README.TXT: Patch 51 for SNA Server 2.0Last reviewed: April 23, 1996Article ID: Q118364 |
The information in this article applies to:
The following is the README.TXT file that accompanies SNA Server 2.0 patch 51 (SNA20.P51): Note that this article reflects the text of a static document. Therefore, some of the information in this article may be outdated. For example, as of May 20, 1996, Microsoft no longer maintains support forums on CompuServe.
******************* Beginning of Readme *************************** Product: Microsoft SNA Server for Windows NT v2.0 Update: Patch #51 Status: Confirmed Date: July 14, 1994 Modules updated:
\SYSTEM\IBMDFT.DLL 07/14/94 01:46p 70,144 (2.0.0.148) \SYSTEM\HWSETUP\IBMDFT\IBMDFT.DLL (same file)Bugs fixed: 2255 XPROG 752 using DFT link service when accessing CICSVS This occurs with the DCA IRMA driver or IBM DFT driver, which both use the IBMDFT.DLL link service. Under certain circumstances, the number of data elements was being miscalculated by one byte, causing the driver/link to return extra (bogus) data to flow to the server and 3270 emulator, leading to an XPROG 752 error in the emulator. Update Procedure: - Stop the SNA Server Base (SNABASE) service on the server - Copy the updated IBMDFT.DLL over the existing version in the server's <snaroot>\SYSTEM directory. - Restart SNA Server *********************** End of Readme ******************************* SNA Server 2.0 patches are located on:
|
Additional reference words: prodsna 2.00