BUG: AnsiToOem Check Box Does Not Work in 6.0 Transfer Manager

Last reviewed: April 15, 1997
Article ID: Q152980
The information in this article applies to:
  • Microsoft SQL Server, version 6.0
BUG #: 9007 (SQL Server 6.00)

SYMPTOMS

The check box for AnsiToOem in SQL Transfer Manager version 6.0 is not set to the same value as the DB-Library option AutoAnsiToOem. Changing it does not affect the AutoAnsiToOem value.

WORKAROUND

To work around this problem, use the SQL Client Configuration Utility to change the AutoAnsiToOem DB-Library option.

STATUS

Microsoft has confirmed this to be a problem in Microsoft SQL Server version 6.0. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.


Additional query words: SQLXFR.EXE CharToOem OemToChar
Keywords : kbbug6.00 kbusage SSrvGen
Version : 6.0
Platform : WINDOWS


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.