FIX: Sample Application Dialog Box Is Disabled in InfoViewer

Last reviewed: September 18, 1997
Article ID: Q140088
4.00 WINDOWS NT kbtool kbbuglist kbfixlist

The information in this article applies to:

  • The development environment included with:

        - Microsoft Visual C++, 32-bit Edition, version 4.0
        - Microsoft FORTRAN PowerStation 32 for Windows NT, version 4.0
    

SYMPTOMS

In the InfoViewer, when looking at the sample documentation, the button labeled "Click to open or copy the XXX project files" may be disabled. This button normally brings up the Sample Application dialog box to get the sample code.

In some samples, the button is labeled STEP1, STEP2, STEP3, and so on.

CAUSE

If you press ALT+F4 or an equivalent key combination to close the dialog box the first time it comes up, it doesn't close correctly. Even though the dialog box is no longer visible, it isn't actually dismissed and can still be seen in Spy++. It will have a title similar to this one:

   Window 004601D0 "Sample Application" #32770 (Dialog)

Because the dialog box isn't actually gone, clicking the button can't restore it.

RESOLUTION

To work around the problem and gain access to the sample files, press the ESC key and try again, or exit and then restart the Developer Studio.

STATUS

Microsoft has confirmed this to be a bug in the Microsoft products listed at the beginning of this article. This bug was corrected in Visual C++ 4.1.

MORE INFORMATION

Steps to Reproduce Problem

  1. From the InfoView in the Workspace window, open one of the samples such as:

    CUSTOMWZ: A Custom AppWizard

  2. Click the button labeled "Click to open or copy the CUSTOMWZ project files." This will bring up the Sample Application dialog box, which will allow you to select and open any of the files for the sample.

  3. Dismiss the Sample Application dialog box by pressing ALT+F4, by double-clicking the control-menu box in the upper-left corner, or by clicking the X in the upper-right corner of the window in Windows 95.

  4. Click the button labeled "Click to open or copy the CUSTOMWZ project files" again. This will do nothing.

  5. Start Spy++, and look for the Sample Application dialog window. It will be there even though it should not (because it was 'closed').

  6. Back in InfoView, select a different sample. Bring up the Sample Application dialog box, and close it by pressing the ESC key or by clicking the Close button on the dialog box. This time the Sample Application dialog box will close properly, so it can be re-opened.


Additional reference words: 4.00 4.10 utilities
KBCategory: kbtool kbbuglist kbfixlist
KBSubcategory: VWBIss vcbuglist400 vcfixlist410
Keywords : vcbuglist400 vcfixlist410 VwbIss kbbuglist kbfixlist kbtool
Version : 4.00
Platform : NT WINDOWS
Solution Type : kbfix


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: September 18, 1997