NETWORKS.WRI from Windows for Workgroups 3.11 (Part 1 of 4)

Last reviewed: November 21, 1994
Article ID: Q109503
The information in this article applies to:
  • Microsoft Windows for Workgroups version 3.11

SUMMARY

The following information was taken from the Microsoft Windows for Workgroups version 3.11 NETWORKS.WRI file.

MORE INFORMATION

Additional Notes About Networks _______________________________________________

This document contains information about specific networks. For additional information about Windows for Workgroups that does not pertain to networks, see "Other Online Documents" at the end of this document.

Contents

This document contains information about the following topics:

1.0 General Notes 2.0 Using Novell NetWare 2.1 Setting Up Novell NetWare to Work with Windows for Workgroups 3.11 2.2 More Information about Using Novell NetWare with Windows for

     Workgroups 3.11
2.3 Changes to System Files
      2.3.1 IPXODI.COM and LSL.COM support over Ethernet
            or Token Ring Networks
      2.3.4 IPX/SPX Support
      2.3.3 IPXODI.COM and LSL.COM support over an ArcNet
            Network
      2.3.4 IPX/SPX Support with an ArcNet Network

3.0 Using Banyan VINES 3.1 Changes to System Files when You Install Support for Banyan VINES 3.2 Special Information about Specific Versions of VINES 3.3 Banyan VINES Troubleshooting Tips

4.0 Using Windows for Workgroups 3.11 with DEC PATHWORKS 4.1 Changes to System Files when You Install Support for DEC

    PATHWORKS Instead of the Microsoft Windows Network
4.2 Changes to System Files when You Install Support for DEC
    PATHWORKS along with the Microsoft Windows Network

5.0 Using Windows for Workgroups 3.11 with Artisoft LANtastic 5.1 Changes to System Files When You Install Artisoft LANtastic Drivers 5.2 Changes to System Files When You Install Support for Artisoft LANtastic 5.3 More Information about Using Artisoft LANtastic with Windows for
    Workgroups 3.11

6.0 Using Windows for Workgroups 3.11 with SunSelect PC-NFS 6.1 Changes to System Files When You Install Support for PC-NFS

7.0 Using Windows for Workgroups 3.11 with Beame & Whiteside BW-NFS

8.0 Using Windows for Workgroups 3.11 with ArcNet

9.0 Using Windows for Workgroups 3.11 with TCP/IP 9.1 Changes to System Files When You Install TCP/IP 9.2 Sample PROTOCOL.INI file 9.3 More Information about using Windows for Workgroups 3.11 with TCP/IP

10.0 Using Windows for Workgroups 3.11 with Data Link Control (DLC)

     Protocol
10.1 Changes to System Files When You Install MS-DLC 10.2 Sample PROTOCOL.INI file

11.0 Using Windows for Workgroups 3.11 with MS-Net Compatible Networks

12.0 Using an Unlisted Network Adapter with No OEMSETUP.INF File

13.0 Other Online Documents

MS-DOS is a registered trademark and Windows is a trademark of Microsoft Corporation.

3+Share is a registered trademark of 3Com Corporation. Artisoft and LANtastic are registered trademarks of Artisoft, Inc. Banyan and VINES are registered trademarks of Banyan Systems, Inc. BW-NFS is a registered trademark of Beame & Whiteside Software, Inc. ArcNet is a registered trademark of Datapoint Corporation. DEC is a registered trademark and PATHWORKS is a trademark of Digital Equipment Corporation. TCS is a registered trademark of Eurotherm International P.L.C. NetWare and Novell are registered trademarks of Novell, Inc. 386MAX is a registered trademark of Qualitas, Inc. Qemm is a trademark of Quarterdeck Office Systems. PC-NFS is a registered trademark and SunSelect is a trademark of Sun Microsystems, Incorporated. Net/One and Ungermann-Bass are registered trademarks of Ungermann-Bass, Inc.

