SMS: NetworkType Not Updated Upgrading from WFWG to Windows NT

Last reviewed: May 21, 1997
Article ID: Q157832
The information in this article applies to:
  • Microsoft Systems Management Server version 1.2

SYMPTOMS

If you upgrade your NetWare Windows for Workgroups client to Windows NT, and then try to upgrade your Microsoft Systems Management Server Client software by connecting to a supported logon server (Windows NT) and running UPGRADE, the "NetworkType" flag will not be updated.

WORKAROUND

A workaround is to add a /f switch to the upgrade batch file command lines. The /f switch forces an update.

STATUS

Microsoft has confirmed this to be a problem in Microsoft Systems Management Server version 1.2. This problem has been corrected in the latest U.S. Service Pack for Microsoft Systems Management Server version 1.2. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

   S E R V P A C K


Additional query words: 1.20 IPX Novell Netware WFWG Windows client
upgrade
Keywords : kbbug1.20 kbfix1.20.sp1 kbfix1.20.sp2 kbnetwork smssetup kbfixlist
Version : 1.2
Platform : WINDOWS
Resolution Type : kbservicepack


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: May 21, 1997
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.