GetVersionExA Error in SMS 1.1 Network Monitor for WFWLast reviewed: April 23, 1997Article ID: Q139906 |
The information in this article applies to:
SYMPTOMSAfter installing the Network Monitor for Windows for Workgroups from the Systems Management Server 1.1 CD-ROM and running it, the following error message appears:
Win32s - Error, the procedure entry point "GetVersionExA" could not be located in the Dynamic Link Library "KERNEL32.dll" CAUSEThe new call, GetVersionExA, that was implemented in Windows NT 3.5 and 3.51 is not serviced due to incompatible WIN32S .DLLs that come with the Network Monitor Installation Disks located in the NMEXT directory on the Systems Management Server 1.1 CD-ROM.
WORKAROUNDInstall the older WIN32S .DLLs that support GetVersionExA (dated 7/11/95) after you have installed the Network Monitor Version from the CD-ROM.
STATUSMicrosoft has confirmed this to be a problem in Systems Management Server version 1.1. We will post new information in the Microsoft Knowledge Base as it becomes available.
|
Additional query words: prodsms