PRB: Control Not Visible or Partially Visible at Design Time

Last reviewed: May 22, 1996
Article ID: Q149434
The information in this article applies to:
  • Standard, Professional, and Enterprise Editions of Microsoft Visual Basic, 16-bit and 32-bit, for Windows, version 4.0

SYMPTOMS

A control added to a form at design time, such as a text box, is no longer visible on that form during design time.

CAUSE

The Left and Top properties of the control are set to a value outside the boundaries of the form or set to a negative number. The SSTab control may also reset these properties to a value outside the boundaries of the form.

RESOLUTION

In the Property windows, click the Object list box and click the control. Check the Left and Top properties to make sure they are the appropriate values. If the control is still not visible, set these values to 0 to place the control in the Top Left corner of the form.


Additional reference words: 4.00 vb4win vb4all
KBCategory: kbprb
KBSubcategory: PrgOther PrgCtrlsStd PrgCtrlsCus




THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.