FIX: Crash on Data Tip After Enum Name Changed

Last reviewed: December 18, 1997
Article ID: Q171530
The information in this article applies to:
  • Microsoft Visual Basic Control Creation, Learning, Professional, and Enterprise Editions for Windows, version 5.0

SYMPTOMS

Checking the Data Tips for an enumerated object in a Standard EXE (the client) after changing the name of the Enum in the ActiveX EXE project (the server) may generate the following error:

   "VB5 has caused an invalid page fault in module <module> at <address>"

CAUSE

An untrapped error occurs within Visual Basic when the referenced type library becomes unavailable after the server is disconnected.

STATUS

Microsoft has confirmed this to be a bug in the Microsoft products listed at the beginning of this article. This bug has been fixed in Visual Studio 97 Service Pack 2.

For more information on the Visual Studio 97 Service Pack 2, please see the following article in the Microsoft Knowledge Base:

   ARTICLE-ID: Q170365
   TITLE     : INFO: Visual Studio 97 Service Packs - What, Where, and Why

For a list of the Visual Basic 5.0 bugs that were fixed in the Visual Studio 97 Service Pack 2, please see the following article in the Microsoft Knowledge Base:

   ARTICLE-ID: Q171554
   TITLE     : INFO: Visual Basic 5.0 Fixes in Visual Studio 97
               Service Pack 2

MORE INFORMATION

Steps to Reproduce Behavior

  1. Create a new ActiveX EXE project in Visual Basic 5.0.

  2. Place the following code in Class1:

          Enum Test
    
            xxx
            yyy
          End Enum
    
    

  3. In the Project Properties Window, change the name of the project to “ProjectTest.”

  4. Run the ActiveX EXE.

  5. Launch another instance of Visual Basic 5.0.

  6. Create a new Standard EXE project.

  7. Select Project...References and set a reference to ProjectTest.

  8. Select Project...Add Module to create a new module.

  9. Place the following code in Module1:

          Sub Main()
            Dim a as Test
            a = xxx
            Stop
          End Sub
    
    

  10. Select Project...Project1 Properties and set the startup object to
       Sub Main.
    
    

  11. Run the client (Project1).

  12. At the Stop statement, select the instance of Visual Basic where the server is running.

  13. Stop the server from running.

  14. Modify the Enum name to be “Test2.”

  15. Run the server.

  16. Select the instance of Visual Basic where the client is running.

  17. Move the mouse over the “xxx” to view the Data Tip. This generates an invalid page fault in Visual Basic.
Keywords          : vb5all VS97FixlistSP3 VS97FixlistSP2 VB5FixlistSP2
Version           : 5.0
Platform          : WINDOWS
Issue type        : kbbug
Solution Type     : kbfix kbservicepack


================================================================================


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: December 18, 1997
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.