Control Unit Image Number Not Available to ESCON Link Service

Last reviewed: February 3, 1998
Article ID: Q178252
The information in this article applies to:
  • Microsoft SNA Server, versions 3.0, 3.0 SP1, 3.0 SP2

SYMPTOMS

When implementing an ESCON channel link service (such as the Polaris ESCON channel link service), SNA Server was not providing the control unit (CU) image number to the link service, which significantly complicates ESCON channel link configuration.

CAUSE

SNA Server was not originally designed to return the control unit image number to the channel link service.

STATUS

Microsoft has confirmed this to be a problem in SNA Server 3.0 (including SP1 and SP2). This feature has been added to SNA Server 3.0 (post SP2) and allows the SNA Server to return the Control Unit image number in dataru[s+24] of the Open(Link) response.

Obtain the following fix or wait for the next SNA Server 3.0 service pack. This fix should have the following timestamp:

   10/27/97  7:29a        192,832 <snaroot>\system\SNACFG.DLL
   10/27/97  7:29a        222,064 <ntroot>\symbols\dll\SNACFG.DBG

A supported fix is now available, but has not been fully regression-tested and should be applied only to systems experiencing this specific problem. Unless you are severely impacted by this specific problem, Microsoft recommends that you wait for the next Service Pack that contains this fix. Contact Microsoft Technical Support for more information.

Note that the ESCON channel link service must be written to recognize the Control Unit image number. Contact your link service vendor to determine if this is the case. If so, to make use of this new feature, the updated SNACFG.DLL must be applied and the configuration file must be resaved using SNA Server Manager.

MORE INFORMATION

The Polaris ESCON link service version 2.14 (with the v1.12 version of the Polaris ESCON configuration DLL) supports the ability to use the Control Unit image number. Here is some additional background describing what the control unit image number is used for:

The control unit image is an ESCON feature. It allows a physical control unit to support up to 16 logical control units. The CU image corresponds to the "CUADD" parameter in the CNTLUNIT IOCP macro or the Logical Address in HCD.

The Polaris ESCON link service supports a maximum of 250 devices over a maximum of 16 CU images. The change to SNA Server makes it easier for customers to configure SNA Server to use ESCON. Currently, in order to allow the customer to use multiple CU images, the customer must configure the link service with the devices they need on each CU image. Then they use the number in the channel address box of the connection to specify an index into a table made from the link service configuration. Here's an example:

Actual configuration:

   CU Image  Base Device Address  Num Devices
      0               20              4
      2               40              2
      3               20              4

Channel addresses to input into SNA Server configuration:

   Channel Address   CU Image - Device Address
        00                  0 - 20
        01                  0 - 21
        02                  0 - 22
        03                  0 - 23
        04                  2 - 41
        05                  2 - 42
        06                  3 - 20
        07                  3 - 21
        08                  3 - 22
        09                  3 - 23

This makes configuration more difficult. With this new feature, customers still must configure the link service as before because the ESCON channel adapter needs to know at initialization (ie. when SNA Server is started) which devices it will be using. But in the connection properties the user can put in address 20 CU image 0 instead of just address 00 and so on.

The link service configuration has a check box which allows the user to choose to use the new method. This is not done automatically. The link service has to be told which of the two methods is in use since the field that contains the CU image was 0 for old version of SNA Server, but 0 is a valid CU image.

Regarding the use of the Polaris ESCON link service, this change will not affect users who don't want or need to change their link service configuration. They will still be able to update the link service and driver to newer version with having to redo any part of their configuration.

Keywords          : kbbug3.00 kbbug3.00.sp1 prodsna snaadmin snachannel snawinnt kbbug3.00.sp2
Version           : WINDOWS:3.0,3.0SP1,3.0SP2
Platform          : WINDOWS
Issue type        : kbbug
Solution Type     : kbfix kbpatch


================================================================================


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.