Attachmate Advanced Coax Adapter Fails w/Event 23 Qualifier 11

Last reviewed: July 19, 1996
Article ID: Q148996
The information in this article applies to:
  • Microsoft SNA Server for Windows NT, versions 2.0, 2.1, 2.11, and 2.11.sp1

The Attachmate Advanced Coax Adapter may fail with Event 23, Qualifier 11 (DSR failure) if the hardware resources are not set to the following:

       Base Address: CE000
   I/O Port address: 2D0
                IRQ: 2

These settings must also match on the card using jumper settings. See the Attachmate Coax adapter documentation for details on how to change these settings.

The SNA Server IBM DFT driver must be selected in SNA Server Setup if you use the Attachmate Advanced Coax Adapter, which emulates an IBM 3278/3279 Emulation adapter.


KBCategory: kb3rdparty
KBSubcategory: sna3rdparty
Additional reference words: 2.00 2.10 2.11 2.11.sp1 service pack 1


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.