WFWG Err Msg: STOP! You Must Type a Full Path Including...

Last reviewed: January 11, 1995
Article ID: Q101285
The information in this article applies to:
  • Microsoft Windows for Workgroups versions 3.1, 3.11

SYMPTOMS

If you try to share a local printer, you may receive the following error message:

   STOP!  you must type a full path including a drive letter

CAUSE

This error occurs when the TEMP environment variable is set to a directory that does not exist.

WORKAROUND

To correct this situation:

  1. Edit the AUTOEXEC.BAT file with a text editor, such as Microsoft Windows Notepad. Ensure the SET TEMP statement is similar to the following:

          SET TEMP=C:\WINDOWS\TEMP
    

  2. Run File Manager and ensure there is a C:\WINDOWS\TEMP directory. If there is not, choose Create Directory from the File menu and create C:\WINDOWS\TEMP.

  3. If you changed your AUTOEXEC.BAT file in step 1, you need to exit Windows for Workgroups and restart your computer.


KBCategory: kbprint kbnetwork kberrmsg kbusage
KBSubcategory: wfw wfwg
Additional reference words: 3.10 3.1 3.11


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.