The information in this article applies to:
- Microsoft Visual Basic Control Creation, Learning, Professional, and
Enterprise Editions for Windows, version 5.0
SYMPTOMS
When attempting to raise a remote event across Remote Automation, the
following run-time error appears:
-2147467259(80004005) , Automation error
CAUSE
Remote Automation does not currently support the use of WithEvents.
RESOLUTION
To support remote events with Visual Basic 5.0, use DCOM instead of Remote
Automation. You can also use callbacks to simulate raising events remotely.
STATUS
This behavior is by design.
MORE INFORMATION
Steps to Reproduce Behavior
Use the following steps on the server machine:
- Start Visual Basic 5.0 and create a new ActiveX EXE project.
- From the Project menu, selectProject properties and change the Project
name to "Projtest."
- Add a Class Module and change its name to "Testclass."
- In Testclass' Code window, input following code:
Public Event propchange(newv As String)
Private propt As String
Public Sub showfrm()
MsgBox "asdfl"
End Sub
Public Property Get testp() As String
testp = propt
End Property
Public Property Let testp(ByVal vNewValue As String)
propt = vNewValue
RaiseEvent propchange(propt)
End Property
- On the File menu, click "Make ProjTest.exe."
- Copy the corresponding .exe, .tlb, and .vbr files to the client machine.
- Start the Automation Manager and the RemAuto Connection Manager to set
necessary server-side configuration for using Projtest.testclass for
Remote Automation.
Use the following steps on the client machine:
- Run Projtest.exe, which was copied from the Server side in the above
steps.
- Start the RemAuto Connection Manager to set necessary Client-side
configuration for using Projtest.testclass.
- Launch Visual Basic 5.0 and create a new Standard EXE project with a
standard form.
- From the Project menu, click References and select the "Projtest" box.
- In Form1's Code window, input following code:
Public WithEvents eventp As testclass
Private Sub eventp_propchange(newv As String)
MsgBox newv
End Sub
Private Sub Form_Load()
Dim a As New testclass
a.showfrm
Set eventp = a
a.testp = "test string"
End Sub
- Run the project and check if the Remote Automation connection is
correct, the message box should pop up on the server-side machine.
- Click OK to close the message box on the server-side machine.
Result
When the line "Set eventp = a" executes, you will get the following run-
time error:
-2147467259(80004005) , Automation error
Expected behavior
A message box should appear on the client-side machine because the server
raised the Propchange event.
NOTE: If both the client and the server are running on the same machine
(with local automation), you will see the expected behavior.
Keywords : VBKBDAO VBKBDB VBKBJet VBKBObj
Version : WINDOWS:5.0
Platform : WINDOWS
Issue type : kbprb