1.0 General Notes

  • Many settings in the SYSTEM.INI file affect the way Windows for Workgroups works. You can change these settings to correct most problems you might have while you are using Windows for Workgroups and other networks. See the SYSINI.WRI online document for information about changing the following SYSTEM.INI settings:

[Boot] Network.drv= SecondNet.drv=

[386Enh] 32BitAccess= AllVMsExclusive= EMMExclude= FileSysChange= InDOSPolling= Int28Critical= NetAsyncFallback= NetAsyncTimeout= NetCard= NetDMASize= NetHeapSize= NetMisc= Network= ReflectDOSInt2A= SecondNet= TimerCriticalSection= Transport= TokenRingSearch= V86ModeLANAs= UniqueDOSPSP=

[network] EnableSharing= Exclude= FileSharing= LANAs= LogonValidated= Multinet= PrintSharing= Reshare=

  • The Windows for Workgroups Setup program places the following lines in your SYSTEM.INI file that are required for Windows for Workgroups to run correctly. Do not remove any of the following entries:

[boot] network.drv=wfwnet.drv

[386Enh] network=*vnetbios,vnetsup.386,vredir.386,vserver.386,*vwc

If you have upgraded over a previous version of Windows 3.1 or Windows for Workgroups 3.1 with an installed network, Setup may leave unnecessary files, causing performance problems or incorrect network behavior. If you experience network problems and have any of these lines in your SYSTEM.INI file (or WIN.INI file), try removing the lines to see if the problem can be corrected.

In the SYSTEM.INI file:

[386Enh] INDOSPolling=TRUE EMMExclude=D800-DFFF (or other memory range) TimerCriticalSection=5000 (or other value) UniqueDOSPSP=TRUE PSPIncrement=5 NetHeapSize=76 (or other value) NetAsynchTimeout=50 NetAsynchFallback=true PerVMFiles=0 OverlappedIO=off

In the WIN.INI file:

load=winpopup.exe load=nwpopup.exe

[ports] LPT1.DOS= LPT2.DOS= LPT3.DOS=

  • Many protocols and other networks require the TimerCriticalSection line in the [386Enh] section of the SYSTEM.INI file to be set to a value of 10000 or greater. For more information, see the SYSINI.WRI online document.
  • The default value for the NetHeapSize line in the [386Enh] section of the SYSTEM.INI file is 16K. Although some applications require this value, in most cases you can decrease the value to 4K in order to increase the amount of memory available to your applications. A few applications require the value to be 4K.
  • If you want to change your network configuration, use Windows Setup to make the changes.
  • Some network adapters require the EMMExclude line in the [386Enh] section of the SYSTEM.INI file to be set to the memory range used by the adapter. For more information, see your network-adapter documentation and the SYSINI.WRI online document.

    These cards may also require an x= option on the EMM386 command line in your CONFIG.SYS file. For more information, see Appendix C, "Troubleshooting," in the Microsoft Workgroup Add-On "User's Guide." If you are using 386Max, QEMM, or another memory manager, see your memory-manager documentation to find out whether you need to exclude this area.

  • The Windows for Workgroups 3.11 Resource Kit contains additional information about setting up and configuring Windows for Workgroups for use with other networks and information for system administrators. This kit provides complete technical information about Windows for Workgroups for the support professional. It includes a technical reference manual and a disk containing helpful utilities, drivers, and accessories.

    If you currently own the Windows for Workgroups 3.1 Resource Kit, an addendum is available. It provides information about the new features and enhancements available in Windows for Workgroups 3.11.

    To order the Windows for Workgroups 3.11 Resource Kit or the Windows for Workgroups Resource Kit Addendum for Version 3.11 within the United States, dial:

    1-800-642-7676

    To order outside of the United States, dial the phone number for your area. You can find this number on the International Subsidiary card.

  • If you are running a shared copy of Windows for Workgroups from a network drive, make sure both your personal Windows directory and the shared network directory are included on the path command line in your AUTOEXEC.BAT file. To run a shared copy of Windows for Workgroups, you must start the network before starting Windows for Workgroups. (When you start the network before you start Windows for Workgroups, about 100K less conventional memory is available.)
  • If you used setup /n to set up a shared copy of Windows for Workgroups and you specified a network directory for your personal Windows directory, you cannot start the network (real-mode redirector) before you start Windows for Workgroups unless you first copy your SYSTEM.INI file to the directory on your hard disk where NET.EXE is located. NET.EXE should be located in the root directory of your startup drive.

    Also, if you used setup /n to set up your shared copy of Windows for Workgroups over a Windows NT or LAN Manager network, you will not be able to share your files or printers. This is because you need to Microsoft Windows Network by using the real-mode redirector, and you cannot share files or printers with the real-mode redirector. For more information, see the Windows for Workgroups 3.11 Resource Kit.

  • If you receive sharing violations while running a shared copy of Windows for Workgroups, make sure that all of the files in the shared network directory are marked as read-only.
  • The NetBEUI protocol is the only protocol included with Windows for Workgroups that can be used with the Microsoft Windows Network from the DOS prompt. All others can be used only while Windows for Workgroups is running. If you will be using the Microsoft Windows Network from the DOS prompt, make sure the NetBEUI protocol is one of the protocols you are using.
  • Windows Print Manager spools print jobs to the location specified by the MS-DOS environment variable TEMP. If the TEMP variable is not set, Print Manager will use the root of drive C. The TEMP variable may be set by placing a set temp= statement in your AUTOEXEC.BAT file or network login script. For example, to spool to the network directory C:\WINDOWS\TEMP, you would use the statement set temp=c:\windows\temp. Each user must have a personal TEMP directory.

2.0 Using Novell NetWare

For information about setting up Novell NetWare support in Windows for Workgroups, see Chapter 9, "Using Other Networks," in the Microsoft Workgroup Add-On "User's Guide."

Windows for Workgroups 3.11 supports NDIS, IPX, and ODI network-adapter drivers.

If you are upgrading from Windows for Workgroups 3.1 and you were using the MSIPX drivers that were included with Windows for Workgroups 3.1, you should use either the IPX.COM driver or the IPXODI.COM driver supplied by Novell. We recommend that you use IPXODI.COM. To do this, see the following section, "Setting up Novell NetWare to Work With Windows for Workgroups 3.11."

Once you have set up Novell NetWare to work with either the IPX.COM driver or the IPXODI.COM driver, remove NetWare support from Windows for Workgroups. Then reinstall NetWare support. This will give you the option to choose either IPX.COM or IPXODI.COM.

2.1 Setting Up Novell NetWare to Work with Windows for Workgroups 3.11

We recommend that you set up Novell NetWare to work with the IPXODI.COM driver. However, the IPX.COM monolithic driver is also supported.

Note: If you are using IPXODI.COM, you must make sure that your copies of IPXODI.COM and LSL.COM are versions 1.20 or higher. Otherwise, Windows for Workgroups will not be able to run.

To set up Novell NetWare on your computer:

  1. If you are setting up Novell NetWare version 4.0 or higher, add the following line to your CONFIG.SYS file:

          lastdrive=z
    

    Otherwise, add the line lastdrive=p. This will make your login drive Q:

  2. If you are installing Novell NetWare to work with IPXODI.COM, add the following lines to your AUTOEXEC.BAT file:

          cd c:\<NetWare directory>
          lsl
          <appropriate ODI driver for your network card>
          ipxodi
          netx /ps=<preferred server name>
          q:login <username>
    

        If you are installing Novell NetWare to work with IPX.COM, add the
        following lines to your AUTOEXEC.BAT file.
    

           ipx
           netx /ps=<preferred server name>
           q:login <username>
    

  3. Add the name of your NetWare directory to the PATH line in your AUTOEXEC.BAT file.

  4. Create a NET.CFG file in your NetWare directory. See your NetWare documentation for information on how to do this.

    This is a sample NET.CFG file:

    Link Driver EXP16ODI

            Frame Ethernet_802.3
            Frame Ethernet_II
            Frame Ethernet_802.2
            Frame Ethernet_SNAP
            port 300
            int 5
    
    

  5. Restart your computer. Once you are able to log on to your preferred server successfully, you can set up Windows for Workgroups to work with NetWare. See the Microsoft Workgroup Add-On "User's Guide" for more information.


KBCategory: kbnetwork kb3rdparty kbref
KBSubcategory:
Additional reference words: wfw wfwg 3.11


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: November 21, 1994
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.