Multi-session SLI Program Stops Receiving DataLast reviewed: March 19, 1998Article ID: Q170287 |
The information in this article applies to:
SYMPTOMSIf an SLI program opens multiple sessions, the application may fail to receive error notification on all sessions if a link failure occurs, causing the session to stop responding. This problem was observed in the following scenario:
CAUSEThe SNA Server SLI interface is queuing messages to the RUI interface incorrectly, which could cause outstanding SLI calls to fail to return to the SLI application.
STATUSMicrosoft has confirmed this to be a problem in SNA Server versions 2.11 SP2 and 3.0 SP1. This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C KA supported fix is now available for 2.11 SP2, but has not been fully regression-tested and should be applied only to systems experiencing this specific problem. Unless you are severely impacted by this specific problem, Microsoft recommends that you wait for the next Service Pack that contains this fix. Contact Microsoft Technical Support for more information. Keywords : snalua snaprog snawinnt kbfix3.00.sp2 kbnetwork kbprg Version : 2.11 3.0 Platform : winnt Issue type : kbbug Solution Type : kbfix |
================================================================================
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |