SLI Libraries Set Wrong RU Size After Unbind(Hold)Last reviewed: April 17, 1997Article ID: Q162592 |
The information in this article applies to:
SYMPTOMSSome 32-bit SLI applications may fail when you try to transfer large amounts of data. Investigation shows that the SNA RUI layer is returning an error code of DATA_TRUNCATED when performing a RUI_READ of more than 256 bytes.
CAUSEThere is a problem the SLI library such that it is not picking up the RU size correctly on successive BINDs. When the SLI library receives a BIND, followed by UNBIND(HOLD) and then a new BIND, the SLI library posts an RUI_READ of 256 bytes, even though 3840 byte RUs were negotiated in the final BIND. So, when an RU arrives on the session which is larger than 256 bytes, the SLI_RECEIVE posted only receives 256 bytes and gets a DATA_TRUCATED error from the underlying RUI libraries and the SLI application only gets the first 256 bytes of the host application message. Following is an illustration of the data flow involved:
SNA Server Host ---------- ---- <------------------- BIND ("NMP" session manager), SLU receive size = "85"(256)BIND +RSP ---------------------------> <logon><---------------------- UNBIND(Hold) UNBIND +RSP ---------------------->
<------------------- BIND (Host SLI application), SLU receive size = "F8" (3840)BIND +RSP -------------------------->
<RUI_READ only reads 256 bytes > RESOLUTIONApply the update to SNA Server 2.11 Service Pack 1 and SNA Server 3.0 that corrects this problem. The updated module is Winsli32.dll. VTAM programmers will be able to work around this problem by configuring their session manager (NMP) to send a BIND to SNA Server that specifies a PLU send size of "F8" (this is set in Byte 11 of the BIND message). NOTE: This is NOT the BTU size, but MAXDATA if configured in the LU definition or RUSIZE if configured in the MODETAB for the LU-LU session (or the NMP host session manager application).
STATUSMicrosoft has confirmed this to be a problem in SNA Server version 2.11 Service Pack 1. A supported fix is now available, but has not been fully regression-tested and should be applied only to systems experiencing this specific problem. Unless you are severely impacted by this specific problem, Microsoft recommends that you wait for the next Service Pack that contains this fix. Contact Microsoft Technical Support for more information.
MORE INFORMATIONThe following is an LUA API trace of a large RUI_READ demonstrating the failure.
SLI ---------------------------------------------- 11:28:10.32 SLI SLI_RECEIVE request SLI ---- Verb Parameter Block at address 0080FD68 ----Data omitted for brevity. In the VCB an lua_max_length of 4K assigned. NOTE: VCB structure is packed.
SLI SLI ---------------------------------------------- 11:28:10.61 SLI SLI_RECEIVE response SLI IN_PROGRESS - OK SLI ---- Verb Parameter Block at address 0080FD68 ----Data omitted for brevity. SLI RUI ---------------------------------------------- 11:28:12.73 RUI RUI_READ response RUI UNSUCCESSFUL - DATA_TRUNCATEDData omitted for brevity. In the VCB the lua_max_length(offset 35(2 byte field)) and lua_data_length(offset 37(2 byte field)) fields have a value of 256 bytes.
RUI |
Additional query words: prodsna