Windows NT Telnet Client Does Not Support SNA Server TN3270Last reviewed: April 17, 1997Article ID: Q138482 |
The information in this article applies to:
SUMMARYThe Windows NT Telnet Client does not support SNA Server TN3270 connectivity.
MORE INFORMATIONThe following TN3270 trace information shows a computer attempting to connect as a VT100 terminal type (The Windows NT Telnet client supports VT100, VT52, DEC-VT52, ANSI, DEC-VT100, VT100). This is not a supported TN3270 server terminal type. Refer to the chart below in this article for a list of currently supported terminal types. 10/19 07:48:45.733 (+ smidgen ) Event=TEV_DataFromClient Thread = 0x00000105 Session = 0x0016B6D0 Socket = 0x0000018C 000000 fffa 1800 7674 3130 30ff f0 !....vt100.. !Here the TN3270 Server is sending a negotiation error back to the client and terminating the session. >10/19 07:48:46.004 (+ smidgen ) Event=TEV_TCPSendIssued Thread = 0x00000105 Session = 0x0016B6D0 Socket = 0x0000018C Number of bytes = 104 000000 0d0a 544e 3332 3730 2053 6572 7669 6365 !..TN3270 Service! 000010 2045 7272 6f72 2035 3131 0d0a 0d0a 5465 ! Error 511....Te! 000020 6c6e 6574 206e 6567 6f74 6961 7469 6f6e !lnet negotiation! 000030 2066 6169 6c75 7265 3a20 2063 6c69 656e ! failure: clien! 000040 7420 6469 6420 6e6f 7420 7365 6e64 2054 !t did not send T! 000050 4e33 3237 3020 7465 726d 696e 616c 2074 !N3270 terminal t! 000060 7970 652e 0d0a 0d0a !ype.....>10/19 07:48:48.006 (+ 2 secs ) Event=TEV_SessionTermination Thread = 0x00000105 Session = 0x0016B6D0 Socket = 0x0000018C Session terminatedTrace files contain records of internal activities on the TN3270 Service. These files describe events leading up to a difficulty and the exact state of the system when the difficulty occurred. Trace files are created when TN3270 Service tracing is enabled and then stored in the TRACES subdirectory of the TN3270 Service root directory with the filename extension TRC. The following table describes the IBM terminal types supported by TN3270 Service.
Terminal Name Primary Model Alternative Model Query Support ------------- ------------- ----------------- ------------- IBM-3275-2 Model2 None NO IBM-3276-2 Model2 None NO IBM-3277-2 Model2 None NO IBM-3278-2 Model2 None NO IBM-3278-2-E Model2 None YES IBM-3279-2 Model2 None YES IBM-3279-2-E Model2 None YES IBM-3276-3 Model2 Model3 NO IBM-3278-3 Model2 Model3 NO IBM-3278-3-E Model2 Model3 YES IBM-3279-3 Model2 Model3 YES IBM-3279-3-E Model2 Model3 YES IBM-3276-4 Model2 Model4 NO IBM-3278-4 Model2 Model4 NO IBM-3278-4-E Model2 Model4 YES IBM-3279-4 Model2 Model4 YES IBM-3279-4-E Model2 Model4 YES IBM-3278-5 Model2 Model5 NO IBM-3278-5-E Model2 Model4 YES IBM-3279-5 Model2 Model4 YES IBM-3279-5-E Model2 Model4 YESFor SNA Server 3.0, there are 2 additional Terminal types supported: IBM-Dynamic IBM-3287-1 (Printing terminal type)
|
Additional query words: prodsna
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |