Problems Running SNA Server 5250 Applet (Autoconnect Enabled)Last reviewed: November 1, 1995Article ID: Q126546 |
The information in this article applies to:
SYMPTOMSIf you run the SNA Server 2.1 5250 applet, and the 5250 Session/Autoconnect switch is enabled, the following problems can occur:
CAUSEThe SNA Server 5250 applet does not wait long enough for the underlying SNA client module (WNAP) to initialize, and then fails to work properly when WNAP fails to initialize.
RESOLUTIONTo workaround this problem in SNA Server version 2.1, configure WNAP to start before the 5250 applet is started. To do this, add a WNAP.EXE icon to the Windows or Windows for Workgroups Startup group.
STATUSMicrosoft has confirmed this to be a problem in SNA Server version 2.1. This problem was corrected in SNA Server version 2.11.
|
KBCategory: kbnetwork kbbug2.10 kbfix2.11