MDI DB2 Gateway Reports Open Server ErrorLast reviewed: May 23, 1997Article ID: Q123179 |
The information in this article applies to:
SUMMARYWhen you issue a host query through the Micro DecisionWare DB2 database gateway for Windows NT (running over SNA Server), the gateway may report the following errors:
CAUSEThere is a memory problem (a memory leak) in SQL Server version 4.21 in the DBMSSPXN.DLL file. This problem was fixed in version 4.21a.
RESOLUTIONTo resolve this problem, apply the DBMSSPXN.DLL from SQL Server 4.21a to the computer running the Micro DecisionWare DB2 database gateway for Windows NT. NOTE: While this problem is not related to SNA Server, it is included here to make this information easier to locate.
|
Additional query words: prodsna