"-B" Is Printed at End of TN3270 Print JobLast reviewed: April 17, 1997Article ID: Q162515 |
The information in this article applies to:
SYMPTOMSA hyphen and the letter B (-B) are printed at the end of a TN3270 print job.
CAUSEThe TN3270 Server is sending down a WCC byte to the emulator (with the unlock keyboard byte enabled). This would be appropriate for a display session in order to give the emulator direction to send more data back to the host. However, because this is a printer session, the emulator instead interprets this byte as data and prints it.
RESOLUTIONApply the fix referenced below. A fix was made to the TN3270 Server to not send this byte sequence over printer sessions at the end of the print job.
STATUSMicrosoft has confirmed this to be a problem in SNA Server versions 2.11 and 2.11 Service Pack 1. A supported fix is now available for SNA Server 2.11 SP1, but has not been fully regression-tested and should be applied only to systems experiencing this specific problem. Unless you are severely impacted by this specific problem, Microsoft recommends that you wait for the next Service Pack that contains this fix. Contact Microsoft Technical Support for more information.
|