LU Creation Wizard Does Not Accept HEX Data When in HEX ModeLast reviewed: March 19, 1998Article ID: Q171877 |
The information in this article applies to:
SYMPTOMSWhen you use the LU Creation Wizard to create a range of LUs, you can select hexadecimal as the Base setting, but the Wizard will not accept hexadecimal data in the First Extension field.
CAUSESnawiz.dll does not accept hexadecimal data even when the hexadecimal mode is selected.
RESOLUTIONA hotfix to SNA Server for Windows NT, version 3.0 (post SP1) is available to correct this problem.
STATUSMicrosoft has confirmed this to be a problem in SNA Server 3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K Keywords : kbbug3.00 kbbug3.00.sp1 prodsna snamanager kbfix3.00.sp2 kbnetwork Version : 3.0 Platform : winnt Issue type : kbbug Solution Type : kbfix |
================================================================================
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |