SETUP.TXT from Windows for Workgroups 3.11 (Part 2 of 3)Last reviewed: May 1, 1997Article ID: Q109511 |
3.11
WINDOWS
kbref kbdisplay
The information in this article applies to:
SUMMARYThe following information was taken from the Microsoft Windows for Workgroups version 3.11 SETUP.TXT file.
MORE INFORMATION
Setting Up an XGA Video Adapter on a PS/2(R) Model 75 or 90If you have a PS/2 model 75 or 90 with an XGA video adapter, Windows for Workgroups Setup will configure the display adapter for 16-color, 640x480 resolution. Do not change this configuration during Setup. Specifying a different XGA configuration while setting up Windows for Workgroups may cause Setup to fail. After you have successfully installed Windows, you can configure your XGA to use a different resolution or 256 colors, if your monitor supports it. For more information on how to do this, see the topic "IBM XGA: Configuring Color and Resolution" in the README.WRI online document. If you are using the plasma screen on the PS/2 model 75, use ONLY the 640x480, 16-color configuration. If you change this configuration, you return to the MS-DOS prompt when you try to start Windows.
Setting up an IBM Token Ring 4/16Mbs Network Card on a Microchannel (MCA) Computer If you have a Microchannel computer, and you are installing Windows for Workgroups support for the IBM Token Ring 4/16Mbs network card, you must make sure the Maximum Transmits parameter is set no higher than 1024. If you try to use a higher value, the network card will not work with your computer.
Correcting the "Out of Environment Space" Error MessageIf you receive an "out of environment space" message when starting Windows, you can solve the problem in either of two ways:
Using Multimedia Extensions Version 1.0 with Windows for WorkgroupsTo use the Multimedia Extensions with Windows for Workgroups, first set up Windows with Multimedia Extensions version 1.0. Then upgrade to Windows for Workgroups by installing it into the same directory. If you set up Windows for Workgroups before setting up Multimedia Extensions, not all the files will be properly installed. See the README.WRI online document for more information about running Multimedia Extensions with Windows for Workgroups.
Getting Drivers from the Windows Driver Library (WDL)The Microsoft Windows Driver Library (WDL) is available on online services. For more information about the WDL, see the following articles in the Microsoft Knowledge Base.
ARTICLE-ID: Q135314 TITLE : Windows 95 Driver Library ARTICLE-ID: Q82006 TITLE : Windows Driver Library InformationTo use MSDL, use the following communications settings:
Bit rate 1200, 2400, or 9600 bits per second (BPS) Data bits 8 Parity None Stop bits 1People within the United States who do not have a modem can order individual files on disks from the Windows Driver Library by calling Microsoft Product Support Services at (425) 637-7098 or (425) 635-4948 (text telephone).
USING TERMINATE-AND-STAY-RESIDENT (TSR) PROGRAMS AND DRIVERS WITH WINDOWS FOR WORKGROUPS The "Program Listing" section of this document lists a number of terminate- and-stay-resident (TSR) programs and drivers that are known to cause problems when running with Windows for Workgroups. Some of the problems you may encounter include system failures or incorrect screen displays. In some cases, we have included solutions or workarounds for the problems. When you install Windows for Workgroups, Setup searches your AUTOEXEC.BAT and CONFIG.SYS files for references to TSR programs and drivers and scans memory for TSRs that are currently running. If Setup detects a TSR that is known to cause problems when running with Windows for Workgroups, a message appears asking whether you want to continue or quit Setup. If you receive such a message, carry out the following procedure:
Setup cannot detect all the TSRs or drivers included in the "Program Listing" section. The TSRs and drivers that Setup can detect are listed in the in the [incomptsr1] and [incomptsr2] sections of the SETUP.INF file.
PROGRAM LISTINGThis section describes some problems that you might encounter while using a TSR with Windows for Workgroups. It does not include all possible problems that can occur.
386MAX(R)The documentation for 386MAX recommends against setting the EXT parameter below 64. If you set this parameter to 0, Setup will fail. See the README.WRI online document for more information about running 386MAX with Windows for Workgroups.
386MAX Disk-Cache Utility (QCACHE.EXE)Do not use this disk-cache utility simultaneously with SMARTDrive. There is no reason to use two disk-cache utilities with Windows for Workgroups. It is recommended that you use SMARTDrive, provided with Windows for Workgroups, instead.
All Charge 386 Version 3.1ALLEMM4.SYS is a memory manager that causes problems with Setup and Windows for Workgroups. If you encounter problems running this program with Windows for Workgroups, it is recommended that you use EMM386.EXE and HIMEM.SYS, provided with Windows for Workgroups, to manage memory instead.
Anarkey Version 4.00Do not run Windows for Workgroups when Anarkey version 4.00 is running. With some memory configurations, running Anarkey version 4.00 with Windows for Workgroups may cause unpredictable system failures. In rare cases, this program can also corrupt hard-disk data. Also, Windows for Workgroups might not start when this program is running. Version 4.01 may correct these problems. Contact Moderne Software for a free upgrade to Anarkey 4.01.
Anarkey Version 4.01Do not load Anarkey HIGH before starting Windows for Workgroups. If you load Anarkey HIGH, your system may fail when you try to start an application.
APPEND (MS-DOS)Do not use the APPEND utility with Windows for Workgroups. It prevents Windows and Windows-based applications from creating valid Well-Formed-Path (WFP) names for the files they are using. (A WFP is the complete name of a file, including the drive letter and full path specification, starting from the root directory.)
ASP Integrity Toolkit Version 3.7This virus-protection program can cause problems when you are running Windows for Workgroups Setup, including system failure, automatic restarting of the system, and keyboard failure. You should turn off protection in the Toolkit before you set up Windows for Workgroups. For information about how to do this, see your ASP Integrity documentation.
Autocon Version 2.0eAutocon enables you to select up to 50 different configurations when you start your system. To do this, it modifies your CONFIG.SYS and AUTOEXEC.BAT files, based on information in its database (AUTOCON.DAT), when you restart your system from within Autocon. Windows for Workgroups Setup modifies only the first section in your CONFIG.SYS and AUTOEXEC.BAT files. If you want to use specific configurations with Windows, you must run Autocon and then manually edit the configurations in the database that you want to use. You must do this after setting up Windows for Workgroups. For your changes to take effect, you must restart your system from within Autocon. For more information, see your Autocon documentation.
Bootcon Version 1.60Bootcon enables you to maintain different system-configuration information in your CONFIG.SYS and AUTOEXEC.BAT files. You can then select the configuration you want to use from a menu when you start your system. Setup modifies the first section in your CONFIG.SYS and AUTOEXEC.BAT files and may modify certain other sections that contain network drivers (for example, LAN Manager drivers and NetWare drivers may be deleted). After you set up Windows for Workgroups, you must edit the sections of those files that contain other configurations you want to use. For more information, see your Bootcon documentation.
BOOT.SYSBOOT.SYS enables you to maintain different system-configuration information in your CONFIG.SYS and AUTOEXEC.BAT files. You can then select the configuration you want to use from a menu when you start your system. Setup modifies the first section in your CONFIG.SYS and AUTOEXEC.BAT files and may modify certain other sections that contain network drivers (for example, LAN Manager drivers and NetWare drivers may be deleted). After you set up Windows for Workgroups, you must edit the sections of those files that contain other configurations you want to use. For more information, see your BOOT.SYS documentation.
CACHE.EXE Disk-Cache UtilityDo not use two disk-cache utilities with Windows for Workgroups. It is recommended that you use SMARTDrive, provided with Windows for Workgroups, and remove all references to other disk-cache utilities from your CONFIG.SYS and AUTOEXEC.BAT files. (If CACHE.EXE is detected, Setup removes it from your CONFIG.SYS file for you.)
CACHE.SYS Disk-Cache UtilityThis disk-cache utility will not work properly with SMARTDrive. It is recommended that you use SMARTDrive, provided with Windows for Workgroups, and remove all references to other disk-cache utilities from your CONFIG.SYS and AUTOEXEC.BAT files. (If CACHE.SYS is detected, Setup removes it from your CONFIG.SYS file for you.)
CED Version 1.0eUsing CED with Windows for Workgroups may cause problems, including system failure. It is recommended that you do not use CED with Windows for Workgroups.
Central Point Anti-Virus Version 1.1 (VSAFE.COM/VSAFE.SYS)VSAFE.COM/VSAFE.SYS should not be loaded when you set up Windows for Workgroups. Otherwise, Setup may not run properly. After you set up Windows for Workgroups, you can load VSAFE. If you are upgrading to Windows for Workgroups 3.11, you must also delete all the CHKLIST.MS files that VSAFE has created before you run Setup. Because Windows uses the disk for memory swapping, you should turn off the VSAFE write-protection option when you run Windows for Workgroups. For more information, see the Central Point Anti-Virus documentation.
CMDEDIT.COM Version 2.0If this command-line editor is loaded before Windows for Workgroups is started, it may cause a General Protection Fault when you run multiple MS- DOS Prompts.
Cubit Version 3.01When you are using Cubit with Windows for Workgroups, do not compress the Windows SYSTEM directory or any file that is loaded from your CONFIG.SYS file. Compressing these files could cause problems. Before you upgrade to Windows for Workgroups, make sure that the earlier version of Windows is uncompressed on your hard disk. You may recompress the files after you have successfully set up Windows for Workgroups.
Data Physician Plus Version 2.0 (VirALERT)It is recommended that you do not set up Windows for Workgroups while VirALERT is running. If you do, VirALERT will display a warning message every few seconds while Setup is running. After you have set up Windows for Workgroups, you can run VirALERT. Press ALT+V to display the VirALERT menu. You can use the commands on this menu to disable and enable VirALERT.
DOSCUE.COM Command-Line EditorThe DOSCUE command-line editor produces unexpected results when used with Windows for Workgroups. It is recommended that you do not use this editor with Windows for Workgroups.
Doubledisk Version 2.5Windows for Workgroups may try to access "phantom" disk drives if you use it with Doubledisk. Phantom drives occur when you use Doubledisk to create a compressed drive. For example, if you have drives A, B, and C on your computer and you use Doubledisk to create drive F, Windows for Workgroups and MS-DOS recognize drives D and E as valid drives, even though they do not actually exist. You can use the DRVOFF utility to prevent Windows from recognizing phantom drives. Contact Vertisoft to order a copy of the DRVOFF utility.
Fastopen (MS-DOS)Fastopen is a RAM-resident utility. Problems involving the file allocation table (FAT) may occur if Fastopen is used with disk-defragmenting utilities. In low-memory situations, you may need to remove Fastopen for Windows for Workgroups to run properly.
Flash Disk-Cache Utility (FLASH.EXE)Do not use this disk-cache utility simultaneously with SMARTDrive. There is no reason to use two disk-cache utilities with Windows for Workgroups. It is recommended that you use SMARTDrive, provided with Windows for Workgroups, instead.
Graphics (MS-DOS)Loading Graphics from MS-DOS Prompt within Windows can cause unexpected results when you are printing. The active MS-DOS Prompt will send its output to the printer. Switching between multiple MS-DOS Prompts may result in mixed printing jobs.
HPEMM386.SYS and HPEMM486.SYSThese expanded-memory managers are incompatible with Windows for Workgroups. It is recommended that you use EMM386.EXE to manage memory instead.
HPMM.SYS - HP Memory ManagerWhen HPMM.SYS is running, you cannot set up Windows for Workgroups. You should remove all references to HPMM.SYS from your CONFIG.SYS and AUTOEXEC.BAT files before setting up Windows for Workgroups.
Hyperdisk Disk-Cache UtilityDo not use this disk-cache utility simultaneously with SMARTDrive. There is no reason to use two disk-cache utilities with Windows for Workgroups. It is recommended that you use SMARTDrive, provided with Windows for Workgroups, instead.
IBM VDISK.SYS (RAM Disk Utility)VDISK.SYS is incompatible with Windows for Workgroups because it occupies extended memory required to run Windows for Workgroups. This utility prevents any XMS-compatible memory manager from loading.
IEMM.SYS Memory ManagerThe IEMM.SYS memory manager is incompatible with Windows for Workgroups. It is recommended that you remove all references to IEMM.SYS from your CONFIG.SYS and AUTOEXEC.BAT files and use EMM386.EXE, provided with Windows for Workgroups, to manage memory instead.
ICACHE.SYS Disk-Cache UtilityDo not use two disk-cache utilities with Windows for Workgroups. It is recommended that you use SMARTDrive, provided with Windows for Workgroups, and remove all references to other disk-cache utilities from your CONFIG.SYS and AUTOEXEC.BAT files. (If ICACHE.SYS is detected, Setup removes it from your CONFIG.SYS file for you.)
IBMCACHE.SYS Disk-Cache UtilityDo not use two disk-cache utilities with Windows for Workgroups. It is recommended that you use SMARTDrive, provided with Windows for Workgroups, and remove all references to other disk-cache utilities from your CONFIG.SYS and AUTOEXEC.BAT files. (If IBMCACHE.SYS is detected, Setup removes it from your CONFIG.SYS file for you.)
Intel(R) Expanded-Memory Emulator (ILIM386.SYS)The ILIM386.SYS expanded-memory emulator, provided with the Intel Inboard(TM)/386 product, is incompatible with Windows for Workgroups. It is recommended that you remove all references to this emulator from your CONFIG.SYS and AUTOEXEC.BAT files before setting up Windows for Workgroups.
|
KBCategory: kbref kbdisplay
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |