SYMPTOMS

If an SNA Server X.25 Permanent Virtual Circuit (PVC) connection is configured for incoming calls only, the connection is never established.

CAUSE

The SNA Server Admin program should not allow this type of configuration. Outgoing calls should always be configured for PVC connections.

WORKAROUND

To work around this problem, always configure an X.25 PVC connection to support outgoing calls.

STATUS

Microsoft has confirmed this to be a problem in SNA Server versions 2.0 and 2.1. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.


KBCategory: kbnetwork kbbug2.00 kbbug2.10
KBSubcategory: ntnetserv
Additional reference words: prodsna 2.00 2.10 admin x.25 pvc


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: November 1, 1995
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.