Compaq Insight Manager may Cause TN3270 Event ID 903Last reviewed: November 5, 1997Article ID: Q161047 |
The information in this article applies to:
SYMPTOMSThe Windows NT Event Viewer Application log of a Windows NT Server running the TN3270 service may show repeated Event ID 903s. The event description is as follows:
Windows API ReadFileEx failed with error code 233L (No process is on the other end of the pipe.) in function TCPRecv. EXPLANATION An unexpected error was encountered on an Windows API call. ACTION Record message and contact technical support.The TNServer traces will show a TN session initiated, but the response, DO TERM TYPE, finds nothing to receive the message.
CAUSEThis can be caused by Compaq Insight Manager's use of the standard TCP/IP (Telnet) port 23.
RESOLUTIONThe TN3270 service can be configured to use a different port by editing the <ntroot>\SYSTEM32\DRIVERS\ETC\SERVICES. For example, to configure the TN3270 service to use Port 24, add the following line and restart the TN3270 service:
telnet 23/tcp tn3270 24/tcp # TN3270 ServiceNOTE: This also requires the TN clients to be configured to use this same port.
|
Additional query words:
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |