  • Microsoft Windows operating system versions 3.0, 3.0a, 3.1, 3.11

For proper operation in Microsoft Windows 386 enhanced mode on the AST VGA Plus card, the following line is required in the [386Enh] section of the SYSTEM.INI file:

   EMMEXCLUDE=C000-C500

This requirement is due to nonstandard ROM mapping by the AST VGA Plus.

If this line is not included, the system may stop responding (hang or lock up) when starting or running Windows in 386 enhanced mode.


KBCategory: kbhw kb3rdparty
KBSubcategory: win30 win31
Additional reference words: 3.00 3.0 3.0a 3.00a hang lock freeze win30
KBHW 3.10 3.11 win31


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.