Updated IBMTOK.DOS Corrects Error 5736 on 90 MHz PentiumsLast reviewed: May 1, 1997Article ID: Q124124 |
3.10 3.11
WINDOWS
kbfile kbnetwork
The information in this article applies to:
SUMMARYAn updated IBMTOK.DOS file (dated 10/18/94 1:12:42PM, with a file size of 10,112 bytes) is available to correct a timing problem with the original driver. This problem occurs on Pentium 90 MHz (and faster) systems using the IBM Token Ring 16/4 card and a real-mode protocol. After you issue the NET START command, you receive the following error message:
Error 5736: The protocol manager reported a hardware failure.To correct this error, replace your existing IBMTOK.DOS with the updated version. For information about how to obtain the updated driver, refer to the More Information section below. NOTE: Microsoft recommends using protected-mode drivers whenever possible.
MORE INFORMATION
You can find IBMTOKR.EXE (size: 19556 bytes) , a self-extracting file, on the followingservices:
ARTICLE-ID: Q119591 TITLE : How to Obtain Microsoft Support Files from Online Services |
KBCategory: kbfile kbnetwork