Downstream Connection Should Default to Incoming Calls

Last reviewed: July 29, 1996
Article ID: Q139423
The information in this article applies to:
  • Microsoft SNA Server for Windows NT, version 2.11

SYMPTOMS

When you configure a Downstream (DSPU) connection in SNA Server Admin, the default Allowed Directions value is Outgoing Calls. However, most users require that the Allowed Directions be set to Incoming Calls, so that the downstream PU can initiate the connection.

RESOLUTION

Microsoft has updated the file <snaroot>\SYSTEM\SNAADMIN.EXE to correct this problem.

STATUS

Microsoft has confirmed this to be a problem in SNA Server for Windows NT. This problem was corrected in the latest SNA Server for Windows NT, 2.11 U.S. Service Pack. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

   S E R V P A C K


KBCategory: kbnetwork kbbug2.11
KBSubcategory: ntnetserv
Additional reference words: prodsna 2.11 x25


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: July 29, 1996
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.