SUMMARY

Windows for Workgroups does not detect the direct memory access (DMA) channel used by the Etherlink Plus card. To set up the DMA channel for Etherlink, use the Windows Control Panel to manually set the DMA channel during or after installation.

MORE INFORMATION

By default, the Windows for Workgroups Setup program sets the DMA to channel 1, which is the factory default for this card. However, since 3Com recommends DMA channels 5, 6, or 7 for a 16-bit slot (the most common) this setting may not be correct for your card. Therefore, if you have the Etherlink Plus card in a 16-bit slot and have changed your DMA channel to 5, 6, or 7, you must run Control Panel and adjust the DMA Channel setting.


KBCategory: kbnetwork kb3rdparty kbhw
KBSubcategory: wfw wfwg
Additional reference words: 3.10


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: November 21, 1994
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.