DSPU Reconnect Failure After An OutageLast reviewed: April 17, 1997Article ID: Q163519 |
The information in this article applies to:
SYMPTOMSDownstream physical unit (DSPU) fails to recover its connection to SNA Server after a link failure between the two devices.
CAUSEWhen SNA Server receives a format 3 XID from an incoming DSPU that specifies a secondary link station role without preceding it with a negotiable XID, the SNA Server may cause a SABM(E) to be sent immediately without first sending its own format 3 XID. This causes the DSPU to drop the connection.
RESOLUTIONAn update to SNA Server ensures that SNA Server always sends at least one non-NULL XID.
STATUSMicrosoft has confirmed this to be a problem in SNA Server versions 2.0, 2.1, 2.11 and 2.11 Service Pack 1 (SP1). This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K |
Additional query words: prodsna
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |