HOWTO: Debug an Active Process in 32-bit Visual C++

Last reviewed: October 7, 1997
Article ID: Q120707
The information in this article applies to:
  • The Integrated Debugger included with: Microsoft Visual C++ 32-bit Edition, version 2.0, 2.1, 4.0, 4.1, 5.0

SUMMARY

You can debug an active process with Microsoft Visual C++ versions 2.x, 4.x, and 5.0. You can attach to the active process by starting Visual C++ using the undocumented -p switch, followed by the process identification number (PID).

MORE INFORMATION

To obtain the PID for the process to be debugged, use the process viewer (PVIEW.EXE). Start PView. You will see something like this:

   Process               CPU Time      Privileged      User
   MyApp(0xb7)           ...

Here 0xb7 is the PID value of the application named MyApp.

Assume that the process was built with debugging information. Start Visual C++ version 2.x as follows:

   MSVC -p 0xb7

Or, start Visual C++ version 4.x and 5.0 as follows:

   MSDEV -p 0xb7

NOTE: With VC5.0, you can also attach to a process by selecting the following menu option:

   Build::Start Debug::Attach to Process...

When Visual C++ is loaded, look for statements in the status bar at the bottom of the screen stating that symbols for the application and its DLLs have been loaded. At this point, select the Debug menu, and choose the Break option to see the assembler listing in the main window. Bring up the call stack. Then double-click one of your functions. This brings up the source code for that source module in which a breakpoint can be set, or you can just open a source file and set a break point.

NOTE: When you stop debugging the application, the application will be terminated. This is expected behavior.

The procedure on Windows 95 is a little different with Visual C++ 2.0 through 4.0 (Visual C++ 4.1 handles the Windows 95 PID without conversion). The Windows 95 PIDs are negative signed decimals when converted from hexadecimal. You need to make sure the PID has a minus sign in front of it. For instance, if the PID of the process you want to attach to is FFFE64C3, you can use this method with calculator to get the PID:

   Hex PID -> [Not] -> (DEC) -> [Not] -> Dec PID

The double negation is to trick calculator into giving you the correct number. Otherwise, it gives you the unsigned decimal equivalent of the hex number, which is well outside the valid PID range. In this example, you should get a Dec PID of -105277. The command line to attach, then, is simply:

   start msdev -p -105277 -e -105277

If you pass an invalid PID, you might receive an error like:

   Invalid Parameter (Win32, Error 87)


Additional query words: current running attach
Keywords : WBDebug
Version : WINNT:2.0,2.1,4.0,4.1,5.0;
Platform : NT WINDOWS
Issue type : kbhowto


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.