaround


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.