SMS Administrator Err Msg: Socket () failed, 10047

Last reviewed: April 22, 1997
Article ID: Q126158

The information in this article applies to:
  • Microsoft Systems Management Server version 1.0

SYMPTOMS

When you attempt to use Systems Management Server Administrator to remotely control a NetWare client, the following error message appears and remote control is not available for any NetWare clients:

   Socket () failed, 10047

CAUSE

Although remote control of NetWare clients uses IPX sockets, SMS Administrator requires the NetBIOS NWBLINK driver.

MORE INFORMATION

NetBIOS support for NWLINK (NWBLINK) is installed under Windows NT when you install NWLINK. However, if you install a Windows NT service that requires NWLINK, and you have not yet installed NWLINK support, NWBLINK is not installed. This happens when you install Gateway Services for Netware (GSNW) on a Windows NT server.

RESOLUTION

To correct this problem, remove and reinstall NWLINK so that NWBLINK is installed, and then install the other software that depends on NWLINK.


Additional query words: sms prodsms administrators
Keywords : kbnetwork smsadmin
Version : 1.0
Platform : WINDOWS


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: April 22, 1997